Similar Projects
Trinity University Campus
New Construction, Renovation, Addition
Conception
$50,000,000 est. value
San Antonio, TX 78212

Carnahan Canal Renovations at Witte Museum
Renovation
Design
San Antonio, TX 78209

Walgreens Village Medical
Renovation
Design
$500,000 est. value
San Antonio, TX 78225

HVAC Duct Cleaning
Term Contract
Bidding
San Antonio, TX 78236

Roberson HVAC and Equipment Controls Upgrades Project
Alteration
Bidding
San Antonio, TX 78226

HVAC Disposable Air Filters for San Antonio Airport System
Post-Bid
San Antonio, TX 78283

A/C for Central Utility Plant Preventive Maintenance and Repairs
Post-Bid
San Antonio, TX 78216

Maintenance Building Rooftop Air Heater Replacement
Results
Less than $790,000 est. value
San Antonio, TX 78212

Specialized Air Conditioning Maintenance and Repair for IT Spaces (ITSD)
Results
Less than $228,700 est. value
San Antonio, TX 78200

Concord Park III - Medical Office Building
New Construction - 131,000 SF
Construction
$12,000,000 est. value
San Antonio, TX 78258

Aaron's #C0580
Renovation - 18,027 SF
Construction
San Antonio, TX 78230

Draft: Repair Roof and HVAC System at Main CDC Bldg. 2530
Term Contract
Design
San Antonio, TX

Camp Bullis RC HVAC Replacement
Alteration
Bidding
$2,000,000 est. value
San Antonio, TX 78257

HVAC Maintenance Contract
Post-Bid
San Antonio, TX 78230

IAAFA HVAC BLDGS 7353;7355;7358
Results
$500,000 to $1,000,000 est. value
San Antonio, TX 78236

Last Updated 04/29/2022 08:17 AM
Project Title

JBSA Lackland Air Handler Unit

Physical Address View project details and contacts
City, State (County) San Antonio, TX 78275   (Bexar County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Contractor shall remove existing motor and blower assembly. Install 2 Geenheck Model Plenum fans (Vari-green EC motor, dial for balancing) or equal to. Contractor shall modify the electrical to accommodate the new motors for the AHU. Contractor shall retrofit new bower assembly, create a wall in the AHU, and blank off any gaps to create a discharge plenum to be installed. Contractor shall repair any items required for testing the operation of Air Handlers mechanically, and make necessary electrical modifications for new motors at Building 2000 rear mechanical room. Contractor shall supply the materials and service described in this document below. All work shall be conducted in compliance with the American Society of Heating and Air-Conditioning Engineers (ASHRAE) standards. This is a turnkey install and start up. Contract shall result in a fully operational system. 502 CE shall not provide any materials, tools or equipment.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents