Project Title | Repair Sustain HVAC Rm 169 & 264 Bldg. 1607 |
Physical Address | View project details and contacts |
City, State (County) | Lincoln, MA (Middlesex County) |
Category(s) | Single Trades |
Sub-Category(s) | HVAC |
Contracting Method | Design-Build. Competitive Bids. |
Project Status | Accepting Letters of Interest |
Bids Due | View project details and contacts |
Estimated Value | $1,000,000 to $5,000,000 |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The general scope of the prospective project shall be accomplished using a Design Build (DB) delivery method. The intent is to transform the existing Data Centers to reliable state of the art Data Centers with fully redundant HVAC system with specific self-contained automated rack temperature, humidity, and power controls. Work consists of multidiscipline Design Build effort to upgrade, reconfigure, resize, existing Data centers HVAC system for 169, 264 and any affected spaces and redundant InRow rack cooling for existing APC racks in rooms 169 and 246. The Design Build effort shall provide a new design and layout to replace the existing HVAC systems (components, devices, utilities, chilled water, humidity equipment, controls, mechanical piping, plumbing, refrigeration system, electrical, and associated instrumentation, lighting, electrical, communication, structural supports, and infrastructure) for rooms 169, 264 and supporting and adjacent spaces with new redundant InRow rack Cooling with self-contained controls and new space HVAC system in its entirety for rooms 169, 264 and supporting adjacent areas, located in Building 1607. This effort includes Title 1A and verification of existing condition assessment report, Title 1B design services and construction, furnishing all labor, materials, equipment, tools, travel, supervision, construction management, Preliminary, interim, and final phasing plan, providing temporary HVAC system, testing and balancing, performance verification, independent commissioning, Provide refrigerant leak detection system, purging, and reclamation system and alarms. Johnson Controls Metasys DDC system to integrate the Air Handling units (AHUs), and roof top fans (RFs), CAVs, VAVs, space temperature, VFDs, pumps, space humidity controls and misc. components that are not part of the InRow rack cooling system to Building |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |