Last Updated | 07/06/2020 12:16 PM |
Project Title | Communications Shelter Purchase 2020 |
Physical Address | View project details and contacts |
City, State (County) | Jacksonville, FL (Duval County) |
Category(s) | Commercial |
Sub-Category(s) | Communication Building |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Bids for 2 Communications Shelter sites. Construction - Concrete Size nominal 10' wide exterior x nominal 16' long exterior x nominal 9'2" high interior, one room concrete shelter The structural loads of the proposed concrete shelter are as follows: 200 pounds per square foot distributed floor loading while on foundation 125 pounds per square foot distributed floor loading while lifting 100 pounds per square foot distributed roof load 150 mph wind load Seismic Zone 4 Lightweight concrete weight to be less than 100 lbs./cu.ft. Aggregate to be homogenous; no seeding of aggregate Preliminary drawings to be provided 12-15 working days after receipt of purchase order Shelter to be approved and labeled through the Florida Department of Community Affairs All building panels (wall-to-wall, roof-to-wall, and wall-to-floor) shall be constructed with step joints to prevent water intrusion All building panel connections shall be accomplished by a welded connection by certified welders. Bolted panel connections are not acceptable Building lifting provisions shall be integral to the shelter floor. Bolt-on lifting eyes or lifting provisions from the shelter walls are not acceptable The proposed shelter walls, roof, and floor shall be a minimum of 4” thick lightweight concrete (concrete weight to be less than 100 lbs./cu.ft.) The proposed shelter walls will provide a two hour fire rating The walls will be insulated with hardboard insulation, total wall is R-19 The ceiling will be insulated with hardboard insulation, total ceiling is R-38 The interior walls and ceiling will be sheathed with white Nupoly board Exposed aggregate exterior The proposed shelter walls are capable of stopping 30.06 rifle fire per UL752 requirements. Unless otherwise specified, the shelter door is not bullet resistant Light colored industrial grade vinyl tile floor covering One (1) 36" wide x 84" high Florida approved steel exterior door of fully insulated construction with stainless steel ball-bearing tamper-proof hinges, latch guard, security viewer, passage style lever handle, Florida approved Mortise deadbolt lockset and fiberglass weather hood One (1) hydraulic door closer |
||||||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |