Similar Projects
Uninterruptible Power Supply (UPS)
Bidding
Dallas, TX 75214

Term Contract for Underground Line Locating Services
Term Contract
Bidding
$250,000 est. value
Garland, TX

Electrical Maintenance and Repair Services for the Dallas District
Post-Bid
Mesquite, TX 75150

SE Regional Generator Maintenance
Term Contract
Post-Bid
Garland, TX 75043

Performance Hall Equipment Upgrade
Results
$341,960 est. value
Mesquite, TX 75149

Studio Production Lights Upgrade
Results
$77,201 est. value
Dallas, TX

Irving Blvd/Sh356 (Pioneer to Sowers) Streetlight Project
Bidding
Irving, TX

Video Projector
Post-Bid
Irving, TX 75060

Addison Airport Toll Tunnel Sump Pump Wiring Systems
Results
$1,000,000 to $2,000,000 est. value
Addison, TX 75001

Steel Monopole Structures for King Mountain to Queen Bess 345 KV Transmission Line
Bidding
Garland, TX

Ballroom Stage Lighting
Post-Bid
Richardson, TX 75080

Emergency Generator Repair and Maintenance
Term Contract
Results
$673,610 est. value
Dallas, TX 75201

Instrumentation Services for Water Utilities
Post-Bid
Irving, TX 75060

Generator/ATS Inspections
Results
Dallas, TX 75212

Tree Light and Illumination for Rawhide Park Water Surface
Post-Bid
Farmers Branch, TX 75234

Last Updated 08/18/2020 08:52 AM
Project Title

Transmission Under-Build (GP&L Distribution)

Physical Address View project details and contacts
City, State (County) Garland, TX 75040   (Dallas County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Scope of Work: SR 494812 - AP-LK Replace 30 – 45’ wood poles with 45’ steel poles Replace 7 – 50’ wood poles with 50’ steel poles Replace 12 – 45’ wood poles Re-conductor approximately 1500’ of #477 ACSR, 4/0 ACSR three phase primary Replace 1- 30’ wood pole with overhead guy Transfer 4 - #1000 kcm three phase feeder risers Transfer 5 - #2/0 single phase risers All steel poles will be install with a concrete collar. Specification will be provided. SR 507045 – Re-conductor Section of JU-3 Re-conductor approx. 7506’ of 3-#477 ACSR primary and 2489’ of 1-#4/0 ACSR neutral Replace 900 amp air switch One 40’ wood pole SR 501940 – Re-conductor Section of CD-1/CR-6 Re-conductor approx. 17,626 of 3-#477 ACSR primary and 5862’ of 1-#4/0 neutral Replace 9-45’ wood poles Install 900 amp air switch SR 507054 – CR-3: Add Partial Double Circuit & Transfer Load Install approx. 6782’ of 3-477 ACSR primary (above existing circuit) Replace wood poles with 14-50’ and 2-55’ steel poles Install 2 vertical 900 amp air switches Transfer pole risers SR 507067 – Re-conductor Part of MQ-3 Re-conductor approx. 6576’ of 3-477 ACSR primary and 2192’ of #4/0 ACSR neutral Replace 4-45’wood poles with steel. Install 900 amp air switch.

Details

Division 26 - Electrical, Low-Voltage Electrical Transmission.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents