Similar Projects
Remsen Avenue Water Main Upgrade
Infrastructure
Bidding
New Brunswick, NJ 08988

Fire Hydrant Replacement Program
Infrastructure
Bidding
Rockaway, NJ

Force Main Emergency Repair Materials
Post-Bid
Sayreville, NJ 08871

Lake Hiawatha Water Main Replacement Phase 1
Post-Bid
Parsippany, NJ 07054

Brielle Water System Improvements
Results
$1,624,375 est. value
Brielle, NJ 08730

Phase 3 and 4 Water Main Replacement
Results
Less than $5,736,549 est. value
Jersey City, NJ

Water Main Replacement at North Mountain Avenue Stonebridge Road
Post-Bid
Montclair, NJ

East Oak Force Main Rehabilitation Project
Results
Basking Ridge, NJ 07920

Fire Hydrant Replacement Project
Post-Bid
Lakewood, NJ 08201

Insertion Valve Project
Results
$75,450 est. value
Sussex, NJ 07461

Furnish and Deliver "No Lead" Type Brass Water Service Line Fittings
Post-Bid
Clifton, NJ 07011

Exterior and Interior Industrial Utility Construction Services
Term Contract
Results
Hackensack, NJ 07601

West Street Watermain Improvements
Post-Bid
Bordentown, NJ 08505

Seabreeze Way Water Main Replacement project
Results
$203,923 est. value
Keansburg, NJ

Water Main Improvements
Post-Bid
Caldwell, NJ

Last Updated 06/18/2021 09:20 AM
Project Title

South Main Street Water Main Reconstruction

Physical Address View project details and contacts
City, State (County) Woodstown, NJ 08098   (Salem County)
Category(s) Sewer and Water
Sub-Category(s) Water Lines
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The project (base bid w/ alternates) generally entails the installation of approximately 810 LF of 10- inch diameter C900 DR18 PVC water main, restoration of pavement, disturbed striping, concrete sidewalk, concrete curb & gutter. The alternate consists of a jacking and boring an 18-inch diameter steel casing pipe with a 10-inch diameter CLDIP carrier pipe under the existing railroad tracks along with additional associated bends and 10-inch diameter C900 DR18 PVC water main. The proposed water main reconstruction will replace the existing 4-inch ACP water main in South Main Street which will be capped and abandoned in place. All subsurface utility construction will require restoration of all disturbed areas, including trenches, paving, striping, curbing/gutters, and any residential property.

Details

Division 33 - Utilities, Instrumentation and Control for Utilities, Water Utilities, Water Utility Distribution Piping, Water Utility Distribution Equipment, Disinfecting of Water Utility Distribution, Water Utility Storage Tanks.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents