J--Medical Gas Piping Annual PM Detroit VA Medical Center

Physical Address View project details and contacts
City, State (County) Detroit, MI   (Wayne County)
Category(s) Professional Services
Sub-Category(s) Inspection Services
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Medical gas piping inspection services at the John D Dingell VA in Detroit, MI. The contractor shall provide all labor and materials necessary to perform inspection and testing of the medical gas system (oxygen, medical air, vacuum, nitrogen, and nitrous oxide) at the John D. Dingell VA Medical Center, 4646 John R, Detroit, MI, in accordance with all current Joint Commission, (EC.02.05.09) National Fire Protection Association, (NFPA 99, 2012) and all Compressed Gas Association standards. Including all guidelines applicable to an inpatient healthcare facility. The work shall include the following tasks: 1. Master Alarm Panels (3): •Inspect and review of the system for code compliance. •Conduct performance tests to ensure proper function. •Adjust and verify of all set points. 2. Area Alarm Panels (46): •Inspect and review of the system for code compliance. •Conduct performance test for proper function. •Adjust and verify of all set points. 3. Zone Valves (52): • Review codes for compliance and performance tests. • Check for leaks, test for proper labeling, and clean interior of valve boxes. • Verify gauge accuracy/agreement with digital alarm indicator. 4. Gas Outlets (150 panels): • Review codes for compliance and performance tests. • Inspect of all outlets and test the farthest outlet from the zone valve in each zone for proper flow and pressure, function, contaminants, particulates, leaks, cross connection. 5. Manifolds (2): • Review codes for compliance and performance tests. • Test for proper function, test for leaks • Adjust and verify of alarm set points. 6. Medical Air Compressors (2): • Review codes for compliance and conduct performance tests of compressors. • Test medical air for United States Pharmacopoeia (USP) purity and dew point. • Inspect air intake. 7. Medical Vacuum Pumps (3): • Review codes for compliance and conduct performance tests of pumps. • Inspect exhaust outlet 8. Bulk oxygen tank and reserve tank/Manifolds: • Review codes for compliance and performance tests of system. • Inspection per code requirements. • Test for proper function, and alarm leak testing • Adjust and verify of alarm set points.

Details

Division 01 - General Requirements, Quality Control, Testing and Inspecting Services.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents