Similar Projects
Last Updated | 03/24/2021 01:42 PM |
Project Title | Bridge Replacements and Related Work (Including Signals and Wall Structures) Along A Section of Route 24 at Interchange 12, BR No T-01-046 (Steel) Over Route 140 and BR Nos T-01-045 and T-01-047 |
Physical Address | View project details and contacts |
City, State (County) | Taunton, MA 02718 (Bristol County) |
Category(s) | Heavy and Highway |
Sub-Category(s) | Bridge |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $135,152,956 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Bridge Replacements and Related Work (Including Signals & Wall Structures) along a Section of Route 24 at Interchange 12, Br. No. T-01-046 (Steel) over Route 140 and Br. Nos. T-01-045 & T-01-047 (Steel) over Railroad. "1.000","Ls","Schedule Of Operations - Fixed Price $300000","100." "35.000","a","Clearing And Grubbing","101." "120.000","Hr","Control Of Invasive Plants Existing On Site","102.3" "40.000","Hr","Invasive Plant Management Strategy","102.33" "10.000","Ea","Tree Protection – Armoring & Pruning","102.511" "100.000","Ft","Tree And Plant Protection Fence","102.521" "1.000","Ls","Demolition Of Superstructure Of Bridge No. t-01-046","114.1" "1.000","Ls","Demolition Of Bridge No. t-01-045","115.1" "1.000","Ls","Demolition Of Bridge No. t-01-047","115.3" "100400.000","Cy","Unclassified Excavation","120.1" "5720.000","Cy","Topsoil Excavated And Stacked","125." "1970.000","Cy","Reinforced Concrete Excavation","127.1" "68670.000","Cy","Bridge Excavation","140." "8100.000","Cy","Class a Trench Excavation","141." "510.000","Cy","Test Pit For Exploration","141.1" "3630.000","Cy","Class b Trench Excavation","142." "30.000","Cy","Channel Excavation","143." "3660.000","Cy","Class b Rock Excavation","144." "13.000","Ea","Drainage Structure Abandoned","145." "186.000","Ea","Drainage Structure Removed","146." "750.000","Ft","Track Drainage System Removed","146.1" "62100.000","Cy","Special Borrow","150.1" "5520.000","Cy","Lightweight Fill","150.2" "52210.000","Cy","Gravel Borrow","151." "2400.000","Cy","Gravel Borrow For Bridge Foundation","151.1" "55600.000","Cy","Gravel Borrow For Backfilling Structures And Pipes","151.2" "31.000","Cy","Controlled Density Fill - Non-Excavatable","153.1" "5300.000","Ton","Crushed Stone","156." "4670.000","Ton","Crushed Stone For Bridge Foundations","156.1" "109900.000","Sy","Fine Grading And Compacting - Subgrade Area","170." "1.000","Ls","Environmental Health And Safety Program","180.01" "280.000","Hr","Personal Protection Level c Upgrade","180.02" "280.000","Hr","Licensed Site Professional Services","180.03" "11310.000","Ton","Disposal Of Unregulated Soil","181.11" "15100.000","Ton","Disposal Of Regulated Soil - In-State Facility","181.12" "5700.000","Ton","Disposal Of Regulated Soil - Out-Of-State Facility","181.13" "5700.000","Ton","Disposal Of Hazardous Waste","181.14" "1.000","Ls","Inspection And Testing For Asbestos","182.1" "630.000","Ft","Removal Of Asbestos","182.2" "8.000","Ton","Disposal Of Treated Wood Products","184.1" "477.000","Ea","Catch Basin","201." "7.000","Ea","Special Catch Basin - Ballast Inlet","201.31" "1.000","Ea","Special Catch Basin - Underdrain Portal","201.32" "229.000","Ea","Manhole","202." "6.000","Ea","Manhole (9 To 14 Foot Depth)","202.2" "16.000","Ea","Manhole (5 Ft Diameter)","202.5" "10.000","Ea","Manhole (6 Ft Diameter)","202.6" "5.000","Ea","Stormwater Basin Outlet Control Structure","203.12" "2.000","Ea","Gutter Inlet - Special","204.11" "2.000","Ea","Drop Inlet, Type a","206." "3.000","Ea","Drop Inlet, Type Af","206.1" "6.000","Ea","Drop Inlet, Type Df","209.1" "865.000","Ea","Drainage Structure Adjusted","220." "9.000","Ft","Drainage Structure Rebuilt","220.2" "21.000","Ea","Drainage Structure Change In Type","220.3" "6.000","Ea","Drainage Structure Remodeled","220.5" "10.000","Ft","Sanitary Structure Rebuilt","220.6" "12.000","Ea","Sanitary Structure Adjusted","220.7" "41.000","Ea","Frame And Cover","221." "260.000","Ea","Frame And Cover - Secured","221.1" "397.000","Ea","Frame And Grate - Massdot Bar Type","222." "1.000","Ea","Frame And Grate - Massdot Cascade Type","222.1" "11.000","Ea","Frame And Grate - Massdot Drop Inlet","222.2" "182.000","Ea","Frame And Grate (Or Cover) Removed And Discarded","223.2" "31.000","Ea","10 Inch Hood","224.10" "88.000","Ea","12 Inch Hood","224.12" "8.000","Hr","Internal Pipe Inspection By Video Camera","226.32" "670.000","Cy","Removal Of Drainage Structure Sediment","227.3" "3390.000","Ft","Removal Of Drainage Pipe Sediment","227.31" "60.000","Sf","Masonry Plug","227.4" "360.000","Ft","12 Inch Corrugated Metal Pipe 16 Gage","230.112" "40.000","Ft","15 Inch Corrugated Metal Pipe 16 Gage","230.115" "30.000","Ft","18 Inch Corrugated Metal Pipe 16 Gage","230.118" "7.000","Ea","12 Inch Corrugated Metal Pipe End Section","230.712" "1.000","Ea","15 Inch Corrugated Metal Pipe End Section","230.715" "1.000","Ea","18 Inch Corrugated Metal Pipe End Section","230.718" "3470.000","Ft","12 Inch Slotted Drain","230.912" "420.000","Ft","10 Inch Ductile Iron Pipe","238.10" "920.000","Ft","12 Inch Ductile Iron Pipe","238.12" "10920.000","Ft","12 Inch Reinforced Concrete Pipe","241.12" "1310.000","Ft","15 Inch Reinforced Concrete Pipe","241.15" "920.000","Ft","18 Inch Reinforced Concrete Pipe","241.18" "90.000","Ft","24 Inch Reinforced Concrete Pipe","241.24" "15.000","Ft","36 Inch Reinforced Concrete Pipe","241.36" "140.000","Ft","48 Inch Reinforced Concrete Pipe","241.48" "27.000","Ea","12 Inch Reinforced Concrete Pipe Flared End","242.12" "8.000","Ea","15 Inch Reinforced Concrete Pipe Flared End","242.15" "7.000","Ea","18 Inch Reinforced Concrete Pipe Flared End","242.18" "2.000","Ea","24 Inch Reinforced Concrete Pipe Flared End","242.24" "1.000","Ea","30 Inch Reinforced Concrete Pipe Flared End","242.30" "3140.000","Ft","12 Inch Reinforced Concrete Pipe Class Iv","243.12" "360.000","Ft","15 Inch Reinforced Concrete Pipe Class Iv","243.15" "3750.000","Ft","12 Inch Reinforced Concrete Pipe Class v","244.12" "110.000","Ft","15 Inch Reinforced Concrete Pipe Class v","244.15" "210.000","Ft","18 Inch Reinforced Concrete Pipe Class v","244.18" "170.000","Ft","30 Inch Reinforced Concrete Pipe Class v","244.30" "940.000","Sy","Stone For Pipe Ends","258." "50.000","Ton","Crushed Stone For Bleeders","259." "750.000","Ft","18 Inch Pipe Subdrain - Hdpe","265.18" "4180.000","Ft","8 Inch Slot-Perforated Corrugated Plastic Pipe (Subdrain)","269.08" "90.000","Sy","Cement Concrete Paving (Waterway)","281." "540.000","Ft","12 Inch Ductile Iron Water Pipe (Rubber Gasket)","302.12" "120.000","Ft","6 Inch Ductile Iron Water Pipe (Mechanical Joint)","303.06" "3500.000","Lb","Ductile Iron Fittings For Water Pipe","309." "1.000","Ls","Water Service Removed And Discarded","316." "3.000","Ea","6 Inch Gate Box","357.06" "4.000","Ea","12 Inch Gate Box","357.12" "2.000","Ea","Gate Box Adjusted","358." "4.000","Ea","6 Inch Cast Iron Plug","367.06" "1.000","Ea","12 x 6 Inch Tapping Sleeve, Valve And Box","370.4" "2.000","Ea","6 Inch Coupling","371.06" "4.000","Ea","12 Inch Coupling","371.12" "1.000","Ea","Hydrant - Removed And Reset","376.2" "2.000","Ea","Hydrant - Removed And Stacked","376.3" "13900.000","Cy","Dense Graded Crushed Stone For Sub-Base","402." "6600.000","Ft","Pavement Milling Mulch For Shoulders","402.13" "83300.000","Sy","Pavement Standard Milling","415.1" "2100.000","Sy","High Early Strength Cement Concrete Base Course","431." "133500.000","Lb","Calcium Chloride For Roadway Dust Control","440." "600.000","Mgl","Water For Roadway Dust Control","443." "30.000","Ton","Superpave Surface Course – 9.5 (Ssc – 9.5)","450.22" "10100.000","Ton","Superpave Surface Course – 9.5 Polymer (Ssc – 9.5 - p)","450.221" "22700.000","Ton","Superpave Surface Course - 12.5 Polymer (Ssc - 12.5 - p)","450.231" "50.000","Ton","Superpave Intermediate Course - 12.5 (Sic -12.5)","450.31" "9900.000","Ton","Superpave Intermediate Course - 19.0 (Sic - 19.0)","450.32" "23600.000","Ton","Superpave Intermediate Course - 19.0 Polymer (Sic - 19.0 - p)","450.321" "60.000","Ton","Superpave Base Course - 25.0 (Sbc - 25.0)","450.41" "28300.000","Ton","Superpave Base Course - 37.5 (Sbc - 37.5)","450.42" "530.000","Ton","Superpave Bridge Surface Course - 9.5 Polymer (Ssc-b - 9.5 - p)","450.601" "530.000","Ton","Superpave Bridge Protective Course – 12.5polymer (Spc-b - 12.5 - p)","450.711" "3630.000","Ton","Hma For Patching","451." "39000.000","Gal","Asphalt Emulsion For Tack Coat","452." "170700.000","Ft","Hma Joint Sealant","453." "1240.000","Ton","Hot Mix Asphalt Berm, Type a","470." "10100.000","Ton","Asphalt Mixtures For Temporary Work","472." "47100.000","Ft","Milled Rumble Strip","477." "36900.000","Ft","Sawcutting Asphalt Pavement For Box Widening","482.5" "70.000","Ft","Granite Curb Type Va5 - Straight","505." "130.000","Ft","Granite Curb Type Vb - Straight","506." "80.000","Ft","Granite Curb Type Vb - Curved","506.1" "60.000","Ft","Granite Transition Curb For Wheelchair Ramps - Straight","509." "230.000","Ea","Granite Curb To Sloped Edging Transition","509.2" "5200.000","Ft","Granite Edging Type Sb - Straight","511.1" "220.000","Ft","Granite Edging Type Sb (Radius 10 Feet Or Less)","512.1" "87.000","Ea","Granite Curb Inlet - Straight","514." "28.000","Ea","Granite Curb Inlet - Curved","515." "120.000","Ft","Granite Curb - t100","525." "110.000","Ft","Curb Removed And Reset","580." "17900.000","Ft","Edging Removed And Reset","583." "240.000","Ft","Curb Removed And Discarded","594." "6000.000","Ft","Edging Removed And Discarded","597." "6200.000","Ft","Guardrail, Tl-2 (Single Faced)","620.12" "13150.000","Ft","Guardrail, Tl-3 (Single Faced)","620.13" "160.000","Ft","Guardrail - Curved, Tl-2 (Single Faced)","620.32" "270.000","Ft","Guardrail - Curved, Tl-3 (Single Faced)","620.33" "680.000","Ft","Guardrail, Tl-3 (Double Faced)","621.13" "18.000","Ea","Trailing Anchorage","627.1" "1.000","Ea","Guardrail End Treatment, Tl-3 (Double Faced)","627.73" "4.000","Ea","Guardrail Tangent End Treatment, Tl-2","627.82" "17.000","Ea","Guardrail Tangent End Treatment, Tl-3","627.83" "2.000","Ea","Transition To Nchrp 350 Guardrail","628.21" "3.000","Ea","Transition To Rigid Barrier (Single Faced)","628.22" "4.000","Ea","Transition To Rigid Barrier (Double Faced)","628.23" "15.000","Ea","Transition To Bridge Rail","628.24" "4.000","Ea","Transition To Thrie Beam","628.25" "3.000","Ea","Impact Attenuator For Median, Capable Of Redirection","628.34" "3210.000","Ft","Precast Concrete Barrier - Single Faced","629.1" "13800.000","Ft","Precast Concrete Median Barrier - Double Faced","629.2" "2200.000","Ft","Precast Concrete Median Barrier - Double Faced - Removed And Reset","629.21" "150.000","Ft","Cast-In-Place Concrete Median Barrier - Double Faced","629.4" "36650.000","Ft","Highway Guard Removed And Discarded","630.2" "5350.000","Ft","72 Inch Chain Link Fence (Spring Tension Wire) (Line Post Option)","644.072" "8.000","Ea","72 Inch Chain Link Fence End Post","652.072" "4.000","Ea","72 Inch Chain Link Fence Corner Or Intermediate Brace Post","653.072" "1000.000","Ft","Chain Link Fence Removed And Reset","666." "370.000","Ft","Chain Link Fence Removed And Discard","666.1" "320.000","Cy","Stone Masonry Wall In Cement Mortar","685." "1060.000","Ea","Silt Sack","697.1" "17130.000","Sy","Geotextile Fabric For Separation","698.3" "570.000","Sy","Geotextile Fabric For Permanent Erosion Control","698.4" "4300.000","Sy","Cement Concrete Sidewalk","701." "40.000","Sy","Cement Concrete Wheelchair Ramp","701.2" "30.000","Ton","Hot Mix Asphalt Sidewalk Or Driveway","702." "60.000","Sy","Stamped Concrete Truck Apron","703.5" "7.000","Ea","Bound - Lettered Granite","710.3" "4.000","Ea","Bound Removed And Reset","711." "77.000","Mo","Engineers Field Office And Equipment (Type a)","740." "1.000","Ls","Mobilization","748." "7330.000","Cy","Loam Borrow","751." "8580.000","Sy","Compost Topdressing","751.72" "5720.000","Cy","Topsoil Rehandled And Spread","752." "1.000","Ls","Inland Wetland Mitigation Area","755.35" "2450.000","Sy","Wetland Restoration","755.45" "1110.000","Ft","Streambed Restoration","755.50" "200.000","Hr","Wetland Specialist","755.75" "1.000","Ls","Wetland Monitoring Reports","755.76" "1.000","Ls","Npdes Stormwater Pollution Prevention Plan","756." "98800.000","Sy","Seeding","765." "16000.000","Sy","Seeding - Infiltration Basin / Swale","765.456" "1360.000","Sy","Seeding - Wet Basin Bottom / Swale Mix","765.457" "10380.000","Sy","Seeding Wildflower Mix","765.8" "17300.000","Ft","Sediment Control Barrier","767.121" "32100.000","Ft","Pavement Milling Mulch Under Guard Rail","769." "70.000","Ft","Ductbank - Telephone - 8x4inch Encased","800.01" "2290.000","Ft","Ductbank - Telephone - 6x4inch Encased","800.02" "80.000","Ft","Ductbank - Telephone- 2x4inch Encased","800.03" "2360.000","Ft","Ductbank - Electrical - 10x5inch Encased","800.04" "60.000","Ft","Ductbank - Electrical 4x5inch Encased","800.05" "290.000","Ft","Ductbank - Electrical - 2x5inch Encased","800.06" "120.000","Ft","Ductbank - Catv - 1x4inch","800.07" "350.000","Ft","2 Inch Electrical Conduit Type Nm - Plastic (Ul)","804.2" "21500.000","Ft","3 Inch Electrical Conduit Type Nm - Plastic -(Ul)","804.3" "410.000","Ft","4 Inch Electrical Conduit Type Nm - Plastic -(Ul)","804.4" "40.000","Ft","5 Inch Electrical Conduit Type Rm - Galvanized Steel","806.5" "600.000","Ft","1 Inch Electrical Conduit Type Rm Steel (Plastic Coated)","808.1" "6.000","Ea","Electric Manhole","811.01" "11.000","Ea","Electric Manhole Removed","811.011" "5.000","Ea","Telephone Manhole","811.02" "3.000","Ea","Telephone Manhole Removed","811.021" "53.000","Ea","Electric Handhole - Sd2.022","811.22" "21.000","Ea","Electric Handhole - Sd2.023","811.23" "1.000","Ea","Electric Handhole - Sd2.024","811.24" "38.000","Ea","Pull Box 12 x 12 Inches - Sd2.031","811.31" "8.000","Ea","Electric Handhole Removed And Discarded","811.391" "3.000","Ea","Junction Box 18 x 12 x 8 Inches","811.71" "12.000","Ea","Barrier Junction Box 24 x 12 x 8 Inches","811.841" "9.000","Ea","Light Standard Foundation Sd3.013","812.13" "17.000","Ea","Light Standard Foundation Sd3.014","812.14" "5.000","Ea","Light Standard Foundation, 100 Foot High Mast","812.162" "1900.000","Ft","Wire Type 8 No. 10 Direct Burial","813.40" "47500.000","Ft","Wire Type 8 No. 6 Direct Burial","813.42" "800.000","Ft","Wire Type 10 No. 10 Grounding And Bonding","813.521" "15500.000","Ft","Wire Type 10 No. 6 Grounding And Bonding","813.522" "1.000","Ls","Communications Cable System","813.792" "1.000","Ls","Highway Lighting Service Connection (Underground)","813.811" "1.000","Ls","Adaptive Traffic Signal System","814." "1.000","Ls","Traffic Control Signal Location No. 2","815.2" "1.000","Ls","Traffic Signal Reconstruction Location No. 1","816.01" "1.000","Ls","Traffic Signal Reconstruction Location No. 3","816.03" "1.000","Ls","Traffic Signal Reconstruction Location No. 4","816.04" "1.000","Ls","Traffic Signal Reconstruction Location No. 5","816.05" "1.000","Ls","Temporary Traffic Signal Location No. 1","816.811" "1.000","Ls","Temporary Traffic Signal Location No. 2","816.812" "1.000","Ls","Remove And Relocate Existing Camera Site","817.545" "1.000","Ls","Protect Existing Go Time Reader Site","819.745" "6.000","Ea","Highway Lighting Pole - 50-Feet (Anchor Base) 6 Foot Bracket","821.111" "6.000","Ea","Highway Lighting Pole - 40-Feet (Anchor Base) 8 Foot Bracket","821.121" "17.000","Ea","Highway Lighting Pole - 50-Feet (Anchor Base) 8 Foot Bracket","821.122" "3.000","Ea","Highway Lighting Pole - 40-Feet (Anchor Base) Twin 8 Foot Bracket","821.221" "5.000","Ea","High Mast Tower (100 Foot Mounting Height)","822.88" "23.000","Ea","Highway Lighting Luminaire 20000 Lumen Led","823.111" "12.000","Ea","Highway Lighting Luminaire 30000 Lumen Led","823.112" "34.000","Ea","Area Lighting Luminaire 45k Lumen Led (Highmast)","823.191" "9.000","Ea","Underpass Lighting Luminaire","823.361" "1.000","Ls","Highway Lighting Load Center","823.60" "330.000","Sf","Overhead Guide Sign Removed And Reset","828.01" "10.000","Ea","Overhead Guide Sign And Support Removed And Discarded","828.06" "3120.000","Sf","Overhead Guide Sign - Aluminum Panel (Type b)","828.1" "1220.000","Sf","Roadside Guide Sign (g) - Aluminum Panel (Type b)","829." "150.000","Sf","Roadside Guide Sign (Ma-d1-Xx) - Aluminum Panel (Type b)","829.01" "260.000","Sf","Roadside Guide Sign (g/e5) - Remove And Reset","829.02" "20.000","Ea","Roadside Guide Sign And Support (g) Removed And Discarded","829.06" "6.000","Ea","Roadside Guide Sign And Support (d6/d8) Removed And Discarded","829.07" "5.000","Ea","Roadside Guide Sign (g/e5) And Support Removed And Reset","829.08" "300.000","Sf","Roadside Guide Sign (e5) - Aluminum Panel (Type b)","829.1" "1690.000","Sf","Warning-Regulatory And Route Marker - Aluminum Panel (Type a)","832." "110.000","Sf","Reflectorized Sign Overlay","832.12" "1.000","Ls","Supports For Overhead Guide Sign (Od-1) Steel","840.101" "1.000","Ls","Supports For Overhead Guide Sign (Od-2) Steel","840.102" "1.000","Ls","Supports For Overhead Guide Sign (Od-4) Steel","840.104" "1.000","Ls","Supports For Overhead Guide Sign (Od-5) Steel","840.105" "1.000","Ls","Supports For Overhead Guide Sign (Od-7) Steel","840.107" "1.000","Ls","Supports For Overhead Guide Sign (Od-8) Steel","840.108" "1.000","Ls","Supports For Overhead Guide Sign (Od-9) Steel","840.109" "1.000","Ls","Supports For Overhead Guide Sign (Od-10) Steel","840.110" "1.000","Ls","Supports For Overhead Guide Sign (Od-11) Steel","840.111" "1.000","Ls","Supports For Relocated Overhead Guide Sign (Ex-Od-2) Steel","840.302" "1.000","Ls","Overhead Guide Sign Support Removed And Reset (Ex-Od-1)","840.401" "1.000","Ls","Overhead Guide Sign Support Removed And Reset (Ex-Od-3)","840.403" "1.000","Ls","Overhead Guide Sign Support Removed And Reset (Ex-Od-4)","840.404" "1.000","Ea","Supports For Guide Sign (d6 w/ d8-5 Inch Tubular Post) Steel","841.1" "1.000","Ea","Supports For Guide Sign (Ma-d1-Xx) Steel","841.81" "1.000","Ls","Supports For Guide Sign (g1) Steel","844.101" "1.000","Ls","Supports For Guide Sign (g2) Steel","844.102" "1.000","Ls","Supports For Guide Sign (g3) Steel","844.103" "1.000","Ls","Supports For Guide Sign (g4) Steel","844.104" "1.000","Ls","Supports For Guide Sign (g5) Steel","844.105" "1.000","Ls","Supports For Guide Sign (g6) Steel","844.106" "1.000","Ls","Supports For Guide Sign (g7) Steel","844.107" "1.000","Ls","Supports For Guide Sign (g10) Steell","844.110" "1.000","Ls","Supports For Guide Sign (Ma-d9-20a(1)) Steel","844.111" "1.000","Ls","Support For Guide Sign (Ma-d9-20a(2)) Steel","844.112" "1.000","Ls","Supports For Relocated Guide Sign (Ex-g-3) Steel","844.303" "6.000","Ea","Support For Guide Sign (e5-1a) Steel","846.1" "2.000","Ea","Sign Sup (n/Guide)+Rte Mkr w/1brkway s-Beam Post Assembly - Steel","846.2" "100.000","Ea","Sign Sup (n/Guide)+Rte Mkr w/1 Brkway Post Assembly - Steel","847.1" "100.000","Ea","Sign Sup (n/Guide)+Rte Mkr w/2 Brkway Post Assemblies-Steel","848.1" "5600.000","Hr","Roadway Flagger","850.41" "2000.000","Day","Traffic Cones For Traffic Management","851.1" "6800.000","Sf","Safety Signing For Traffic Management","852." "28.000","Ea","Portable Breakaway Barricade Type Iii","853.1" "84540.000","Ft","Temporary Barrier Removed And Reset","853.21" "38500.000","Ft","Temporary Barrier - Limited Deflection (Tl-3)","853.33" "7900.000","Day","Truck Mounted Attenuator","853.403" "20.000","Ea","Temporary Impact Attenuator For Shldr, Incapable Of Redirection","853.41" "40.000","Ea","Temporary Impact Attenuator For Shoulder, Incapable Of Redirection, Removed And Reset","853.411" "1.000","Ea","Temporary Impact Attenuator Removed And Reset","853.501" "2.000","Ea","Temporary Impact Attenuator Unidirectional, Non-Redirective (Tl-3)","853.53" "880.000","Day","Temporary Illumination For Work Zone","853.8" "1590.000","Ft","Temporary Roadway Delineator","853.9" "1020.000","Sf","Temporary Pavement Markings - Arrows & Legends (Painted)","854.01" "473100.000","Ft","Temporary Paving Markings - 6 Inch (Painted)","854.016" "80100.000","Ft","Temporary Paving Markings - 6 Inch (Tape)","854.036" "112900.000","Sf","Pavement Marking Removal","854.1" "11000.000","Ft","Temporary Pavement Markings - 12 In. (Painted)","854.112" "1170.000","Ea","Raised Pavement Marker Removal","854.5" "9000.000","Day","Temporary Portable Rumble Strip","854.6" "12500.000","Day","Arrow Board","856." "11100.000","Day","Portable Changeable Message Sign","856.12" "1.000","Ls","Real Time Traffic Management For Work Zones","856.3" "312400.000","Day","Reflectorized Drum","859." "33200.000","Day","Reflectorized Drums With Sequential Flashing Warning Lights","859.1" "12500.000","Ft","6 Inch Reflectorized White Line (Painted)","860.106" "3200.000","Ft","12 Inch Reflectorized White Line (Painted)","860.112" "10000.000","Ft","6 Inch Reflectorized Yellow Line (Painted)","861.106" "1890.000","Sf","Pavement Arrows And Legends Reflectorized White (Thermoplastic)","864.04" "690.000","Ea","Slotted Pavement Marker One-Way White","864.31" "440.000","Ea","Slotted Pavement Marker Two-Way White/Red","864.33" "220.000","Ea","Slotted Pavement Marker Two-Way Yellow/Red","864.34" "20.000","Ea","Slotted Pavement Marker Two-Way Yellow/Yellow","864.35" "15200.000","Ft","6 Inch Reflectorized White Line (Thermoplastic)","866.106" "13500.000","Ft","12 Inch Reflectorized White Line (Thermoplastic)","866.112" "37400.000","Ft","6 Inch Reflectorized White Line (Polyurea) (Recessed)","866.206" "6300.000","Ft","12 Inch Reflectorized White Line (Polyurea) (Recessed)","866.212" "12000.000","Ft","6 Inch Reflectorized Yellow Line (Thermoplastic)","867.106" "320.000","Ft","12 Inch Reflectorized Yellow Line (Thermoplastic)","867.112" "26500.000","Ft","6 Inch Reflectorized Yellow Line (Polyurea) (Recessed)","867.206" "40.000","Ft","12 Inch Reflectorized Yellow Line (Polyurea) (Recessed)","867.212" "26.000","Ea","Traffic Sign Removed And Reset","874.2" "230.000","Ea","Traffic Sign Removed And Discarded","874.41" "60.000","Cy","4000 Psi, 1.5 Inch, 565 Cement Concrete","901." "60.000","Cy","3000 Psi, 1.5 Inch, 470 Cement Concrete","903." "190.000","Cf","Superstructure Concrete Patching - Surface Patch","909.41" "370.000","Cf","Superstructure Concrete Patch - Deep Patch","909.42" "60.000","Cf","Substructure Concrete Patching - Deep Patch","909.43" "760.000","Lb","Steel Reinforcement For Structures - Epoxy Coated","910.1" "1.000","Ls","Temporary Earth Support Bridge No. t-01-045","950.111" "1.000","Ls","Temporary Earth Support Bridge No. t-01-046","950.112" "1.000","Ls","Temporary Earth Support Bridge No. t-01-047","950.113" "1.000","Ls","Temporary Support Of Excavation - Bridge No t-01-054","950.5" "45.000","Sy","Excavation Support System","953.3" "1.000","Ea","Temporary Waterway Diversion Structure","954.1" "185.000","Ton","Dumped Riprap","983." "40.000","Ton","Riprap","983.1" "120.000","Sy","Slope Paving Removed And Reset","985.01" "4400.000","Ton","Modified Rockfill","986." "160.000","Sy","Channel Paving","988." "1330.000","Sf","Sediment Forebay Paving","988.01" "40.000","Cy","Repairs To Concrete","989.3" "1.000","Ls","Control Of Water - Structure No. t-01-045","991.1" "1.000","Ls","Control Of Water - Structure No. t-01-046","991.2" "1.000","Ls","Control Of Water - Structure No. t-01-047","991.3" "1.000","Ls","Control Of Water - Structure No. t-01-054","991.4" "1.000","Ls","Alteration To Bridge Structure No. t-01-054","992.1" "1.000","Ls","Temporary Superstructure Support Bridge No. t-01-045","992.331" "1.000","Ls","Temporary Superstructure At Median Bridge No t-01-046","992.332" "1.000","Ls","Temporary Superstructure Support Bridge No t-01-047","992.333" "1.000","Ls","Temporary Protective Shielding Bridge No. t-01-045","994.01" "1.000","Ls","Temporary Protective Sheilding Bridge No t-01-046","994.02" "1.000","Ls","Temporary Protective Sheilding Bridge No t-01-047","994.03" "1.000","Ls","Bridge Structure, Bridge No. t-01-045","995.01" "1.000","Ls","Bridge Structure, Bridge No. t-01-046","995.02" "1.000","Ls","Bridge Structure, Bridge No. t-01-047","995.03" "1.000","Ls","Wall Structure, Wall No. 01","996.001" "1.000","Ls","Wall Structure, Wall No. 02","996.002" "1.000","Ls","Wall Structure, Wall No. 03","996.003" "1.000","Ls","Wall Structure, Wall No. 04","996.004" "1.000","Ls","Wall Structure, Wall No. 05","996.005" "1.000","Ls","Wall Structure, Wall No. 06","996.006" "1.000","Ls","Wall Structure, Wall No. 09","996.009" "1.000","Ls","Wall Structure, Wall No. 10","996.010" "1.000","Ls","Wall Structure, Wall No. 11","996.011" "1.000","Ls","Wall Structure, Wall No. 12","996.012" "1.000","Ls","Permanent Earth Support, Bridge No. t-01-047","996.033" "1.000","Ls","Special Headwall Structure No. 1","997.1" "1.000","Ls","Special Headwall Structure No. 2","997.2" |
||||||||||||||||||||
Details |
|
||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |