Similar Projects
Moravian Creek Emergency Repairs
Alteration
Design
$500,000 to $1,000,000 est. value
Wilkesboro, NC

Emergency Watershed Protection - Little Snowbird Debris Removal and Bank Stabilization
Term Contract, Infrastructure
Bidding
NC

Grading, Drainage, and Paving
Infrastructure
Bidding
NC

Elm Street Drainage Project
Post-Bid
Nashville, NC 27856

Emergency Watershed Protection - Gumbo Branch Channel Clearing
Post-Bid
Less than $175,000 est. value
Saint Pauls, NC

DPS - Rockingham Youth Development Center- Grading and Utilities
Results
Rockingham, NC 28379

Falls Lake Bulkhead Repairs
Results
$100,000 to $250,000 est. value
Wake Forest, NC 27587

Carriage Park Entrance Culvert Rehabilitation
Construction
Hendersonville, NC 28791

North Wilkinson Drive Storm Drainage Repairs
Post-Bid
Saint Pauls, NC 28384

Toisnot Park Entrance Improvements
Results
Wilson, NC 27896

Police Department Drainage Improvements
Post-Bid
Gastonia, NC 28052

Broad Street Culvert Replacement
Results
Less than $136,519 est. value
Carrboro, NC 27510

Deep River Pond Maintenance
Term Contract
Post-Bid
High Point, NC 27265

2020 Drainage System Maintenance
Results
Havelock, NC 28532

Aluminum Pipe Arch
Post-Bid
Kinston, NC 28504

Last Updated 04/06/2022 02:39 AM
Project Title

Aluminum Headwall

Physical Address View project details and contacts
City, State (County) Wilson, NC 27893   (Wilson County)
Category(s) Heavy and Highway
Sub-Category(s) Shoreline/Erosion/Drainage
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

1 1 Ea 66” x 45’ x 10 Gage, 3” x 1” Corrugation, Aluminum Pipe With Flagged And Gasketed Joints Fully Welded Inside And Out To 22’ 6” Wide x 10’ Tall Aluminum Structural Plate Headwall Minimum Cover 1.5’ Hl-93 Loading Aluminum Stiffening Rib Bolted To Soil Side Of Wall See Drawing Lucama, Nc Location $ $ 2 1 Ea 95” x 67” x 57’ x 8 Gage, 3” x 1” Corrugation, Aluminum Pipe With Flanged And Gasketed Joints Fully Welded Inside And Out To 22’ 6” Wide x 8’ 5” Tall Aluminum Structural Plate Headwall On Outlet End 14’ + 5’ 6” Wide a 9’ 3” Tall Aluminum Structural Plate Headwall On Inlet End With Wing Wall. Minimum Cover 24” Hl-93 Loading One Roll Of Tensar Tx Geogrid See Drawing Sims, Nc Location

Details

Division 31 - Earthwork, Erosion and Sedimentation Controls.
Division 33 - Utilities, Storm Drainage Utilities, Ponds and Reservoirs.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents