Similar Projects
Last Updated | 02/18/2022 06:53 AM |
Project Title | Guide Rail Repair - Group 2-22/24-Rar1 |
Physical Address | View project details and contacts |
City, State (County) | (Centre, Clinton Counties) |
Category(s) | Heavy and Highway |
Sub-Category(s) | Highway Signs/Guardrails/Barriers |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $500,000 to $999,999 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | For the Improvement of Certain Sections of State Highway in Centre and Clinton County, Various Boroughs and Townships, Commonwealth of Pennsylvania, Group 2-22-rar1. For the Repair or Replacement of Guide Rail, Median Barrier, Bridge Railing, Right-of-way Fence, and Appurtenances Damaged by Traffic and for New Guide Rail Installation for Safety Updates on Various State Routes in Centre and Clinton County 0608-0026 Call 4.000 01 N X Std Emergency Mobilization for Guide Rail Repair and Replacement 0619-0450 Each 2.000 01 N J3 Permanent Impact Attenuating Device, Type Ii, Test Level 3, Flared (Mash) 0619-0459 Each 72.000 01 N J1, J3 Permanent Impact Attenuating Device, Type Ii, Test Level 3, Tangent (Mash) 0619-0470 Each 2.000 01 N J1, J3 Permanent Impact Attenuating Device, Type Ii, Test Level 3 (Energy Absorbing Terminals, Tangent) 0619-0480 Each 2.000 01 N J1, J3 Permanent Impact Attenuating Device, Type Iii, Test Level 3 (Non-energy Absorbing Terminals) 0619-0730 Each 2.000 01 N J3 Permanent Impact Attenuating Device, Type Iv, Test Level 3, (Mash) 0619-0744 Each 2.000 01 N J3 Permanent Impact Attenuating Device, Type V, Test Level 3, Mash, Widths Less Than or Equal to 36 Inches 4619-0744 Each 2.000 01 N Yes J3 Proj Permanent Impact Attenuating Device, Type V, Test Level 3, Mash, Widths Less Than or Equal to 36 Inches Includes Removal of Existing 0620-0010 Each 2.000 01 N J Typical and Alternate Concrete Bridge Barrier Transition Without Inlet Placement 0620-0011 Each 2.000 01 N J Typical and Alternate Concrete Bridge Barrier Transition With Inlet Placement 0620-0012 Each 2.000 01 N J Thrie-beam to Pa Type 10m Bridge Barrier Transition Without Inlet Placement 0620-0015 Each 2.000 01 N J Thrie-beam to Vertical Wall Bridge Barrier Transition 4620-0015 Each 2.000 01 N Yes J Proj Thrie-beam to Vertical Wall Bridge Barrier Transition as Shown on Plans 0620-0400 Each 16.000 01 N J Terminal Section, Single 0620-0402 Each 2.000 01 N J Terminal Section, Bridge Connection 0620-0500 Linear Foot 138.000 01 N J Reset Guide Rail 0620-0503 Linear Foot 5,650.000 01 N C1, J Remove Existing Guide Rail (Contractor's Property) 0620-0525 Each 87.000 01 N J Offset Brackets 0620-0543 Each 2.000 01 N J Guide Rail Strong Post, 7' Length 0620-0544 Each 2.000 01 N J Guide Rail Strong Post, 8' Length 0620-0550 Each 2.000 01 N J S3 X 5.7 Steel I-beam Guide Rail Posts 0620-0551 Each 110.000 01 N J W6 X 9 Steel I-beam Guide Rail Posts 0620-0558 Each 2.000 01 N J 8" X 6" Wood Guide Rail Post, 6' Length 0620-0575 Linear Foot 1,200.000 01 N J Guide Rail Element 0620-0585 Linear Foot 25.000 01 N J Rubbing Rail 0620-0595 Linear Foot 25.000 01 N J Structure Mounted Guide Rail 0620-0862 Each 2.000 01 N J Type 2-s Post Anchorage 0620-0900 Each 2.000 01 N C1, J Remove Concrete Anchorage 0620-1025 Linear Foot 25.000 01 N J Type 2-w Guide Rail 0620-1050 Linear Foot 25.000 01 N J Type 2-wc Guide Rail 0620-1075 Linear Foot 25.000 01 N J Type 2-s Guide Rail 0620-1100 Linear Foot 25.000 01 N J Type 2-sc Guide Rail 4620-1100 Linear Foot 25.000 01 N Yes J Std Type 2-sc Guide Rail With Rubbing Rail and Wooden Offset Brackets 0620-1125 Linear Foot 25.000 01 N J Type 2-scc Guide Rail 0620-1250 Each 2.000 01 N J Type 2 Strong Post End Treatment 0620-1400 Linear Foot 25.000 01 N J Type 2-wcc Guide Rail 0620-1600 Linear Foot 1,920.000 01 N J Type 31-s Guide Rail 0620-1601 Linear Foot 25.000 01 N J Type 31-s Guide Rail With 7' Extra Length Posts 0620-1602 Linear Foot 25.000 01 N J Type 31-s Guide Rail With 8' Extra Length Posts 0620-1625 Linear Foot 25.000 01 N J Type 31-sc Guide Rail 4620-1625 Linear Foot 25.000 01 N Yes J Std Type 31-sc Guide Rail With Rubbing Rail and Wooden Offset Brackets 0620-1626 Linear Foot 25.000 01 N J Type 31-sc Guide Rail With 7' Extra Length Posts 0620-1627 Linear Foot 25.000 01 N J Type 31-sc Guide Rail With 8' Extra Length Posts 0620-1635 Linear Foot 25.000 01 N J Type 31-scc Guide Rail 0620-1637 Linear Foot 25.000 01 N J Type 31-scc Guide Rail With 7' Extra Length Posts 0620-1638 Linear Foot 25.000 01 N J Type 31-scc Guide Rail With 8' Extra Length Posts 0620-1640 Linear Foot 25.000 01 N J Type 31-sm Guide Rail 0620-1645 Linear Foot 25.000 01 N J Curved W-beam Guide Rail at Intersections 0620-1650 Each 2.000 01 N J Type 31-strong Post End Treatment 0620-1660 Each 2.000 01 N J Type 31-strong Post Anchor Terminal 0620-1670 Each 8.000 01 N J Type 31-strong Post in-line Anchor 0690-0001 Dollar 2.000 $1.00 $2.00 01 Y X Internal Facilitation 0901-0240 Square Foot 100.000 01 N Q, R Additional Traffic Control Signs 0937-0104 Each 55.000 01 N J, R Guide Rail Mounted Delineator Type B, (Y/b) 0937-0106 Each 7.000 01 N J, R Guide Rail Mounted Delineator Type B, (W/b) 0937-0112 Each 2.000 01 N J, R Guide Rail Mounted Delineator Type D, (Y/b) 0937-0113 Each 13.000 01 N J, R Guide Rail Mounted Delineator Type D, (W/b) 0937-0333 Each 24.000 01 N R Flexible Delineator Post, Ground-mount Type Gm-2, Yellow Post With Yellow/blank Sheeting 0937-0339 Each 37.000 01 N R Flexible Delineator Post, Ground-mount Type Gm-2, Red Post With White/blank Sheeting 0937-0340 Each 4.000 01 N R Flexible Delineator Post, Ground-mount Type Gm-2, Red Post With Yellow/blank Sheeting 9000-0001 Call 4.000 01 N Q Proj Maintenance and Protection of Traffic During Construction 9000-0025 Call 4.000 01 N X Std Mobilization for Guide Rail Repair and Replacement 9000-0036 Each 2.000 01 N J Proj Realign Existing Guide Rail Posts (All Types) 9000-0040 Each 20.000 01 N J Proj End Treatment Update/conversion 9000-0060 Each 2.000 01 N J Proj High-tension Cable Median Barrier Foundation 9000-0061 Each 3.000 01 N J Proj High-tension Cable Median Barrier Post 9000-0062 Linear Foot 2,313.000 01 N J Proj Re-tensioning of Existing High-tension Cable 9000-0063 Each 2.000 01 N J Proj High-tension Cable Median Barrier Splice Assemblies 9000-0064 Each 2.000 01 N J Proj High-tension Cable Median Barrier End Treatment 9000-0171 Dollar 50,000.000 $1.00 $50,000.00 01 Y J Proj Unforeseen Time and Material 9000-0187 Each 2.000 01 N J Proj High Tension Cable Guide Rail Posts 9000-0300 Dollar 80.000 $1.00 $80.00 01 Y J Proj Reset Height and Re-tension Htc Guide Rail 9000-0500 Dollar 1,500.000 $1.00 $1,500.00 01 Y J Proj Unforeseen Guide Rail Repairs 9000-0576 Linear Foot 25.000 01 N J Proj Radius Guide Rail Element 9000-0577 Each 2.000 01 N J Proj Back-up Plates for Type 2-w Guide Rail 9000-0590 Linear Foot 113.000 01 N J Proj Height Adjustment of Existing Guide Rail 9000-0862 Each 2.000 01 N J Proj Type 2-s Post Anchorage With 1 Radius Panel 9000-1100 Linear Foot 25.000 01 N J Proj |
||||
Details |
|
||||
Bidder's List | View project details and contacts | ||||
Prospective Bidders | View project details and contacts | ||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |