Similar Projects
Plumbing Repair Services
Alteration
Post-Bid
$200,000 est. value
Boston, MA

Installation of Water Bottle Refill Stations at Various Schools - Package 4 - GC Bid
Alteration
Post-Bid
$544,000 est. value
Boston, MA

Repair Sprinkler System In Building 8 at USCG Base Boston
Term Contract
Results
$25,000 est. value
Boston, MA 02109

Neighborhood House Charter School High School Bathroom Renovation - SUB Bid
Alteration
Results
$248,400 est. value
Boston, MA 02122

Two 42IN RS Gate Valve W Spur and 6IN Bypass
Term Contract
Post-Bid
Boston, MA 02203

Fire Pump Replacement at China Trade Center - Filed Sub Bids
Renovation
Results
$62,000 CJ est. value
Boston, MA 02116

High School Bathroom Plumbing Renovation
Renovation
Post-Bid
$20,000 CJ est. value
Boston, MA 02124

Structural Repairs and Sanitary Line Replacement at General Warren Development - Sub
Infrastructure
Results
$154,752 CJ est. value
Boston, MA 02129

On-Call Plastering for Various Boston Public Schools Group 3
Term Contract
Post-Bid
Boston, MA 02203

Upgrade Pipe/Valves at PRV Station & In Water Tank Valve Vault - GC
Renovation, Infrastructure
Results
$1,627,677 CJ est. value
Winthrop, MA 02152

CPS - Plumbing Services
Term Contract
Post-Bid
Chelsea, MA 02150

Furnish and Deliver Plumbing Supplies to Central Stores
Term Contract
Post-Bid
$500,000 CJ est. value
Boston, MA 02111

Plumbing Repair Services
Term Contract
Post-Bid
Boston, MA 02203

Repair and Replacement, Broken Pipes and Identified Routine Maintenance
Term Contract
Post-Bid
Boston, MA 02203

Deer Island Wastewater Treatment Facility Roofing Replacement at Various Buildings
Renovation
Post-Bid
$200,000 CJ est. value
Winthrop, MA 02152

Last Updated 09/19/2023 08:37 AM
Project Title

Replace Deaerator D-1

Physical Address View project details and contacts
City, State (County) Boston, MA 02116   (Suffolk County)
Category(s) Single Trades
Sub-Category(s) Plumbing
Contracting Method Competitive Bids
Project Status Sub-Bidding, Construction start expected September 2023
Bids Due View project details and contacts
Estimated Value $1,000,000 [brand] Estimate
Plans Available from Agency's Affiliate
Owner View project details and contacts
Architect View project details and contacts
Description

The United States Department of Agriculture (USDA), Agricultural Research Service (ARS) issues this Request for Proposals (RFP) for a firm fixed-price construction contract to: Replace Deaerator D-1 @ Jean Mayer Human Nutrition Research Center on Aging (HNRCA) 711 Washington St., Boston, MA 02111 SPECIFICATIONS and DRAWINGS ARE AVAILABLE. See Attached The solicitation document, with the incorporated clauses and provisions, is issued in accordance with the Federal Acquisition Regulation (FAR) Parts 15 and 36 and rated in the awarded firm-fixed price order. Interested vendors should reference the solicitation documents for all terms and conditions. No paper solicitation will be available. See solicitation for evaluation factors and submission requirements, sections L and M. Award will be Firm Fixed Price (FFP). The associated NAICS Code is 238220, HVAC and Plumbing Construction. The small business size standard is $18.5 million. Notice of Set-Aside for Small Business Concerns: This requirement is a Total Small Business Set -Aside The Government intends to award one (1) firm fixed-price contract. SELECTION PROCESS: The Proposals will be evaluated using a Lowest Price Technically Acceptable source selection process. Potential offerors will be invited to submit their technical, past , and price information as described in the Solicitation, for review and consideration by the Government. The selection process will evaluate such factors (not necessarily in order): Past , Technical which includes Management & Experience, and Price. Pro Forma information such as bonding and financial capability will also be required to meet the minimum requirements of the solicitation. The Government intends to award a Firm-Fixed Price Contract to the responsible Offeror conforming to the request for proposal that is determined to be the best value to the Government. of Construction is between $500,000 and $1,000,000. Period of is 240 days after receipt of the Notice to Proceed. Bonds: If the contract exceeds $35,000, the offeror to whom award is made shall furnish a security, which can be a or an alternative form per FAR 52.228-13, Alternative Protections. Awards exceeding $150,000 require both and Bonds. A bid bond is required. : An organized has been scheduled for- Thursday 8/24/23 at 8am Participants will meet at - Jobsite Site Contact Joe Curtin Tufts University Facilities Phone: (617) 556-3340 HNRCA, 711 Washington St Boston, MA 02111 ll questions regarding this announcement must be submitted in writing to the Contracting Officer, via email to Mark.Volk@usda.gov. Telephone requests for information will not be accepted or returned. Biobased Products: This procurement requires the use of Biobased products to the extent that such products are reasonably available, meet agency or relevant industry standards, and are reasonably priced. The products should first be acquired from the USDA designated product categories. All supplies and materials shall be of a type and quantity that conform to applicable Federal specifications and standards, and to the extent feasible and reasonable, include the exclusive use of biobased and recycled products. Please www.biopreferred.gov for more information on the USDA Biobased Program and to reference the catalog of biobased products. DISCUSSIONS: The Government intends to award without discussions, but reserves the right to conduct discussions should it be deemed in the Government's best interest. The Government intends to post all notices/amendments related to this solicitation on government point of entry (GPE) Contract Opportunities at https://beta.sam.gov/. All interested firms must be registered on Contract Opportunities web in order to obtain an Award/solicitation documents and all information regarding the solicitation. Hard copies of the solicitation will not be provided. It is the responsibility of the Offeror to check the website daily for any updates/amendments. Offerors are encouraged to check the FBO web site frequently in order to be notified of any changes to this solicitation. IMPORTANT NOTICE: All contractors submitting bids, proposals, or quotes on USDA solicitations must be registered in the System for Award Management (SAM) database. Failure to register in the SAM database will make an Offeror ineligible for award. The SAM website can be accessed at www.sam.gov/portal/SAM. Period of : 09/25/2023 to 05/22/2024 *The value for this project is based on a financial range. The value is listed as the highest possible cost from the range provided by a stakeholder or official project document. Base Bid - Replace D-1 1.1.1 Contractor shall: 1.1.1.1 Demolish existing D-1; pumps and associated valves, strainers, gauges, and flex connections; relief valves; high and low alarm switches; isolation valves; gauge glasses and thermometers; float box; valves and piping between chemical feeder and deaerator; PRV bypass piping and valves; condensate tempering valve (condensate cooler); overflow trap; drain line; control panel; and piping and valves in the condensate inlet and dispose off-. See the limits shown in DA1 Line Drawing (shown in Section 16. Appendix). NOTE: There are two deaerators connected to the boilers. The control panel has toggle switches to choose which deaerator to operate. The panel for Deaerator #2 (D-2) feeds into the control panel for D-1 via relays. Contractor shall ensure that D-2 remains connected to the boilers, and that when D-1 is replaced, the system is reconnected as before. 1.1.1.2 Verify all necessary connections: tie into existing vent piping. 1.1.1.3 Provide and install a new unit, pumps, condensate cooler, control panel, valves, gauges, and other accessories to make a fully functioning deaeration system. See New Unit D-1 Information below. 1.1.1.4 Chemical feed tanks, pump pads, vibration isolation springs, vent, and tank stand shall be reused. Contractor shall run a 1" copper line to the chemical feeder which shall connect to the deaerator below the waterline. 1.1.1.5 Ensure system components will fit into allotted space. 1.1.1.6 Test voltage, connections, and system to demonstrate the system is fully functional. 1.1.1.7 Provide manufacturer start-up. 1.1.1.8 See limits of construction in D-1 Line Drawing, Side View and D-1 Line Drawing, Top View in Section 16. Appendix. The isolation valves shall be replaced.

Details

Division 22 - Plumbing, Common Work Results for Plumbing.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents