Similar Projects
Heating, Ventilation and Air Conditioning Upgrade and Chilled Water Line Installation at the Harris County Credit Union Parking Garage
Bidding
Less than $1,000,000 est. value
Houston, TX 77002

Heating, Ventilation and Air Conditioning Upgrade and Chilled Water Line Replacement at Annex 60
Bidding
Less than $2,000,000 est. value
Houston, TX 77093

HVAC Equipment, Installation, Service, and Related Products
Post-Bid
Houston, TX 77270

Ventilation System at Annex 46
Post-Bid
Houston, TX 77002

Refurbishment of Air Handling Units
Results
$2,600,000 est. value
Houston, TX 77030

HVAC Equipment, Supplies, and Related Items
Term Contract
Results
Baytown, TX

Administration Building Mechanical Renovations
Bidding
$3,000,000 est. value
Houston, TX 77024

Administration Building HVAC Upgrades
Post-Bid
Houston, TX 77015

Chiller Replacement Project
Results
Houston, TX 77000

HVAC Refrigerants
Term Contract
Post-Bid
Houston, TX 77064

Install New Chiller
Results
Houston, TX

Galena Park Middle School HVAC Upgrades
Post-Bid
Galena Park, TX 77547

Replace Two Air Conditioning System
Results
Houston, TX 77040

Air Conditioning, Heating, and Ventilating Equipment, Parts
Post-Bid
Houston, TX 77002

Installation of Heat Exchanger at the North Bayou Central Plant for Harris County
Results
Houston, TX 77002

Last Updated 01/28/2020 07:53 AM
Project Title

UT Health Recreation Center Chiller Replacement

Physical Address View project details and contacts
City, State (County) Houston, TX 77054   (Harris County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $164,998
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Scope Of Work: To replace two (2) Carrier chillers 1. Provide necessary crane (275 ton crane) with lifting plan for removal and replacement. 2. Recover all 134A refrigerant from both machines and recycle in environmentally safe manner. 3. Remove (2) Carrier 30GX Screw chillers and dispose of in an environmentally safe manner. 4. Prefab piping for one chiller in order to get one chiller online in one day. 5. Fabricate remaining chilled water piping. 6. Modify piping to accommodate new chillers piping configuration. 7. Provide two (2) new Carrier 30RBX080 Scroll Chillers. 8. Provide 1st year parts and labor warranty. 9. 3-year micro channel coil parts only warranty. 10. Provide all electrical accessories to make up electrical connections. 11. Reinsulate all piping with 2 inch insulation and .16 Metal jacket.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents