Reported | 01/22/2020 12:00 AM |
Project Title | Vindicator IDS |
Physical Address | View project details and contacts |
City, State (County) | Hurlburt Field, FL 32544 (Okaloosa County) |
Category(s) | Single Trades |
Sub-Category(s) | Security/Communications |
Contracting Method | Competitive Bids. |
Project Status | Request for Quotations |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Upgrade and expand existing Vindicator IDS in building 90748 per diagram provided in Attachment 1. Replace existing 24x24 box with a 30x30 box. Install V-5 panel with PD-16 power supply configuring for two (2) zones of IDS coverage for southern (existing zone) and northern (new zone) part of building. Install BMS and PIN pad on entry door utilizing existing j-boxes and conduit in room 156. Install motion detector near entry door utilizing existing j-box above ceiling. Install BMS on emergency egress door utilizing existing j-boxes and conduit in room 169. Install motion detector near emergency egress door utilizing existing j-box above ceiling in room 169. Total IDS down time for the existing IDS zone covering the southern part of the building must be no more than 8hrs during one normal duty day. A duty day is defined as Monday through Friday 7:00 am – 4:30 pm CST. |
||||