Similar Projects
Apex Warehouse - Drainage Rehabilitation
Infrastructure
Bidding
Apex, NC 27502

Raleigh Green Stormwater Infrastructure Retrofits
Post-Bid
Less than $600,000 est. value
Raleigh, NC 27602

Bay Leaf Station 3 - Site Drainage Improvements
Post-Bid
Raleigh, NC 27612

Dorothea Drive Drainage Improvements (Formal)
Results
Raleigh, NC

Stormwater Drainage Assistance Program - Spring Drive Drainage Improvements
Results
Raleigh, NC

Stormwater Drainage Assistance - Chapel Hill Road Drainage Improvements
Post-Bid
Less than $317,000 est. value
Raleigh, NC 27607

Streambank Repairs
Results
Raleigh, NC 27604

Pond Breach and French Drain Package of the E-51 Woods Creek Elementary School Project
Post-Bid
Cary, NC

Kelly Point Ct Drainage Improvements
Results
Less than $100,000 est. value
Apex, NC 27502

Streambank Repairs (Formal)
Post-Bid
Raleigh, NC

Stormwater Drainage Assistance Program
Results
Less than $120,888 est. value
Raleigh, NC 27602

Stormwater Drainage Assistance Program - Bundle Project 3
Post-Bid
Less than $381,000 est. value
Raleigh, NC 27612

Stream Bank Repairs
Results
Raleigh, NC 27601

Stormwater Drainage Assistance Program - 904 Wakestone Court
Post-Bid
Raleigh, NC

Corrugated Metal Pipe for Stone Creek/Bear Garden Project
Results
Raleigh, NC 27699

Last Updated 08/25/2021 01:06 AM
Project Title

Headwall

Physical Address View project details and contacts
City, State (County) Knightdale, NC 27545   (Wake County)
Category(s) Heavy and Highway
Sub-Category(s) Shoreline/Erosion/Drainage
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

1 1 Each 12’ 11” x 7’ 6” x 74’ x .200 thickness aluminum structural pipe arch fully welded to the inlet and outlet headwalls. See attached drawings 2 1 Each 27’ x 10’ 6” headwall (inlet end). Fully welded structural aluminum plate. Headwalls shall be designed for surcharge. Backfill shall be in accordance of the 2018 NCDOT standard specifications and roadway standard drawings. Backfill shall be select backfill material class III or class II Type I or class IV (ABC) #57 washed stone shall not be utilized as back fill. 3 1 Each 27’ x 10’ 6” headwall (outlet end). Fully welded structural aluminum plate. Headwalls shall be designed for surcharge. Backfill shall be in accordance of the 2018 NCDOT standard specifications and roadway standard drawings. Backfill shall be select backfill material class III or class II Type I or class IV (ABC) #57 washed stone shall not be utilized as back fill. 4 1 Each One roll of geogrid soil stabilization material equivalent to Tensar 160, 13’ x 246’ roll. 5 1 Each Manufacturer shall provide on-site technical assistance during assembly, installation, and backfilling operations of structure. 6 1 Each Onsite contract personnel to fully assemble structure on site

Details

Division 31 - Earthwork, Erosion and Sedimentation Controls.
Division 33 - Utilities, Storm Drainage Utilities, Ponds and Reservoirs.
Division 35 - Waterway and Marine Construction, Shoreline Protection, Waterway Construction and Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents