Similar Projects
Last Updated | 01/18/2022 08:32 AM |
Project Title | Inspection, Testing, and Repairs of Aboveground and Underground Storage Tanks, NSA |
Physical Address | View project details and contacts |
City, State (County) | Crane, IN (Martin County) |
Category(s) | Sewer and Water |
Sub-Category(s) | Storage/Water Tanks |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The contractor shall provide all labor, supplies, materials, equipment, transportation, facilities, utilities, supervision and management; unless otherwise specified; required for Aboveground and Underground Storage Tank Inspection, Testing, and Repair Services. Services will include, but are not limited to, Steel Tank Institute (STI) annual inspections, tank leak tightness testing, cathodic protection testing, leak detection system calibration/testing, storage tank equipment and fuel servicing equipment installation/repair, and incidental work performed at Naval Support Activity (NSA), Crane, IN and Glendora Lake Test Facility (located approximately 45 miles northwest of NSA Crane in Sullivan County, IN). Recurring services will include approximately five (5) annual Tank Leak Tightness Tests (40 CFR 280 Tanks), three (3) annual Tank Leak Tightness Tests (40 CFR 264 Tanks), four (4) annual Cathodic Protection Tests, three (3) annual Veeder Root Tests, one (1) annual Pollulert Test, thirty-eight (38) annual STI-SP001 Inspections (55 gal – 9,999 gal ASTs), eight (8) annual STI-SP001 Inspections (10,000 gal – 25,000 gal ASTs), one (1) annual STI-SP001 Fueling Station Inspection (six (6) total tanks), five (5) annual Operation & Maintenance Walkthrough Inspections, five (5) annual Spill Prevention & Overfill Prevention Equipment tests, five (5) annual Spill Prevention (containment sump for tank pump) Tests, and five (5) annual Spill Prevention (dispenser containment sump) Tests. Recurring services will also include monthly inspection of five (5) regulated USTs, three (3) explosive contaminated USTs, fifty-one (51) 40 CFR 112 ASTs, one (1) 40 CFR 112 AST at Glendora Test Facility, twenty-one (21) portable container locations, five (5) mobile refuel/pump trucks, and Storage Tank Program Meetings and Assist Visits (meetings are bi-monthly). Non-recurring services will include tank leak tightness testing of 40 CFR 112 USTs (6,000 gal – 30,000 gal), generator base tank pressure testing, AST pressure testing (55 gal – 9,999 gal), AST pressure testing (10,000 gal – 25,000 gal), STI-SP001 formal external inspections, and additional labor, materials, and equipment for repairs not covered within other ELINs. A Steel Tank Institute (STI) Certified AST Inspector must perform all tank inspections, testing, and repair services. Level 2 or Level 3 certified personnel must complete the Veeder Root inspection, testing, and repair. |
||||||||||||||||
Details |
|
||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |