Similar Projects
ComEd Vault Ventilation (Construction)
Infrastructure
Design
$100,000 to $250,000 est. value
Chicago, IL 60612

RFP - HVAC Repair and Maintenance Services
Term Contract
Bidding
Chicago, IL 60616

Boilers 3, 4, 5 and MCC Replacement Stickney Water Reclamation Plant Rebid
Renovation
Bidding
$17,825,000 CJ est. value
Cicero, IL 60804

Cooling Replacement for Existing AHU (Air Handling Unit) , Oak Park and River Forest High School
Renovation
Sub-Bidding
$500,000 CJ est. value
Oak Park, IL 60302

Black Main - Gym Air Handling Unit (AHU) - DX Coil Replacement and CU installation
Renovation
Sub-Bidding
$25,000 CJ est. value
Chicago, IL 60617

Central Community Center - RTU Replacement (Units 6, 8, 11)
Alteration
Post-Bid
Mount Prospect, IL 60056

Weatherization (IHWAP) Program
Term Contract
Post-Bid

Y1da--537-18-142 Replace Failed S10c AHU for Vascular, SCM, and Urology Construction
Results
$1,000,000 to $2,000,000 est. value
Chicago, IL 60612

Des Plaines HVAC Improvements
Results
Des Plaines, IL

HVAC Replacement and Toilet Room Remodeling
Renovation, Alteration
Post-Bid
Norridge, IL 60706

Morton College Building E - HVAC
Renovation
Results
Less than $100,000 est. value
Cicero, IL 60804

HVAC Roofing Plumbing Sewer Electrical
Infrastructure
Post-Bid
Cicero, IL

J041--*SPECIAL* Hines and Joliet Critical Cooling Repairs
Results
Hines, IL 60141

HVAC Cooling Systems
Alteration
Post-Bid
Riverdale, IL

HVAC Replacement Arlington Heights Memorial Library
Results
Arlington Heights, IL

Last Updated 02/04/2023 08:03 AM
Project Title

Replace Air Handling Units (AHU) S-4 and S-10 - University of Illinois Hospital (UIH) - Division 3, 4 and 5

Physical Address View project details and contacts
City, State (County) Chicago, IL 60612   (Cook County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids
Project Status Contract Award, Construction start expected October 2022
Bids Due View project details and contacts
Estimated Value $3,496,249 [brand] Estimate
Plans Available from Agency's Affiliate
Owner View project details and contacts
Architect View project details and contacts
Description

The objective of this project is to conduct an end-of-life replacement of air handling units S-10 and S-4, and their associated exhaust-return fans, in the 9th floor penthouse of UI Hospital. This equipment is original to the building construction and exceeds their useful service life. This equipment provides ventilation and thermal comfort to approximately 60,000 square feet of the hospital facility, including main corridors on the entire east side of the building, basement support spaces, and first floor support spaces. Each air handling unit will be replaced with a comparable modular built-up air handling unit in a manner that will allow the existing equipment to continue to operate until a planned cut-over. Existing open space adjacent to the current unit locations will be utilized for project phasing in order to minimize facility impacts. In addition to the AHU replacement work, there is a small auxiliary exhaust fan consolidation scope to manifold the pantry exhausts into a common exhaust header served by a single fan. A bid alternate is included to upgrade the temperature controls components associated with the terminal units served by S-4 and S-10. This work includes replacing the thermostats and actuators within the terminal units (as appliable) with DDC equivalents and incorporating into the building automation system. This Project is located at: University of Illinois Hospital 9th Floor Mechanical Room 1740 W Taylor Street Chicago IL 60612 Contact Information: Kevin Sheehan Project Manager Electronic Bidding Only Chicago, IL 60612 Phone: (312) 415-4652 E-Mail:ksheeh6@uic.edu All responses must include: There is a 30 percent BEP goal for this procurement. See solicitation documentation for details. There is a 3 percent Veteran-owned business goal for this procurement. See solicitation documentation for details. The contract(s) for this solicitation could exceed $50,000 annually. This transaction is subject to the State Board of Elections registration and certification requirements of Public Act 095-0971. The State of Illinois has a policy to encourage prospective vendors to hire qualified veterans, minorities, females, persons with disabilities and ex-offenders. Bid Results - 03-Heating/AC - Ideal Heating Company - $749,555.00 04-Ventilation - R.J. Olmen Company - $2,594,700.00 05-Electricity - Canino Electric Company - $151,994.00

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents