Similar Projects
Roofing Envelope Services
Post-Bid

Louis Rings Residence Roof Replacement and Exterior Renovations
Post-Bid
Less than $160,000 est. value
Dublin, OH 43016

AFICC Enterprise Wide Roofing Repair, Replacement, and Maintenance (R3M)
Results

MATOC - Army Reserve National Roofing Program (NRP)
Results
Less than $95,000,000 est. value

Roofing Repair and Maintenance
Post-Bid

Schottenstein - Lower Roof Replacement
Results
Less than $1,593,000 est. value
Columbus, OH

Roofing Repair and Emergency Service
Results
Columbus, OH

2020 Roof Improvements
Results
Less than $444,962 est. value
Dublin, OH 43017

Police Station Roof Replacement
Results
Worthington, OH 43085

City Facility Roof Renovations-Phase 1
Results
Columbus, OH

1150 E Main Street - Central Community House
Results
Columbus, OH

Adventure Center Roof, Canopy & Facelift
Results
Columbus, OH 43203

CSC-20013; Gutter and Roof Repair
Results
$500,000 to $1,000,000 est. value
Columbus, OH 43218

Roof Redirection - Clintonville 1 Blenheim / Glencoe, Area 2
Results
Columbus, OH

Fix It - Roof Upgrades at Centennial HS - Phase II Project
Results
Less than $1,400,000 est. value
Columbus, OH 43211

Last Updated 11/01/2021 02:16 AM
Project Title

DRWP-2021-Roofing and Gutter Service-MD10182021

Physical Address View project details and contacts
City, State (County) Columbus, OH 43215   (Franklin County)
Category(s) Single Trades
Sub-Category(s) Roofing
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Fabrication/Weld Shop Building: install properly fitted high temperature boots as needed on round penetrations (specific to hot gas vents) through metal roofing system. Replace flashing on 4” Dia. B-Vent and replace rain cap on the Inferred Heater Exhaust just above the Small Metal Lathe at the East end of the Machine Shop. Work to include outline below. Access work area via exterior ladder. 1. Set up safety per OSHA standards - swivel metal roof anchors. 2. Remove coating along seams and panels on all the roof vents as needed, near penetrations with wire wheel. Treat with rust inhibitor/red oxide primer and galvanizing spray. 3. Remove existing pipe boot at active leak area. Furnish and install new patch panel (24 Ga Galvalume R Panel WPRP, Weathered Zinc) over existing damaged panel and seal with butyl weathertight. Furnish and install new pipe boot per manufacturer's specifications. 4. Thoroughly inspect roof for missing, damaged or backed out fasteners as necessary. 5. Clean up and remove all job-related material, trash and debris. Boot Flashing Material: All Boot Flashing for round duct hot gas vents shall be able to withstand 437 Deg. F continuous. All Fasteners will be stainless steel. 920 Hypo Chlorite Building: Gutter repair is needed on this building to include the following. 1. Access work area via aerial work platform. 2. Set up safety per OSHA guidelines. 3. Clean and inspect gutters on building. 4. Remove existing fasteners at each gutter lap, end cap and downspout drop. Remove existing sealant and prepare surface for new sealant. 5. Install permaseal gutter sealant at each lap, end cap and downspout drop. Install new fasteners. Add supplementary gutter hangers or fasteners as necessary to prevent sagging

Details

Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents