Similar Projects
Riverside High School and Middle School Alterations - Electrical Construction
Bidding
Riverside, NJ 08075

Electrical Services
Bidding
Trenton, NJ

2020-2021 Electrical Maintenance Contract - Wastewater Treatment Plant
Term Contract
Post-Bid
Burlington, NJ 08016

General, Electrical, Plumbing, Building & Yard Emergency Services
Term Contract
Post-Bid

New Endeavour Elementary School Solar PV Project
Results
Wrightstown, NJ 08562

High School Parking Lot Light Replacement
Results
Bordentown, NJ 08505

Tesla Charging Stations at Wawa
Pending Verification
Pemberton, NJ 08068

Tesla Charging Stations at Wawa
Pending Verification
Burlington, NJ 08016

On-Call Electrical Services and Repairs at Various Facilities
Term Contract
Bidding
Trenton, NJ

Electrical Contractor Services
Post-Bid
Mount Laurel, NJ 08054

200 KW Generator
Results
Medford, NJ 08055

Burlco Children’S History Center Alteration
Post-Bid
Burlington, NJ 08016

Immediate and Scheduled Electrical Repairs
Term Contract
Results

Install Porch Lights In 50 Apartments Located At Maplewood Homes
Post-Bid
Florence, NJ 08518

New Solar Project at Countryside, Parkway, Fleetwood and Springville Schools
Results
$1,360,000 est. value
Mount Laurel, NJ 08054

Reported 11/06/2019 12:00 AM
Project Title

Extend Overhead Cable Trays

Physical Address View project details and contacts
City, State (County) McGuire AFB, NJ 08562   (Burlington County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Accepting Letters of Interest
Bids Due View project details and contacts
Estimated Value $25,000 to $100,000
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Techical requirements include: Contractor shall install approximately 200ft. of new cable trays/racks continuing off existing cable trays. (Cooper B-Line or equivalent) See attached sketch/drawing. Contractor shall install approximately 14 pull down power cord reels with 30' retractable cord with a 3 gang outlet on the end in proposed locations. See attached sketch/drawing. Contractor shall install (2) 120/208v panels and circuit breakers to accommodate added circuits. New panels shall be installed approximately 40-50ft from existing main panel inside room. The existing main panel within the room shall be the source to energize newly installed panels. (Siemen's or equivalent) Existing panels are Siemen's Contractor shall install sixty three 20 Amp 4gang outlets in proposed locations. (See attached sketch) Upon completion of the job contractor shall test voltages/phasing and assure all installed equipment is completely operational.

Details

Division 26 - Electrical.
Division 27 - Communications, Common Work Results for Communications.
Division 28 - Electronic Safety and Security, Common Work Results for Electronic Safety and Security.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents