Similar Projects
HVAC Chiller System Preventative Maintenance and Repair - Logan Lab
Alteration
Bidding
Largo, FL 33778

Perdue Boiler Replacement
Alteration
Bidding
$572,000 est. value
Cutler Bay, FL 33157

Ground Transportation Facility GMP 8S.1
Post-Bid
Orlando, FL 32827

Rehabilitation Program - 18807 Autumn Lake Boulevard
Post-Bid
Less than $10,000 est. value
Hudson, FL 34667

Resins for Per Fluorinated Treatment System
Term Contract
Results
Stuart, FL 34994

AAAF #1 Turbine Flush Water Distiller
Results
Less than $35,000 est. value
Jacksonville, FL 32221

Boiler Maintenance, Repair and Related Services
Term Contract
Bidding
FL

Replacement of Existing McQuay Chiller at Pensacola Downtown Public Library
Post-Bid
Pensacola, FL

Stormwater Pond Aeration Maintenance
Results
Fort Myers, FL 33913

Fountain Maintenance at South Cross
Term Contract
Bidding
FL

Mechanical Insulation Services
Post-Bid
FL

Leachate Wastewater Treatment Plant Sand Filter
Results
$60,150 est. value
Punta Gorda, FL 33955

Florida Southwestern State College Campus, Lee, East Yard Chiller Upgrades
Post-Bid
Fort Myers, FL 33919

Water Treatment for Cooling Towers and Closed Loop Systems
Term Contract
Results
Kissimmee, FL 34744

Garage Elevator Repair State #43161 Halifax Health Daytona Beach Campus
Renovation
Post-Bid
Daytona Beach, FL 32116

Reported 03/21/2022 08:44 AM
Project Title

WWTP3 - Blower 5 Motor Replacement

Physical Address View project details and contacts
City, State (County) Winter Haven, FL 33884   (Polk County)
Category(s) Single Trades
Sub-Category(s) Mechanical
Contracting Method
Project Status Abandoned
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Provide new motor and install according to manufacturer’s instructions. Provide new Baldor or Toshiba 350 HP motor and motor to blower coupling (see appendix 1 for details). Provide all necessary tools, labor, equipment, etc. need to remove existing motor and install new motor. Unwire and remove existing motor. Install new blower motor and wire back correctly and check rotation. Replace blower to motor coupling. Contractor will be responsible for aligning blower motor with blower to meet specifications. Contractor is responsible for properly disposing of the old blower motor off site. Contractor will be responsible for obtaining and paying for a qualified Hoffman technician to perform one (1) day start-up and installation verification service of the new blower motor.

Details

Division 11 - Equipment.
Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents