Similar Projects
Electrical Services
Design
$2,500 to $20,000,000 est. value
Sullivan, IN

Mechanical & Electrical System Services
Post-Bid
Crane, IN 47522

VPA Security System Upgrades
Post-Bid
South Bend, IN 46601

Valparaiso TOD Electrical
Results
Valparaiso, IN 46383

Bl044 McCalla- Modification Of Incoming Electrical Service
Results
Bloomington, IN 47408

Emergency Lighting and Communication Equipment Installation
Term Contract
Post-Bid
Indianapolis, IN 46204

WTP Switchgear Improvements
Results
Evansville, IN 47708

Preventative Maintenance for the Emergency Generators
Term Contract
Post-Bid
Less than $150,000 est. value
Indianapolis, IN 46201

Hammond Central High School - Technology and Black Box AV Systems
Renovation
Results
Hammond, IN 46320

FMS 6 Terre Haute FMS 8 Stout Field OV Energy Conservation
Post-Bid
Less than $150,000 est. value
Evansville, IN 47715

Deer Hollow Lift Station Improvements
Results
Fort Wayne, IN 46802

Portable Light Tower
Post-Bid
Indianapolis, IN 46077

North Main Plant Generator Upgrade
Results
Elkhart, IN 46516

Indiana Convention Center Exhibit Hall Lighting Upgrade
Renovation
Post-Bid
Indianapolis, IN 46225

Site Finishing Electrical/Low-Voltage Package
Results
$3,500,000 to $4,000,000 est. value
Indianapolis, IN 46203

Reported 03/23/2021 12:00 AM
Project Title

61--Ups Battery

Physical Address View project details and contacts
City, State (County) Crane, IN   (Martin County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

We require a pre-assembled, 60kW UPS system. 60kVA/60kW, Parallel System 3 Phase 208/120V Input/Output Harmonic Distortion (<5% THD) 30 minutes of Runtime at 60kW Input must be hard wired into 5-wire (3PH, + N + G), 208 volts, 3-phase, 60Hz, 150 amp panel. Output requires 54kW load, 5-wire (3PH, + N + G), 208 volts, 3-phase, 150 amps with a minimum of 7500 Watt for 30-minute run time. Total number of batteries should support 30 minute run time at 208 volts, 3-phase, 150 amps with a minimum of 7500 Watt. Batteries should be such that can be easily exchanged without interrupting power supply. The unit should include an internal three breaker maintenance bypass to prevent power interruption during maintenance. Batteries should be maintenance-free lead acid. Start up service is required. Unit should be rack or cabinet mounted.

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents