Similar Projects
Last Updated | 01/08/2020 09:09 AM |
Project Title | Riverbanks Zoo and Garden Electrical Services |
Physical Address | View project details and contacts |
City, State (County) | Columbia, SC (Richland County) |
Category(s) | Single Trades |
Sub-Category(s) | Electric |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $46,500 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Electrical contractor to install a 200-amp service and run 32 20-amp circuits in conduit to duplex or quad receptacles located along a pathway covering the project site. Each receptacle will be mounted on a wooden 4 by 4 that is 18 inches in the ground and 30 inches above grade to the top of the post. A duplex receptacle with a weather proof cover will be attached and a plastic tool box (specifications attached) will be altered to fit over the assembly and attached to the post to ensure the connections are not impacted by rodents or rain. Panel: outdoor rated Square D 200-amp, 208 sized so that there are at least 6 spare slots left in the panel once the listed circuits are in. Mount panel on Unistrut and 4 by 4 s next to power pole. Contractor responsible for permit and materials needed to be ready for connection to SCE and G supplied power from the existing power pole. |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |