Similar Projects
Last Updated | 12/29/2021 09:33 AM |
Project Title | Lighting Repairs and Improvements in the Prudential Tunnel |
Physical Address | View project details and contacts |
City, State (County) | Boston, MA (Norfolk County) |
Category(s) | Outdoor Lighting |
Sub-Category(s) | Roadway Lighting |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $32,266,395 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | "1.000","Ls","Schedule of Operations - Fixed Price $132500","100." "1.000","Ls","Fan Chamber #1","100.91" "1054.000","Sf","Tunnel Wall Repairs Spalls S1","100.921" "2858.000","Sf","Tunnel Wall Repairs Spalls S2, S3, S4","100.922" "365.000","Ft","Tunnel Wall Repairs Cracks","100.93" "80.000","Ea","Tunnel Stanchions Foundation Anchors","100.94" "1.000","Ls","Conduit and Luminaire Supports","100.95" "31.000","Mo","Engineers Field Office and Equipment (Type a)","740." "1.000","Ls","Mobilization","748." "16170.000","Ft","3/4 Inch 316 Ss Lfmc","804.151" "35200.000","Ft","2 Inch Phenolic Conduit","804.152" "44000.000","Ft","3 Inch Phenolic Conduit","804.153" "6600.000","Ft","1 Inch Electrical Conduit Type Rm - Galvanized Steel","806.1" "495.000","Ft","2 Inch Electrical Conduit Type Rm - Galvanized Steel","806.2" "1980.000","Ft","3 Inch Electrical Conduit Type Rm - Galvanized Steel","806.3" "550.000","Ft","4 Inch Electrical Conduit Type Rm - Galvanized Steel","806.4" "650.000","Ea","20 Inch X 20 Inch X 6 Inch Nema 4x 316ss Junction Box (Tunnel Area Normal Lighting)","811.580" "375.000","Ea","20 Inch X 20 Inch X 6 Inch Nema 4x 316ss Junction Box (Tunnel Area Standby Lighting)","811.581" "90.000","Ea","16 Inch X 16 Inch X 6 Inch Nema 4x 316ss Junction Box (Ramp Area Normal Lighting)","811.590" "75.000","Ea","16 Inch X 16 Inch X 6 Inch Nema 4x 316ss Junction Box (Ramp Area Standby Lighting)","811.591" "40.000","Ea","24 Inch X 18 Inch X 10 Inch Nema 4x 316ss Normal Lighting Pull Box","811.601" "35.000","Ea","24 Inch X 18 Inch X 10 Inch Nema 4x 316ss Standby Lighting Pull Box","811.602" "63450.000","Ft","Wire Type Xhhw-2 Awg #10","813.031" "304000.000","Ft","Wire Type Xhhw-2 Awg #6","813.032" "992000.000","Ft","Wire Type Xhhw-2 Awg #4","813.033" "2500.000","Ft","#600 Kcmil Xhhw-2 Conductors","813.034" "176000.000","Ft","2 Hour Fire Rated Cables - No. 6","813.132" "152000.000","Ft","2 Hour Fire Rated Cables - No. 4","813.133" "5400.000","Ft","2 Hour Fire Rated 3/c Awg#12 Mc Cable for Whips","813.134" "9000.000","Ft","#250 Kcmil Rhw-2 Conductors","813.135" "748.000","Ea","Tunnel Lighting Luminaire Led 495 Watt","823.036" "890.000","Ea","Tunnel Lighting Luminaire Led 182 Watt","823.037" "38.000","Ea","Tunnel Lighting Luminaire 495 Watt (Spares)","823.038" "44.000","Ea","Tunnel Lighting Luminaire 182 Watt (Spares)","823.039" "1.000","Ls","Tunnel Lighting Control System","823.055" "1.000","Ls","Tunnel Lighting System and Mounting Hardware Removed","823.071" "500.000","Day","Traffic Cones for Traffic Management","851.1" "1716.000","Sf","Safety Signing for Traffic Management","852." "3120.000","Ft","Temporary Vehicular Travel Lane Tunnel Lighting","853.9" "500.000","Day","Arrow Board","856." "23850.000","Day","Reflectorized Drum","859." "900.000","Day","Reflectorized Drums With Sequential Flashing Warning Lights","859.1" "1.000","Ls","Basic Materials and Methods","998.050" "1.000","Ls","Low Voltage Transformers","998.270" "1.000","Ls","Grounding and Bonding for Electrical Systems","998.450" "7.000","Ea","Panelboards","998.470" "1.000","Ls","Ups and Battery Systems","998.610" "1.000","Ls","Ups Battery Equipment","998.630" |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |