Similar Projects
Electrical Contractor Services
Post-Bid
Covington, KY

NFPA Sprinkler and Fire Pump Inspections
Post-Bid
Erlanger, KY 41018

Fire Alarm Inspections
Results
Florence, KY

Sawyer Hayes Conference Center Chiller Replacement
Renovation
Post-Bid
Less than $434,149 est. value
Louisville, KY 40241

P & DC Fire Alarm Systems Upgrades
Post-Bid
$1,100,000 to $1,300,000 est. value
Louisville, KY

Jeffersonian Fire Alarm System Installation
Post-Bid
$35,000 to $40,000 est. value
Jeffersontown, KY 40299

Helipad Fire Suppression System
Results
Less than $250,000 est. value
Lexington, KY

Smoke Alarm
Term Contract
Post-Bid
Lexington, KY

DOC - NTC Fire Door Replacement
Results
Less than $87,800 est. value
Burgin, KY

Lake Barkley Lodge Complex Life Safety Upgrades Fire Alarm
Results
$398,000 est. value
Cadiz, KY 42211

Shelby County High School - BP 14 Fire Protection
Results
Shelbyville, KY 40065

Last Updated 04/02/2021 01:35 AM
Project Title

Jenny Wiley Lodge Complex Life Safety Upgrades

Physical Address View project details and contacts
City, State (County) Prestonsburg, KY   (Floyd County)
Category(s) Single Trades
Sub-Category(s) Fire Protection
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $230,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The Fire Alarm Life Safety System of the Lodge, Guest Room Buildings "A through D", Pool Restroom Building, as well as the Meeting Room Building will be upgraded per the Kentucky Building Code with Current Revisions Americans with Disabilities Act, International Building Code, National Fire Alarm and Signaling Code NFPA72, and National Electrical Code. An intelligent, addressable fire alarm system shall be provided in accordance with National Fire Alarm and Signaling Code requirements as well as the requirements of the State Fire Marshall’s Office. The system will comply with all manufacturers’ requirements and shall report compatible alarm signals to the remote central system via an externally mounted dialer. The fire alarm system will monitor any and all sprinkler system flow switches, tamper switches, kitchen hood monitor, elevator recall, and duct mounted smoke detectors as well as heat detectors and smoke detectors. Power panels serving the fire alarm system shall receive SPD "surge suppression devices" on the 120VAC power feeder to protect the fire alarm system from transient voltages and power surges. A 48 hour notification is required for any outage of the existing Fire Alarm System. All work shall be done in compliance with the KBC "Kentucky Building Code", the IBC "International Building Code" and NEC "National Electrical Code.

Details

Division 21 - Fire Suppression.
Division 28 - Electronic Safety and Security, Fire Detection and Alarm.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents