Similar Projects
Equipment Operation and Maintenance for The Central Energy Building, Naval Health Clinic, MCAS Cherry Point Nc
Design
Cherry Point, NC

Ronald Wilson Reagan High School HVAC Replacement
Design
Pfafftown, NC 27040

US Cellular Center Mechanical/HVAC Renovation
Post-Bid
Asheville, NC

Installation of 60-ton AAON HVAC Unit
Post-Bid
Beaufort, NC 28516

HVAC Repairs Rachel Freeman School of Engineering
Results
Less than $93,657 est. value
Wilmington, NC 28405

Legacy and Jones Residence Halls Make-up Air
Results
Less than $1,655,170 est. value
Greenville, NC

McEniry HVAC and IT Infrastructure Upgrades
Construction
$10,000,000 est. value
Charlotte, NC 28223

Unc School Of The Arts Residence Hall HVAC Phase 2
Construction
Winston-Salem, NC

Cooling Tower Filtration Project
Post-Bid
Raleigh, NC 27616

EMD Facility HVAC Upgrades
Results
Wilmington, NC

Ionization System
Post-Bid
Eden, Madison, Reidsville, Stoneville, NC

911 Emergency Communication Backup Facility Hvac
Results
Durham, NC 27704

Replace 250 Ton Chiller (#1)
Post-Bid
$250,000 to $500,000 est. value
Cherry Point, NC 28533

Cooler and Freezer Restoration at Durham County Detention Center
Term Contract
Results
Durham, NC 27701

HVAC Preventative Maintenance and Repair Services
Term Contract
Post-Bid
Charlotte, NC 28277

Reported 12/08/2021 12:00 AM
Project Title

HVAC - AG Building

Physical Address View project details and contacts
City, State (County) Carthage, NC   (Moore County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from County Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Each person must wear a mask when in the building. Contractor is responsible to remove all units and trash from County property. Contractor is responsible for the removal and disposable of all freon. Unit can be a Trane or Carrier. Install a new VFD (if one is not included with unit). All high and low voltage to be reconnected and supported with approved fasteners and fused properly. Unit currently has Metasys controls that must be removed and then installed back on the new equipment. Duct detector must be removed from and then installed back on the new equipment and will have to be tested. Include a drain pan under the new unit with a float switch installed and tested.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents