Similar Projects
Last Updated | 03/18/2021 06:59 AM |
Project Title | Installation and Repair of Guardrail, Cable Guiderail, Impact Attenuators, Bridge Rail, Fence and Concrete Barrier Walls on I-77, I-85, I-485, I-277, US 74, NC 16 and the Monroe Expressway |
Physical Address | View project details and contacts |
City, State (County) | Monroe, NC (Cabarrus, Mecklenburg, Union Counties) |
Category(s) | Heavy and Highway |
Sub-Category(s) | Highway Signs/Guardrails/Barriers |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | WBS ELEMENT NO.: 40.2.2 and 40.2.9 1 Sp Steel Bm Guardrail 1,000 Lf 2 Sp Steel Bm Guardrail Repair 18,000 Lf 3 864 Remove & Reset Existing Guardrail 500 Lf 4 863 Remove Existing Guardrail 300 Lf 5 Sp Triple Corrugated Guardrail Repair 300 Lf 6 862 Triple Corrugated Guardrail Terminal Sections 5 Ea 7 862 w-Tr Steel Bm Guardrail Transition Sections 10 Ea 8 Sp Additional Guardrail Posts (Steel) 500 Ea 9 Sp Additional Guardrail Posts (Wood) 100 Ea 10 Sp Bridge Or Barrier Wall Anchor Units 25 Ea 11 862 Guardrail End Units, Type Cat-1 25 Ea 12 Sp Guardrail End Units, Type Tl-3 100 Ea 13 Sp Buffered End Section For At-1, Cat-1 10 Ea 14 Sp Head (Replacement Part-Type Tl-3) 10 Ea 15 Sp Anchor Rail (Replacement Part-Type Tl-3) 10 Ea 16 Sp Cable (Greu Tl-3 & Cat-1) 10 Ea 17 Sp Steel Hinged Post (Replacement Parttype Tl-3) 10 Ea 18 Sp 6’ Steel Breakaway Post, Weakend 10 Ea 19 Sp Impact Attenuator Unit, Type Tl-3 (Nongating 24” Wide) 6 Ea 20 Sp Impact Attenuator Unit, Type Tl-3 (Nongating 30” Wide) 4 Ea 21 Sp Impact Attenuator Unit, Type Tl-3 (Nongating 60” Wide) 2 Ea 22 Sp Impact Attenuator Unit, Type Tl-3 (Gating 24” Wide) 3 Ea 23 Sp Repair Impact Attenuator Unit, Type 350 (Non-Gating 24” Wide) 6 Ea 24 Sp Repair Impact Attenuator Unit, Type 350 (Non-Gating 30” Wide) 5 Ea 25 Sp (Non-Gating 60” Wide) 2 Ea 26 Sp Repair Impact Attenuator Unit, Type 350 (Gating 24” Wide) 4 Ea 27 Sp Impact Attenuator Unit, Type 350 Smart Cushion 24” 4 Ea 28 Sp Impact Attenuator Unit, Type 350 Smart Cushion 30” w Transition 1 Ea 29 Sp Impact Attenuator Unit, Type 350 Smart Cushion 60” w Transition 1 Ea 30 Sp Impact Attenuator Unit, Type 350 Smart Cushion 90” w Transition 1 Ea 31 Sp Repair Smart Cushion 15 Ea 32 Sp Cable Guiderail Repair 30,000 Lf 33 Sp Retension Cable Guiderail(Each Cable) 150 Ea 34 Sp Cable Guiderail, Anchor Post 40 Ea 35 Sp Cable Guiderail Anchor Units 5 Ea 36 Sp Cable Guiderail Hook Bolts 350 Ea 37 Sp Cable Guiderail Splice 5 Ea 38 Sp Cable Guiderail Compensating Device (Spring) 10 Ea 39 Sp High Tension Cable Post 200 Ea 40 Sp Retension High Tension Cable (Each Cable) 20 Ea 41 Sp High Tension Cable Anchor 3 Ea 42 Sp High Tension Cable Splice 4 Ea 43 Sp Concrete Wall Repair (Less Than 1 Cy) 2 Cy 44 Sp Concrete Wall Repair (1-3 Cy) 30 Cy 45 Sp Concrete Wall Repair (Over 3 Cy) 60 Cy 46 Sp Supplying Concrete After Hours 5 Ea 47 Sp Remove And Replace Post (2 Bar Metal Bridge Rail) 20 Ea 48 Sp Remove And Replace Elliptical Rail (Each Bridge Rail) 300 Lf 49 866 Woven Wire Fence, 48” Fabric 1,000 Lf 50 866 4” Timber Fence Post, 7’-6” Long 100 Ea 51 866 5” Timber Fence Post, 8’-0” Long 25 Ea 52 Sp Emergency Repair 4 Hour Response 25 Ea 53 Sp Emergency Repair 24 Hour Response 150 Ea 54 Sp Lane Closure (Daytime) 5 Ea 55 Sp Lane Closure (Nighttime) 60 Ea 56 Sp Ramp Closure (Day/Night) 25 Ea 57 Sp Shoulder Closure (Day/Night) 500 Ea |
||||||
Details |
|
||||||
Bidder's List | View project details and contacts | ||||||
Prospective Bidders | View project details and contacts | ||||||
Project Documents |
![]() Engineered Spec Sheet ![]() Architectural Plans ![]() Other Documents |