Similar Projects
Belle Glade Senior Center
Post-Bid
Belle Glade, FL 33430

Windows Replacement Bonnie Dale Villas
Post-Bid
New Port Richey, FL 34653

J--PM for Automatic Doors
Results
Orlando, FL 32827

Public Works Administration Building Wind Retrofit
Results
Less than $260,000 est. value
Sanford, FL 32773

Hurricane Shelter Retrofit Barriers Project
Term Contract
Post-Bid
Less than $1,200,000 est. value
Clermont, FL 34711

P.B.C. Convention Center - Loading Dock Doors Replacement Project
Results
Less than $550,000 est. value
West Palm Beach, FL 33401

SVC-OHDOORS/2021/2 - Repairs and Maintenance to Overhead Doors, Gates and Automatic Door Equipment
Term Contract
Post-Bid
Punta Gorda, FL 33950

Z--Re-Issue Window Replacement
Results
Orlando, FL 32827

Lake Placid Government Center Interior Shutters
Post-Bid
Lake Placid, FL 33852

TGK Security Storefornt Door Replacement
Results
Less than $400,000 est. value
FL

Bipart Sliding Automatic Doors
Post-Bid
Panama City, FL 32409

Hardening and Retrofitting of the City Hall
Results
Less than $340,000 est. value
Tavares, FL

Sports Complex Pool Door Replacement
Post-Bid
Okeechobee, FL 34972

Public Safety Building Ballistic Glass Replacement Project
Results
Sunrise, FL 33351

MC Jail Door Replacement
Post-Bid
Ocala, FL 34475

Last Updated 11/17/2020 11:00 AM
Project Title

Installation of Automatic Door Openers and Push Buttons to Enter/Exit at NAWCTSD Complex

Physical Address View project details and contacts
City, State (County) Orlando, FL 32826   (Orange County)
Category(s) Single Trades
Sub-Category(s) Windows/Doors
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $25,000 to $100,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Furnish and install, fully finished and ready for use six (6) automatic door openers with two (2) pushbuttons each at the center male and female restrooms on each of the three floors of the DeFlorez building. These door openers must have a receptacle installed close to the unit for power. The push buttons must be hardwired to the openers and must not require batteries. The location of the push buttons shall be in accordance with the ADA Standards 404.3.5 Section 308 Reach Ranges, unobstructed forward and side reach shall be 48” maximum and 15” minimum in height. Clean up and protect finishes that are to remain. All work to be coordinated with the government (NSA Orlando, NAVFAC and NAWCTSD). All work shall be installed in accordance all Unified Facility Criteria (e.g. National Electric Code (NEC), Life Safety Code, etc.). Several requirements for this project are as follows: All applicable federal, state, and local codes shall be followed including but not limited to Unified Facility Criteria found at https://www.wbdg.org/ffc/dod/unified-facilities-criteria-ufc Electrical modifications (Changes to existing circuits and locations) Ensuring all electrical work meets NEC requirements Ensuring that all work is tested to be complete and useable Ensuring dust and noise levels are kept to a minimum with daily cleanup.

Details

Division 08 - Openings, Doors and Frames.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents