Similar Projects
Exterior Finishing Work
Alteration
Post-Bid
$669,000 est. value
Kiryas Joel, NY

New Roof and Stucco Work at Fire Station 1
Alteration
Post-Bid
Wappinger, NY 12590

Z1DA--528A8-19-802 HOSPITAL FACADE REPAIRS PHASE 2A
Results
$1,000,000 to $5,000,000 est. value
Albany, NY

Gleeson and Laffin Halls Facade Investigation & Repair
Results
$1,000,000 to $2,500,000 est. value
Farmingdale, NY 11735

Williamson CSD Capital Outlay Project 2021-22
Alteration
Post-Bid
Williamson, NY 14589

Hostel 10538 Windows and Siding Replacement
Alteration
Results
$175,000 to $225,000 est. value
Shushan, NY 12873

Roofing, Railing Replacement and Rooftop Structure at Seth Low House
Alteration
Post-Bid
Brooklyn, NY 11212

CDBG Funded Exterior Improvements
Alteration
Results
Elmont, NY 11003

Building 77 Facade
Term Contract
Post-Bid
Brooklyn, NY 11205

Town Hall Sign Replacement
Alteration
Results
$60,000 est. value
West Seneca, NY

Exterior Improvements at Buffalo Psychiatric Center - Buildings 70 and 78
Alteration
Post-Bid
$150,000 to $200,000 est. value
Celoron, NY 14720

West Apartments Building C Stucco Replacement
Alteration
Results
Stony Brook, NY 11790

Deck Joint Sealing - LPGP
Alteration
Post-Bid
Lewiston, NY 14092

Roosevelt Community Facade and Stair Tower Repairs
Alteration
Results
Stony Brook, NY 11790

Marcy Casino Stair Replacement
Alteration
Post-Bid
Buffalo, NY 14222

Last Updated 07/10/2023 03:14 PM
Project Title

Generator Design and Installation

Physical Address View project details and contacts
City, State (County) Potsdam, NY 13676   (Saint Lawrence County)
Category(s) Single Trades
Sub-Category(s) Finishes/Exterior
Contracting Method Competitive Bids
Project Status Sub-Bidding, Construction start expected August 2023
Bids Due View project details and contacts
Estimated Value $100,000 [brand] Estimate
Plans Available from Agency's Affiliate
Owner View project details and contacts
Architect View project details and contacts
Description

Leroy St SOIRA Generator Design and Installation This project consists of the installation of a whole house generator. The vendor shall provide all labor and materials necessary to complete the work in a professional manner according to scope of work and architectural drawings supplied. All questions or requests for information shall be submitted, in writing to Mark.g.woods@opwdd.ny.gov. 1. Vendor to furnish new Generac 25KW 120/240V single phase natural gas generator (including block heater) and Generac 400 Amp ATS (service entrance rated). 2. Contractor shall install generator, ATS, and all accessories EXCLUDING block heater. Reference Generac installation manual for all installation details. 3. The contractor will arrange for and fund a factory representative to install the block heater and perform the generator start-up. Contractor shall assist during generator start-up as needed. 4. Contractor shall make all final connections to all control and owner-supplied equipment as required. 5. Wiring shall be type THWN or THW unless otherwise noted on applicable drawings. 6. Provide control wiring as per manufacturer recommendation. 7. Provide electrical system grounding in accordance with the NEC and all applicable local codes. 8. All generator related conduits passing through walls or foundations are to be appropriately sleeved and sealed. Any existing penetrations shall also be sealed. 9. All indoor boxes and enclosures shall be NEMA 250 Type 1. 10.Provide all necessary signage and labels as required by code. 11.All indoor conduits shall be EMT. All outdoor conduits shall be galvanized steel rigid metal conduit. 12.Coordinate electrical and natural gas work with service providers, ensuring all requirements and standards are met. 13.Contractor shall be responsible for recording conduit paths and sizes in shop drawings and as-builts. 14.Electrical contractor shall verify field conditions prior to submitting bid. 15.Electrical contractor shall obtain and pay for both rough and final underwrites or other approved inspection agency certificates of electrical inspection. These certificates shall be presented prior to request for final payment. 16.The design shall be based on initial site visit data. Electrical contractor to supply install feeders, fuses and C.B. to match the name plate rating of all equipment. This shall be included in the initial bid proposal and no extras shall be entertained. 17.Prior to digging contractor shall notify Dig Safe New York in accordance with New York State Law and determine locations of all utilities. Provide 72 hour noticed in advance to 1-800-962-7962, coordinate all digging with owner representatives. 18.At utility crossings-Excavate trench with caution at these locations. The contractor will be responsible for repairing any damaged utilities and landscaping. 19.All indoor conduits shall be EMT. Underground conduit shall be PVC schedule 80 and burial depth shall be 18" per NEC table 300.5. 20.Contractor shall provide NEMA 3R waterproof junction box of the exterior wall of the building. 21.Provide 6" thick concrete pad for standby generator. Concrete pad shall be 6" wider and 6" longer than the generator weatherproof enclosure. 22.Contractor to coordinate locations of all utilities with utility provider. Locations shown are approximate and have been plotted. 23.Contractor to coordinate with utility provider to install the appropriate gas meter and any feed associated with upsizing the meter are the contractor's responsibility.

Details

Division 09 - Finishes.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents