Similar Projects
Last Updated | 03/24/2021 07:01 AM |
Project Title | On-Call Guardrail and Cable Guiderail Repair |
Physical Address | View project details and contacts |
City, State (County) | NC (Iredell County) |
Category(s) | Heavy and Highway |
Sub-Category(s) | Highway Signs/Guardrails/Barriers |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | 1 SP Emergency Call Back Mobilization 100 EA 2 SP Temporary Lane Closure (Nighttime Multi-Lane Divided Facility) 275 EA 3 SP Steel Beam Guardrail Repair 15,000 LF 4 SP Steel Beam Guardrail (Rail only) 150 LF 5 SP Steel Beam Guardrail Repair, Double Faced 150 LF 6 862 Steel Beam Guardrail Terminal Section 2 EA 7 SP Triple Corrugated SB Guardrail Repair (Thrie Beam) 150 LF 8 SP 20" Tubular Triple Corrugated SB Guardrail Repair 150 LF 9 SP Guardrail Anchor Unit - Type III 2 EA 10 SP Guardrail Anchor Unit - Type III Modified 5 EA 11 SP Guardrail Anchor Unit - Type B-83 2 EA 12 SP Guardrail Anchor Unit - Type B-77 2 EA 13 862 Guardrail End Unit – Type CAT-1 8 EA 14 862 Guardrail End Unit - Type AT-1 2 EA 15 SP Buffer End Section CAT-1 (Replacement Part) 8 EA 16 SP Buffer End Section AT-1 (Replacement Part) 2 EA 17 862 Guardrail End Unit - Type XI Modified 2 EA 18 SP Guardrail End Unit - Type TL-3 30 EA 19 SP Guardrail End Unit - Type Median TL-3 3 EA 20 SP Head (Replacement Part – Type TL-3 and TL-3 Median) 5 EA 21 SP Anchor Rail (Replacement Part–Type TL-3 & TL-3 Median) 50 LF 22 SP Steel Hinged Post (Replacement Part-Type TL-3 & TL-3 Median) 2 EA 23 SP 6’ Steel Breakaway Post (weakened) (Replacement Part- Type TL-3 & TL-3 Median) 2 EA 24 SP Additional Guardrail Post (steel) 100 EA 25 SP Additional Guardrail Post (wood) 10 EA 26 SP Additional Guardrail Weak Post 10 EA 27 SP Additional Block (wood or plastic) 100 EA 28 SP Steel Beam Guardrail Transition Section - DBL Face Weak to DBL Face Normal 2 EA 29 SP Guardrail WTR Steel Transition Section 5 EA 30 862 Triple Corrugated SB Guardrail Terminal Sections 2 EA 31 SP Typical End Shoe 4 EA 32 863 Remove Existing Guardrail 250 LF 33 SP Impact Attenuator Unit, Type TL-3 (Non-Gating) 1 EA 34 SP Impact Attenuator Unit, Type TL-3 (Gating) 1 EA 35 SP Remove & Stockpile Existing Guardrail 250 LF 36 864 Remove and Reset Existing Steel Beam Guardrail 250 LF 37 SP Remove and Reset Existing Guardrail End Unit 2 EA 38 SP Additional Guardrail Delineator 250 EA 39 SP Cable Guiderail Repair 30,000 LF 40 SP Cable Guiderail Splice 10 EA 41 SP Cable-Rail (cable wire) 250 LF 42 SP Cable Guiderail Retensioning (Each Cable) 10 EA 43 864 Remove and Reset Existing Cable Guiderail 250 LF 44 SP Additional Cable Guiderail Delineator 100 EA 45 SP Cable Guiderail Anchor Post 20 EA 46 SP Cable Guiderail Spring Cable End Assembly 8 EA 47 SP Additional Cable Guiderail Intermediate Post 25 EA 48 SP Cable Guiderail Anchor Unit 1 EA 49 SP Cable Guiderail Breakaway Anchor Angle 2 EA 50 SP Cable Guiderail Turnbuckle Assembly 2 EA 51 SP Additional Cable Guiderail Hook Bolt 25 EA 52 SP Additional Cable Guiderail End Post Cap 5 EA 53 SP Cable Guiderail End Post Bearing Plate 5 EA |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |