Similar Projects
Replace Expansion Joints, East and West Arterial Roadways - Electrical
Alteration
Bidding
$100,000 to $250,000 est. value
Albany, NY 12242

Replace Quarry Tile Floor, Kitchen and Dishwash Area, Building 12 - Electrical
Alteration
Bidding
$25,000 to $50,000 est. value
Ogdensburg, NY 13669

Occasional Electrical Repair 2020 - 2021
Term Contract
Post-Bid
Voorheesville, NY 12186

CEC SF6 Circuit Breakers
Term Contract
Post-Bid
Marcy, NY 13403

J--Testing & PM for Generator Systems - Buffalo/Batavia
Results
$100,000 to $250,000 est. value
Batavia, Buffalo, NY 14215

J--Testing & PM for Generator Systems - Buffalo/Batavia
Results
$100,000 to $250,000 est. value
Batavia, Buffalo, NY 14215

General Electrical Services
Alteration
Bidding
Ithaca, NY

Comprehensive Electrical Work
Post-Bid
Port Chester, NY 10573

Welcome Center Backup Generator
Results
Less than $138,800 est. value
Grafton, NY 12082

Rehabilitate Armory and Storage Building - Electrical Work
Alteration
Bidding
Bronx, NY 10468

Electrical Repair Work
Post-Bid
Albany, NY 12207

CMAC - Emergency Lighting
Results
Canandaigua, NY 14424

Rhodes Hall UPS Replacement
Post-Bid
$750,000 to $775,000 est. value
Ithaca, NY 14853

Electrical Improvements - Five Points Transfer Station
Results
Little Valley, NY 14755

Standby Generator
Post-Bid
Rodman, NY 13682

Last Updated 09/27/2021 08:45 AM
Project Title

Purchase and Installation of Generator for the Pine Street Pump Station

Physical Address View project details and contacts
City, State (County) Endicott, NY   (Broome County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Provide 125KW power @ 240VAC 3PH Be able to supply 375 amps @ 240VAC Be diesel fired Fuel storage tank to provide 24 hours of running Have an outside disconnect and Emergency Stop Have remote control panel to start generator from inside Automatically do a weekly exercise Cold weather package so generator is able to run in winter Supplier must: Set and attach new generator on existing pad at Pine Street Location Install appropriate sized wire from generator to existing manual transfer switch Install operator control panel near manual transfer switch Set weekly exercise for Wednesday at noon Provide certified startup of generator so as not to void manufacturer warranty Provide winter stabilized tank of fuel.

Details

Division 26 - Electrical, Packaged Generator Assemblies.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents