Similar Projects
Utility Monitoring and Control Systems
Post-Bid
Less than $2,100,000,000 est. value

Taconic Furnace Maintenance and Emergency Service
Term Contract
Post-Bid

Repair Heating / Ventilation Controls at Kingston Armory
Results
$275,000 to $550,000 est. value
Kingston, NY

Provide Energy Efficient Retrofit at State Armory
Results
$750,000 to $1,500,000 est. value
Kingston, NY

Replace MEP Systems at Lecture Center at SUNY New Paltz
Post-Bid
New Paltz, NY 12561

IDIQ JOC HVAC Phase 2
Results
Less than $500,000 est. value

Heating Contractors
Term Contract
Post-Bid
Kingston, NY 12401

HVAC Upgrade for Public Works Building
Term Contract
Results
Kingston, NY 12401

Water Cooled Vapor Compression and Vapor Absorption Chiller Preventative Maintenance and Repair Services
Term Contract
Post-Bid
Kingston, Poughkeepsie, Suffern, Valhalla, NY

Install Ductless Air Conditioner
Results
Less than $25,000 est. value
Saugerties, NY 12477

HVAC & Refrigeration Replacement / Maintenance
Term Contract
Post-Bid

Upgrade Lecture Center Mechanical Systems at SUNY New Paltz
Results
$5,000,000 to $10,000,000 est. value
New Paltz, NY 12561

HVAC Pneumatic Control Systems, Maintenance/Service - Campus-wide 2019
Post-Bid
New Paltz, NY 12561

HVAC Replacement for SUNY Ulster Burroughs Hall
Term Contract
Results
Stone Ridge, NY 12484

Replacement of Roof Top HVAC Units at Development Court
Term Contract
Post-Bid
Kingston, NY 12402

Last Updated 01/24/2019 10:17 AM
Project Title

Replacement Rooftop HVAC Units

Physical Address View project details and contacts
City, State (County) Kingston, NY   (Ulster County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description This is a bid to provide and install four (4) replacement HVAC units at 300 Foxhall Ave, Kingston. The work will consist of replacing the units with Daiken, or equal, natural gas units as specified. All costs associated with any modifications required to existing ductwork shall be included in the vendor's proposal. All replacement units offered must meet ENERGY STAR* qualifications. EXISTING UNITS to be removed; RTU #1 McQuay Model # RRS025BA, Serial # 37C00293 08. RTU #2 McQuay Model # RRS025BA, Serial # 37C00294 08. RTU #3 McQuay Model # RRS025BA, Serial # 37C00295 08. RTU #4 Lenox Model # GCS24-953-200-1Y Serial #27B 0311601 SPECIFIC UNITS TO BE INSTALLED IN PLACE OF EXISTING, OR EQUAL - See attached Item Summary for each unit RTU-1 (Warehouse) Daikin MAV-II 11000 CFM Space Control HGRH Model # MPS026G RTU-2 (Warehouse) Daikin MAV-II 12000 CFM Space Control HGRH Model # MPS030F RTU-3 (Office) Daikin MAV-II 11000 CFM VAV Model # MPS026G RTU-4 (Office) Daikin 3000 CFM VAV Model # DPS010A
Details
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents