Similar Projects
Filbin Creek and Noisette Ventilation Upgrades
Bidding
North Charleston, SC 29405

SEI Air Handlers 1-6 Replacement
Post-Bid
$575,000 to $625,000 est. value
Charleston, SC 29425

Hollings Cancer Center 2nd Floor Pharmacy HVAC Installation
Post-Bid
$100,000 to $250,000 est. value
Charleston, SC 29425

Back-up HVAC System for Server Room
Results
Charleston, SC 29415

Hood and Exhaust Cleaning
Results
Less than $25,264 est. value
North Charleston, SC

Basic Science Building AHU-3 and AHU-5 Replacement
Post-Bid
$1,000,000 to $1,100,000 est. value
Charleston, SC 29425

Hollywood Site HVAC Services 2019
Results
Hollywood, SC 29449

Thurmond Gazes Research Building Humidifier Replacement
Post-Bid
$600,000 to $700,000 est. value
Charleston, SC 29425

Installation of 32 Owner Furnished Natural Gas Tube Type Heaters at Market Shed C
Results
$75,000 to $100,000 est. value
Charleston, SC 29401

Psych Institute Chiller 1 Replacement
Post-Bid
$1,000,000 to $2,000,000 est. value
Charleston, SC 29425

Maintenance of Heating Ventilating and Air Conditioning Systems
Results
North Charleston, SC 29419

Repair HVAC Dormitory Building 2405 and 2406
Post-Bid
$1,000,000 to $5,000,000 est. value
Charleston, SC 29404

Replacement High Pressure Breathing Air Compressor System
Results
Less than $60,000 est. value
Hollywood, SC 29449

Chiller Replacement at Lightsey Center
Post-Bid
Charleston, SC 29401

Roof and Mechanical Unit Replacement
Results
Folly Beach, SC 29439

Reported 09/16/2020 12:00 AM
Project Title

Welding Fume and Dust Extraction System

Physical Address View project details and contacts
City, State (County) SC   (Charleston County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Five Air Booths; Self-contained; Must not require duct work, exterior exhausting, or connection to compressed air; Air Flow: 2,500 CFM@ 2.5” tsp; Sound: 74 dBA at Operator; Amperage: 17.2 FLA @ 120V- Motor and Lights; 15.0 FLA @ 120V- GFCI Circuit; Interior Height: 8’; Interior Width: 4’ to 6’; Interior Depth: 4’ to 6’

Details

Division 02 - Existing Conditions, Existing Material Assessment, Existing Metals Assessment, Welding Investigations.
Division 13 - Special Construction, Fabricated Engineered Structures, Fabricated Structures, Fabricated Control Booths.
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents