Similar Projects
Cooling Treatment Maintenance Services
Post-Bid
Jonesboro, Riverdale, GA 30236

HVAC Replacement and Related Work Parkview Extension Homes
Post-Bid
Athens, GA 30601

HVAC Services 2019
Term Contract
Results
Warner Robins, GA

Construction Management at Risk Services Watson Cooling Tower Replacement
Results
Less than $275,000 est. value
Statesboro, GA

Warren County HVAC
Construction
Warrenton, GA 30828

BCCCA HVAC and Lighting Replacement
Post-Bid
Cartersville, GA 30121

HVAC Filter Change-Out
Term Contract
Results
Adairsville, GA

Aubrey Street Recreational Gymnasium HVAC System
Post-Bid
Cartersville, GA 30120

New HVAC System for PE Facility
Results
Sandersville, GA

HVAC Renovations for South Douglas Elementary
Post-Bid
Less than $1,000,000 est. value
Douglasville, GA 30135

HVAC Services
Results
Norcross, GA 30071

HVAC Ingram Pye Elementary School
Post-Bid
Macon, GA 31204

Cedartown High School HVAC Modifications
Results
Cedartown, GA 30125

HVAC Maintenance Contract 2019-2021
Term Contract
Post-Bid
Waynesboro, GA

Commercial Kitchen Walk-In Freezer and Cooler Replacement
Results
Less than $229,500 est. value
Lawrenceville, GA 30046

Last Updated 09/11/2020 10:29 AM
Project Title

EMA Headquarters HVAC Replacement

Physical Address View project details and contacts
City, State (County) Waynesboro, GA 30830   (Burke County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

DEMOLITION: Remove existing Trane 10ton split heat pump system and dispose of. (The refrigerant must be recovered according to EPA regulations and requirements. No venting of the refrigerant will be allowed. INSTALLATION: Install New Carrier 10 Ton Split Heat Pump HVAC System Two Carrier 5Ton Heat Pumps M#25HCE460AP05 with Winter Start Control, Carrier 10Ton Air Handler M# 40RUQA12T2A5-0A0A0, Staged 25kw Electric Strip Heater M#CAELHEAT010A00, Reuse Existing Wall Thermostat. 1. Replace rusted outdoor disconnects and electrical wire and connections to outdoor units. 2. Confirm existing refrigerant lines meet new system requirements. 3. Flush refrigerant lines and clean before reconnecting system if reusing existing line sets. 4. Contractor’s warranty must cover the new equipment and associated work only for 1 year. 5. Manufacturer Equipment warranty to cover 5 year all parts including compressor. Demolition and disposal of existing equipment is the contractor’s responsibility. Contractor to observe EPA guidelines in recovering and disposing of refrigerant from existing HVAC equipment. 6. Shall include all electrical requirements for a complete operable system per code 7. Verify dimensions of new units prior to installation.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents