Similar Projects
Construction of the 193rd and 51st Waterline Relocation
Infrastructure
Bidding
Broken Arrow, OK

Utility Repairs and Maintenance for OCAT
Infrastructure
Bidding
$400,000 est. value
Bethany, Oklahoma City, OK 73159

Section A Waterline and Section B Stand Pipe Painting and Rehabilitation
Infrastructure
Post-Bid
Taft, OK

W912bv21r0047-Presolicitation Notice (Sources Sought)- Bureau of Reclamation Waterline Relocation, Tinker AFB
Term Contract
Post-Bid
$5,000,000 to $10,000,000 est. value
Oklahoma City, OK 73145

Water Line Replacement
Results
McAlester, OK 74501

100-200 Block East Garriott Road Waterline Relocation
Results
Enid, OK

Guthrie Fire Hydrant Replacements
Infrastructure
Bidding
Guthrie, OK

AMI Electric and Water Meter Installation
Infrastructure
Post-Bid
Edmond, OK

4800-5300 Blocks Venture Road Waterline Improvement
Results
$144,490 est. value
Enid, OK

Leona Mitchell BLVD Water Main and Improvements
Infrastructure
Bidding
Enid, OK

New Splash Pad at the Atoka Sports Complex
New Construction, Infrastructure
Post-Bid
Less than $250,000 est. value
Atoka, OK 74525

1500-2500 Block of North Cleveland Street Waterline Relocation
Results
Enid, OK 73703

Water System Improvements
Infrastructure
Bidding
$1,250,000 to $1,330,000 est. value
Elk City, OK 73644

Kunkle Valve Replacement
Alteration
Post-Bid
Norman, OK 73019

Operation, Maintenance and Repair Services
Term Contract
Results
Oklahoma City, OK

Reported 03/21/2022 08:12 AM
Project Title

DWSRF Project 1 Water Tower Controls and Hickory Street Distribution System Improvements

Physical Address View project details and contacts
City, State (County) McAlester, OK 74501   (Pittsburg County)
Category(s) Sewer and Water
Sub-Category(s) Water Lines
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

DWSRF Project 1 Water Tower Controls and Hickory Street Distribution System Improvements consisting of Section A - Revise Tower Controls to the water storage system and Section B - Installation of approximately 3200’ of 24” PVC, 1400’ of 18” PVC, 5200’ of 16” PVC, 20’ of 14” PVC, 50’ of 8” PVC, 540’ of 6” PVC and 1000’ of 2” PVC main water line.

Details

Division 33 - Utilities, Instrumentation and Control for Utilities, Water Utilities, Water Utility Distribution Piping, Water Utility Distribution Equipment, Disinfecting of Water Utility Distribution, Water Utility Storage Tanks.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents