Similar Projects
Last Updated | 10/27/2021 03:54 PM |
Project Title | Ballistic Guard Shack Level III |
Physical Address | View project details and contacts |
City, State (County) | Mobile, AL (Mobile County) |
Category(s) | Government/Public |
Sub-Category(s) | Military Facility |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The US Coast Guard has a requirement for a 8'x12' Ballistic Level III Guard Shack. Specifications as follows; 1. All material used for exterior walls: 1/4" Arm alloy 500 Ballistic Steel Plates, UL 752 Level 3, fully welded. 2. Two (2) 36" x 84" Bullet Resistant UL 752 Level 3 hollow metal Half Lite Sliding doors, Doors to be glazed with UL 752 Level 3 clad polycarbonate glazing. Door gear included. 3. Windows UL 752 Level 3 bullet resistant, tinted glazing, and fixed clad poly-carbonate glass mounted against the ballistic walls, 36" tall, all around. 4. Contractor shall ensure that all US Coast Guard Standards, UL325 and Federal, State, and Local safety requirements are met. 5. 3" structural steel tubing frame, all welded steel construction with 1/8" steel tread plate floor, floor to be supported by interior structural steel tubing joist. 6. Insulation: Walls, roof, floor R-18 7. Exterior wall panels factory finished, UL 752 Level 3 bullet resistant protection exterior face, 16- gauge heavy duty steel interior, panels galvanized and mechanically fastened. 8. Ceiling finish with 16-gauge heavy duty steel, galvanized and mechanically fastened to provide smooth flat interior 9. Roof finish with 11-gauge heavy duty steel, galvanized and welded to provide smooth flat exterior 10. Four (4) Lifting rings 11. 3" Overhang on all four sides of the roof 12. Brackets for anchoring to platform 13. One (1) Painted Steel counter (18" deep) 14. All electrical consists of 12-gauge minimum copper wiring in 1/2" minimum EMT surface mounted and attached to surface mounted 4x4 box 15. One (1) Circuit Breaker Box, 125 Amp, 12 Spaces with 4 Circuits 16. Two (2) single pole switches 17. Two (2) 115V duplex receptacles 18. One (1) 220V receptacle 19. Two (2) Interior LED Light Fixtures 20. Three (3) Exterior LED Light Fixtures 21. One (1) CAT5E Computer Jack Set (2) w/Junction Box 22. One (1) Minisplit HVAC Unit with 12,000 BTU Cooling and Heating, 220V |
||||||||||||||||||||||||||||||||||||
Details | Military Facility, New Construction.
|
||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |