Similar Projects
Metal Panel Wall Installation
Alteration
Bidding
$200,000 est. value
Newnan, GA 30265

Roofing MACC
Post-Bid

Roofing MACC
Post-Bid

MATOC - Army Reserve National Roofing Program (NRP)
Results
Less than $95,000,000 est. value

MATOC - Army Reserve National Roofing Program (NRP)
Results
Less than $95,000,000 est. value

Andrews Roof Replacement
Results
Less than $359,295 est. value
Brunswick, GA 31520

Roof Recoat of 426 Canton Highway
Results
Cumming, GA 30040

CM Manager at Risk Historic Courthouse Slate Roof Replacement and Exterior Remediation Project
Alteration
Results
Lawrenceville, GA 30046

Justice Center Reroofing
Alteration
Results
Newnan, GA 30263

Reported 12/22/2021 12:00 AM
Project Title

Roof Repair Project Milledgeville Fire Rescue Station 1

Physical Address View project details and contacts
City, State (County) Milledgeville, GA 31061   (Baldwin County)
Category(s) Single Trades
Sub-Category(s) Roofing
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Scope: Protect the grounds and surrounding area from damage during work. Remove existing shingle roof and dispose of all debris. There are currently four (4) low profile attics vents and one (1) low profile power ventilation that will be eliminated. Install self- venting roof vents in place of existing vents. (The new ridge condition is self-venting therefore the low profile attic vents are not required). Install two (2) new gas flue vent pipes works needs to be coordinated with the HVAC contractor. Eliminate the gas flue vent next to the lower engine room next to the short antenna. Replace approximately 40 lineal feet of deteriorating l"xlO" fascia. Afterwards replace caulk, prime and new paint to fascia, paint to be provided by owner. Replace any additional deteriorating wood and roof decking as needed. Install high temperature rated synthetic underlayment over entire roof surface. Custom fabricate and install new 1½" standing seam metal roof system using 24 gauge Kynar finished steel. Panels may be fabricated on-site using roll forming equipment. The Fire Department shall have choice of colors from the standard color category. Flash electric weather heads and plumbing pipe vents using commercial grade EPDM flashings. Custom fabricate and install new in-wall counter flashing where metal roof meets the vehicle bay brick wall. Flashing will be cut into the brick mortar joints and sealed as required. Remove and dispose of all debris generated by our scope of work. Includes five (5) year workmanship warranty against roof leaks from contractor and metal manufacturer’s thirty-five (35) year metal warranty. Roof overhang needs to be 2” to accommodate gutters. Contractors will be required to measure the work site.

Details

Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents