Annual Inspection of Portable Fire Extinguishers (Qns/si Focus)
Term Contract
Bidding
New York, NY

Inspection, Testing and Central Station Monitoring of Fire Alarm-BK
Alteration
Post-Bid
New York, NY

Inspection, Testing and Central Station Monitoring of Fire Alarm-MN
Alteration
Post-Bid
New York, NY

Inspection, Maintenance and Repair of Fire Alarm Systems at Various Agency Facilities
Term Contract
Results

Inspection, Maintenance and Repair of Fire Alarm Systems at Various Agency Facilities
Term Contract
Results

Inspection, Testing and Central Station Monitoring of Fire Alarm-BX
Alteration
Post-Bid
New York, NY

OPWDD Statewide Fire Alarm Systems and Fire Sprinkler Systems Inspection, Testing, Maintenance, Remedial Repairs, Emergency Service Calls and Repairs
Term Contract
Results

Requirements Contract for Testing and Cleaning of Interior Fire Alarm Systems
Alteration
Post-Bid
Brooklyn, NY

MCRC Fire Protection System & Gates Upgrade
Term Contract
Results
$1,000,000 to $5,000,000 est. value
Brooklyn, NY

Surveying, Testing, Repair and Alterations of Fire Alarm Systems - Brooklyn
Alteration
Post-Bid
Brooklyn, NY

Inspection Testing and Maintenance of Special Hazard Fire Suppression Systems
Alteration
Results
New York, NY 10065

Surveying, Testing, Repair and Alterations of Fire Alarm Systems - Manhattan
Alteration
Post-Bid
Manhattan, NY

HS 485 Fire Sprinkler System
Alteration
Results
$1,000,001 to $1,500,000 est. value
New York, NY 10023

Surveying, Testing, Repair and Alterations of Fire Alarm Systems - Queens/Staten Island
Alteration
Post-Bid
Queens Village, Staten Island, NY

Maintenance and Repair of Fire Safety Systems in the Bronx, Manhattan, and Queens
Alteration
Results
Bronx, Manhattan, NY

Reported 06/09/2022 12:00 AM
Project Title

C40853 Design-Build Services for Central Alarm Monitoring System (CAMS) and Fire Alarm System and Sprinklers Replacement

Physical Address View project details and contacts
City, State (County) New York, NY 10019 (Kings, New York, Queens Counties)
Category(s) Single Trades
Sub-Category(s) Fire Protection
Contracting Method Competitive Bids.
Project Status Request for Proposals (RFPs), Construction Start Expected February 2023
Bids Due View project details and contacts
Estimated Value $50,000,000 to $100,000,000
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The existing CAMS headend systems will be replaced at the two (2) locations where the current CAMS headend systems are located: the primary location at Rail Control Center (345 West 54th Street, Manhattan), and the backup location at 130 Livingston Street, Brooklyn. An additional three (3) locations will also require hardware, including workstations, for a total of five (5) workstations at the locations listed below: # Location 1 RCC (354 West 54 th Street) 2 130 Livingston Street, Brooklyn NY 3 29-76 northern Blvd. (EMD Facility) 4 2020 Broadway EMD Facility 5 2 Broadway (11th Floor) Fire alarm and sprinkler systems will also be replaced under this Project in the twenty-one (21) subway stations and other MTA-facilities identified in the table below. This portion of the Work includes new fire alarm control panels, as well as remote annunciators, initiating devices, notification devices, and other equipment, including but not limited to, solenoid valves, tamper and water switches, water sensors, and heat tracers. Equipment will be installed within HVAC, vertical transportation, and other equipment/locations, and will be commercially proven and code compliant replacements.

Details

Division 21 - Fire Suppression.
Division 28 - Electronic Safety and Security, Fire Detection and Alarm.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents