Similar Projects
Last Updated | 02/04/2023 08:03 AM |
Project Title | Replace Air Handling Units (AHU) S-4 and S-10 - University of Illinois Hospital (UIH) - Division 3, 4 and 5 |
Physical Address | View project details and contacts |
City, State (County) | Chicago, IL 60612 (Cook County) |
Category(s) | Single Trades |
Sub-Category(s) | HVAC |
Contracting Method | Competitive Bids |
Project Status | Contract Award, Construction start expected October 2022 |
Bids Due | View project details and contacts |
Estimated Value | $3,496,249 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The objective of this project is to conduct an end-of-life replacement of air handling units S-10 and S-4, and their associated exhaust-return fans, in the 9th floor penthouse of UI Hospital. This equipment is original to the building construction and exceeds their useful service life. This equipment provides ventilation and thermal comfort to approximately 60,000 square feet of the hospital facility, including main corridors on the entire east side of the building, basement support spaces, and first floor support spaces. Each air handling unit will be replaced with a comparable modular built-up air handling unit in a manner that will allow the existing equipment to continue to operate until a planned cut-over. Existing open space adjacent to the current unit locations will be utilized for project phasing in order to minimize facility impacts. In addition to the AHU replacement work, there is a small auxiliary exhaust fan consolidation scope to manifold the pantry exhausts into a common exhaust header served by a single fan. A bid alternate is included to upgrade the temperature controls components associated with the terminal units served by S-4 and S-10. This work includes replacing the thermostats and actuators within the terminal units (as appliable) with DDC equivalents and incorporating into the building automation system. This Project is located at: University of Illinois Hospital 9th Floor Mechanical Room 1740 W Taylor Street Chicago IL 60612 Contact Information: Kevin Sheehan Project Manager Electronic Bidding Only Chicago, IL 60612 Phone: (312) 415-4652 E-Mail:ksheeh6@uic.edu All responses must include: There is a 30 percent BEP goal for this procurement. See solicitation documentation for details. There is a 3 percent Veteran-owned business goal for this procurement. See solicitation documentation for details. The contract(s) for this solicitation could exceed $50,000 annually. This transaction is subject to the State Board of Elections registration and certification requirements of Public Act 095-0971. The State of Illinois has a policy to encourage prospective vendors to hire qualified veterans, minorities, females, persons with disabilities and ex-offenders. Bid Results - 03-Heating/AC - Ideal Heating Company - $749,555.00 04-Ventilation - R.J. Olmen Company - $2,594,700.00 05-Electricity - Canino Electric Company - $151,994.00 |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |