Similar Projects
MATOC IDIQ for Control Systems Installations at Hydroelectric Facilities for The U.S. Army Corps of Engineers, South Atlantic Division
Term Contract
Bidding
Less than $20,000,000 est. value

Generators for State Parks
Alteration
Bidding
Charleston, SC 29407

Indefinite Delivery Contract - Electrical Services
Post-Bid
Charleston, SC 29401

MUSC Walton Research Automatic Transfer Switch Replacement
Post-Bid
$200,000 to $400,000 est. value
Charleston, SC 29425

Generator Platforms for 55 Center St and 510 E Erie
Results
Less than $39,500 est. value
Folly Beach, SC 29439

Light Bulbs for Holiday Festival of Lights
Term Contract
Results
Charleston, SC 29412

Craig Mechanical Room Renovation
Post-Bid
$700,000 to $800,000 est. value
Charleston, SC 29424

Replace UPS Power System
Results
Charleston, SC 29412

LRC Gate Repair K5510
Post-Bid

Generator Preventive and Predictive Maintenance and Repair
Results
North Charleston, SC 29405

Remove and Install New Westerbeke Diesel Generators
Post-Bid
Charleston, SC 29412

Stoney Field Mechanical and Electrical Improvements
Results
$300,000 to $350,000 est. value
Charleston, SC 29401

Hanger Fans
Term Contract
Post-Bid

J061-- UPS Battery Replacement
Results
Charleston, SC 29401

TOC -Electrical Contracting Services
Alteration
Post-Bid
Charleston, SC

Last Updated 10/28/2021 03:58 PM
Project Title

Electrical Panel and Electrical Circuits

Physical Address View project details and contacts
City, State (County) Charleston, SC 29412   (Charleston County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $25,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

This project has the following major components. Add one 120V, 20 Amp circuit for the new freezer from the panel to exterior junction box. Provide one (1) 40A and one (1) 30A 3 phase 480 volt circuit from Panel H1B Install new disconnect rated plug connectors or equivalent to *see attachment (1) Provide Core drilled holes for access to the electrical panels. All conduit to be PVC in crawlspace and Rigid where exposed. Plug all unused core drill holes and secure all conduit and wires with fasteners. Test and verify with Government Technical POC and facility personnel that all circuits provide above stated amperage and voltage on demand

Details

Division 26 - Electrical, Switchboards and Panelboards, Surge Protective Devices, Surge Protective Devices for Low-Voltage Electrical Power Circuitsrical Power Circuits.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents