The project is located on the east side of Race Street, about 3,000 feet north of Old Church Road within the South Farms research fields of the University of Illinois at Urbana-Champaign. This project shall include the installation of four (4) steel towers (approximately 150 ft tall) and concrete foundations to support a conveyor system for a hyperspectral camera. The project shall include a climate-controlled enclosure/hut for the winch system located next to each tower. A small control structure shall house all controls and electrical gear. Power and data infrastructure shall be provided to each of the enclosures. A parking area for the control structure shall provide an all-weather, firm and stable surface to provide an accessible route from the parking space into the controls trailer. Temporary access route corridors will be provided for Contractor access from Race Street to the control structure and tower locations during construction activities. Upon project completion, all access roads shall be graded smooth and prepped for seeding. Seeding and turf establishment at all disturbed areas is included as a Bid Alternate. The steel towers will be furnished by Others for installation by the Contractor. The cable rigging system and hyperspectral camera shall be furnished and installed by Others. The winch housings will be furnished by Others for installation by the Contractor. The control structure, a job trailer, will be furnished by Others for installation by the Contractor. The control structure and winch houses shall be anchored to foundations constructed by the Contractor. This project shall include the installation of four (4) steel towers approximately 150 ft tall) and concrete foundations to support a conveyor system for a hyperspectral camera. The project shall include a climate-controlled enclosure/hut for the winch system located next to each tower. A small control structure shall house all controls and electrical gear. Power and data infrastructure shall be provided to each of the enclosures. A parking area for the control structure shall provide an all-weather, firm and stable surface to provide an accessible route from the parking space into the controls trailer. Temporary access route corridors will be provided for Contractor access from Race Street to the control structure and tower locations during construction activities. Upon project completion, all access roads shall be graded smooth and prepped for seeding. Seeding and turf establishment at all disturbed areas is included as a Bid Alternate. The steel towers will be furnished by Others for installation by the Contractor. The cable rigging system and hyperspectral camera shall be furnished and installed by Others. The winch housings will be furnished by Others for installation by the Contractor. The control structure, a job trailer, will be furnished by Others for installation by the Contractor. The control structure and winch houses shall be anchored to foundations constructed by the Contractor.

Details

Division 00 - Procurement and Contracting Requirements, Available Project Information, Existing Condition Information.
Division 01 - General Requirements, Temporary Controls, Temporary Erosion and Sediment Control, Facility Services Performance Requirements, Electrical Performance Requirements.
Division 02 - Existing Conditions, Schedules for Existing Conditions, Schedules for Subsurface Investigations.
Division 03 - Concrete, Cast-in-Place Concrete.
Division 05 - Metals, Metal Fabrications.
Division 26 - Electrical, Common Work Results for Electrical, Low-Voltage Electrical Power Conductors and Cables, Grounding and Bonding for Electrical Systems, Hangers and Supports for Electrical Systems, Raceway and Boxes for Electrical Systems, Conduit for Electrical Systems, Identification for Electrical Systems, Switchboards and Panelboards, Low-Voltage Circuit Protective Devices, Fuses, Surge Protective Devices, Surge Protective Devices for Low-Voltage Electrical Power Circuitsrical Power Circuits.
Division 27 - Communications, Common Work Results for Communications.
Division 28 - Electronic Safety and Security, Common Work Results for Electronic Safety and Security.
Division 31 - Earthwork, Site Clearing, Grading, Rough Grading, Finish Grading, Excavation and Fill, Excavation, Structural Excavation for Minor Structures, Fill, Compaction, Erosion and Sedimentation Controls, Bored Piles, Drilled Concrete Piers and Shafts.
Division 33 - Utilities, Sanitary Sewerage Utilities, Site Grounding.