Similar Projects
Boiler Replacement, Occupancy Based Thermostats, Air to Water Heat Pump Installation
Alteration
Bidding
Toms River, NJ

Cooling Tower Replacement at Administration Building 1
Alteration
Bidding
Toms River, NJ 08753

Maintenance and Repair of HVAC Systems
Term Contract
Post-Bid
Bayville, NJ 08721

Industrial Heat Treatment Salt Bath Furnace
Post-Bid
Lakehurst, NJ

Chiller Maintenance Services
Term Contract
Results
Toms River, NJ 08754

Construction of Shorrock Street Water Treatment Plant HVAC Replacement
Results
$275,000 est. value
Lakewood, NJ 08701

Installation of HVAC Equipment Servicing the IT/Server Room
Alteration
Bidding
Toms River, NJ 08753

HVAC and Mechanical Products
Term Contract
Post-Bid

HVAC Upgrades Brackman Middle School
Results
$1,730,000 est. value
Barnegat, NJ 08005

Hydrogen Peroxide Air Filtration & Disinfection Products
Post-Bid

Annual Maintenance for HVAC Systems in Various Buildings
Results
$90,715 est. value
Manahawkin, NJ 08050

HVAC Installation and Drip Pan for STA Barnegat Light
Post-Bid
Barnegat Light, NJ

Municipal Building HVAC Replacement
Results
Bay Head, NJ 08742

Weatherization Energy Conservation Project 2021-2022
Post-Bid

Heating Systems Annual Service and Repairs
Term Contract
Results
Toms River, NJ 08754

Reported 12/30/2021 12:00 AM
Project Title

One (1) 60-Ton Rated Air Cooled Chiller

Physical Address View project details and contacts
City, State (County) Lakehurst, NJ   (Ocean County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Naval Air Warfare Center Aircraft Division (NAWCAD) has a requirement to procure one (1) 60-Ton Rated Air Cooled Chiller, delivered and installed, which will replace a 60-Ton York Chiller, located at the Naval Air Warfare Center Aircraft Division Lakehurst, NJ (NAWCADLKE). This will be a Firm Fixed Price contract, in accordance with the attached Statement of Work (SOW). The resultant contract will be for one (1) 60-Ton Rated Air Cooled Chiller, 460 Volt, 3 Phase. The new chiller will need to be attached to the existing recirculation pump and tank designed system. The pump delivers at least 2.5 gallons per ton of circulation. The chiller unit will have a 3’-5’ of clearance and the existing pad measures 9’6” x 14’. Because this chiller will be replacing an existing chiller, it will need to be sized in accordance with the load it had previously been supplying. In addition, the pad size, clearance requirements and electrical service size also must match the existing York chilling unit. The Government intends to procure the above item through a full and open competition after the exclusion of sources.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Packaged Water Chillers, Centrifugal Water Chillers, Air-Cooled Centrifugal Water Chillers, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents