Similar Projects
Last Updated 04/03/2019 06:00 AM
Project Title

Traffic OPS Improvement

Physical Address View project details and contacts
City, State (County) (Brevard, Flagler, Lake, Marion, Orange, Osceola, Seminole, Sumter, Volusia Counties)
Category(s) Heavy and Highway
Sub-Category(s) Traffic Signalization
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description Work Document driven quick response contract for installing traffic operational improvements such as: new traffic signals, electronic signs, resolving unexpected problems concerning with signalization, loop assembly repairs, new pedestrian crosswalks and pedestrian feature installations. Section 0001 Roadway 0102- 14- Traffic Control Officer Hr 50.000 0102- 60- Work Zone Sign Ed 1,000.000 0102- 74- 1 Channelizing Device- Types i, Ii, Di, Vp, Drum, Or Lcd Ed 1,000.000 0102- 76- Arrow Board / Advance Warning Arrow Panel Ed 1,000.000 0102- 99- Portable Changeable Message Sign, Temporary Ed 300.000 0102-104- Temporary Signalization And Maintenance, Intersection Ed 50.000 0102-107- 1 Temporary Traffic Detection And Maintenance,IntersectionEd 50.000 0110- 2- 1 Clearing & Grubbing (Push Button Contract) Ac 1.000 0110- 4- 10 Removal Of Existing Concrete Sy 1,000.000 0120- 1- Regular Excavation Cy 100.000 0120- 2- 2 Borrow Excavation, Truck Measure Cy 100.000 0520- 1- 7 Concrete Curb & Gutter, Type e Lf 100.000 0520- 1- 10 Concrete Curb & Gutter, Type f Lf 100.000 0520- 2- 2 Concrete Curb, Type b Lf 75.000 0520- 2- 4 Concrete Curb, Type d Lf 75.000 0520- 5- 11 Traffic Separator Concrete-Type i, 4` Wide Lf 100.000 0520- 5- 12 Traffic Separator Concrete-Type i, 6` Wide Lf 100.000 0520- 5- 16 Traffic Separator Concrete- Type i, 8.5` Wide Lf 100.000 0520- 5- 21 Traffic Separator - Concrete, Type Ii, 4` Wide Lf 100.000 0520- 5- 22 Traffic Separator - Concrete, Type Ii, 6` Wide Lf 100.000 0520- 5- 26 Traffic Separator Concrete- Type Ii, 8.5` Wide Lf 100.000 0520- 5- 41 Traffic Separator Concrete- Type Iv, 4` Wide Lf 100.000 0520- 5- 42 Traffic Separator Concrete- Type Iv, 6` Wide Lf 100.000 0520- 5- 46 Traffic Separator Concrete- Type Iv, 8.5` Wide Lf 100.000 0520- 70- Concrete Traffic Separator, Special- Variable Width Sy 100.000 0522- 1- Concrete Sidewalk And Driveways, 4" Thick Sy 100.000 0522- 2- Concrete Sidewalk And Driveways, 6" Thick Sy 100.000 0527- 2- Detectable Warnings Sf 200.000 0570- 1- 2 Performance Turf, Sod Sy 200.000 Section 0002 Signing 0700- 1- 11 Single Post Sign, f&i Ground Mount, Up To 12 Sf As 10.000 0700- 1- 12 Single Post Sign, f&i Ground Mount, 12-20 Sf As 10.000 0700- 1- 13 Single Post Sign, f&i Ground Mount, 21-30 Sf As 2.000 0700- 1- 50 Single Post Sign, Relocate As 10.000 0700- 1- 60 Single Post Sign, Remove As 10.000 0700- 2- 11 Multi- Post Sign, f&i Ground Mount, Up To 12 Sf As 2.000 0700- 2- 12 Multi- Post Sign, f&i Ground Mount, 12-20 Sf As 2.000 0700- 2- 13 Multi- Post Sign, f&i Ground Mount, 21-30 Sf As 2.000 0700- 2- 50 Multi- Post Sign, Ground Mount, Relocate As 2.000 0700- 2- 60 Multi- Post Sign, Remove As 2.000 0700- 3-101 Sign Panel, Furnish & Install Ground Mount, Up To 12 Sf Ea 10.000 0700- 3-102 Sign Panel, Furnish & Install Ground Mount, 12-20 Sf Ea 2.000 0700- 3-103 Sign Panel, Furnish & Install Ground Mount, 21-30 Sf Ea 2.000 0700- 3-201 Sign Panel, Furnish & Install Overhead Mount, Up To 12 Sf Ea 2.000 0700- 3-202 Sign Panel, Furnish & Install Overhead Mount, 12-20 Sf Ea 2.000 0700- 3-203 Sign Panel, Furnish & Install Overhead Mount, 21-30 Sf Ea 2.000 0700- 3-501 Sign Panel, Relocate, Up To 12 Sf Ea 2.000 0700- 3-601 Sign Panel, Remove, Up To 12 Sf Ea 2.000 0700- 3-602 Sign Panel, Remove, 12-20 Sf Ea 2.000 0700- 3-603 Sign Panel, Remove, 21-30 Sf Ea 2.000 0700- 5- 21 Internally Illuminated Sign, Furnish & Install OverheadMount, Up To 12 SfEa 4.000 0700- 5- 22 Internally Illuminated Sign, Furnish & Install, OverheadMount, 12-18 SfEa 4.000 0700- 5- 40 Internally Illuminated Sign, Install- Furnished By Fdot Ea 5.000 0700- 5- 50 Internally Illuminated Sign, Relocate Ea 5.000 0700- 5- 60 Internally Illuminated Sign, Remove Ea 5.000 0700- 11-112 Electronic Display Sign, Furnish & Install Ground MountacPowered, Electronic Warning Sign, 12-20 SfAs 1.000 0700- 11-122 Electronic Display Sign, Furnish & Install Ground MountacPowered, Electronic Regulatory Sign, 12-20 SfAs 1.000 0700- 11-131 Electronic Display Sign, Furnish & Install Ground MountacPowered, Speed Feedback Sign, Up To 12 SfAs 1.000 0700- 11-132 Electronic Display Sign, Furnish & Install Ground MountacPowered, Speed Feedback Sign, 12-20 SfAs 1.000 0700- 11-141 Electronic Display Sign, Furnish & Install Ground MountacPowered, Elect Warning w/Flashing Beacon, Up To 12 SfAs 1.000 0700- 11-142 Electronic Display Sign, Furnish & Install Ground MountacPowered, Elect Warning w/Flashing Beacon, 12-20 SfAs 1.000 0700- 11-151 Electronic Display Sign, Furnish & Install Ground MountacPowered, Elect Regulatory w/Flashing Beacon, Up To12 SfAs 1.000 0700- 11-152 Electronic Display Sign, Furnish & Install Ground MountacPowered, Elect Regulatory w/Flashing Beacon, 12-20SfAs 1.000 0700- 11-161 Electronic Display Sign, Furnish & Install Ground MountacPowered, Speed Feedback w/Flashing Beacon, Up To 12SfAs 1.000 0700- 11-162 Electronic Display Sign, Furnish & Install Ground MountacPowered, Speed Feedback w/Flashing Beacon, 12-20 SfAs 1.000 0700- 11-222 Electronic Display Sign, Furnish & Install Ground MountsolarPowered, Electronic Regulatory Sign, 12-20 SfAs 1.000 0700- 11-231 Electronic Display Sign, Furnish & Install Ground MountsolarPower, Speed Feedback, Up To 12 SfAs 1.000 0700- 11-241 Electronic Display Sign, Furnish & Install Ground MountsolarPower, Elect Warning w/Flashing Beacon, Up To 12SfAs 1.000 0700- 11-251 Electronic Display Sign, Furnish & Install Ground MountsolarPowe, Elect Regulatory w/Flashing Beacon, Up To12 SfAs 1.000 0700- 11-261 Electronic Display Sign, Furnish & Install Ground MountsolarPowe, Speed Feedback w/Flashing Beacon, Up To 12SfAs 1.000 0700- 11-321 Electronic Display Sign, Furnish & Install OverheadMount- Ac Powered, Regulatory Sign, Up To 12 SfAs 1.000 0700- 11-391 Electronic Display Sign, Furnish & Install OverheadMount- Ac Powered, Blank Out Sign, Up To 12 SfAs 1.000 0700- 11-500 Electronic Display Sign, Relocate As 1.000 0700- 11-600 Electronic Display Sign, Remove- Ground Mount As 2.000 0700- 11-700 Electronic Display Sign, Remove- Overhead Mount As 1.000 0700- 12- 11 Sign Beacon, f&i Ground Mount- Ac Powered, One Beacon As 1.000 0700- 12- 12 Sign Beacon, f&i Ground Mount- Ac Powered, Two Beacons As 1.000 0700- 12- 21 Sign Beacon, f&i Ground Mount- Solar Powered, OneBeaconAs 1.000 0700- 12- 22 Sign Beacon, f&i Ground Mount- Solar Powered, TwoBeaconsAs 1.000 0700- 12- 50 Sign Beacon, Relocate Beacon- Sign To Remain As 2.000 0700- 12- 60 Sign Beacon, Remove Beacon- Sign To Remain As 2.000 0705- 11- 1 Delineator, Flexible Tubular Ea 100.000 0706- 3- Retro-Reflective/Raised Pavement Markers Ea 200.000 0710- 11-131 Painted Pavement Markings, Standard, White, Skip, 10-30Or 3-9 Skip, 6" WideGm 0.500 0710- 11-133 Painted Pavement Marking, Standard,White, 3`-9` Skip DropLine And Approach To Toll Plaza, 12" Wide,Gm 0.500 0710- 11-141 Painted Pavement Markings, Standard, White, 2-4 DottedGuideline/ 6-10 Dotted Extension, 6"Gm 0.500 0710- 11-231 Painted Pavement Markings, Standard, Yellow, Skip, 6" Gm 0.500 0711- 11-102 Thermoplastic, Standard, White, Solid, 8" ForInterchange And Urban IslandGm 0.250 0711- 11-123 Thermoplastic, Standard, White, Solid, 12" For CrosswalkAnd RoundaboutLf 800.000 0711- 11-124 Thermoplastic, Standard, White, Solid, 18" For DiagonalsAnd ChevronsLf 800.000 0711- 11-125 Thermoplastic, Standard, White, Solid, 24" For Stop LineAnd CrosswalkLf 600.000 0711- 11-141 Thermoplastic, Standard, White, 2-4 Dotted Guideline/ 6-10Gap Extension, 6"Gm 0.500 0711- 11-160 Thermoplastic, Standard, White, Message Or Symbol Ea 8.000 0711- 11-170 Thermoplastic, Standard, White, Arrow Ea 8.000 0711- 11-224 Thermoplastic, Standard, Yellow, Solid, 18" For DiagonalOr ChevronLf 450.000 0711- 14-123 Thermoplastic, Preformed, White, Solid, 12" ForCrosswalkLf 800.000 0711- 14-125 Thermoplastic, Preformed, White, Solid, 24" ForCrosswalkLf 600.000 0711- 14-560 Thermoplastic, Preformed, White With Black Contrast OnConcrete Pavement, Message Or SymbolEa 5.000 0711- 14-570 Thermoplastic, Preformed, White With Black Contrast,Arrow On Concrete SurfaceEa 5.000 0711- 14-660 Thermoplastic, Preformed, Multi Color Route Shield Ea 5.000 0711- 15-101 Thermoplastic, Standard-Open Graded Asphalt SurfacesWhite, Solid, 6"Gm 0.500 0711- 15-131 Thermoplastic, Standard-Open Graded Asphalt Surfaces,White, Skip, 6",10-30 Skip Or 3-9 Lane DropGm 0.500 0711- 15-201 Thermoplastic, Standard-Open Graded Asphalt Surfaces,Yellow, Solid, 6"Gm 0.500 0711- 15-231 Thermoplastic, Standard-Open Graded Asphalt Surfaces,Yellow, Skip, 6"Gm 0.500 0711- 16-131 Thermoplastic, Other Surfaces, White, Skip, 6",10-30 Skip Or3-9 Lane DropGm 0.500 0711- 16-133 Thermoplastic, Standard-Other Surfaces White, Skip, 12"-Approach To Toll Plaza Or 3-9 Lane DropGm 0.500 0711- 16-202 Thermoplastic, Standard-Other Surfaces, Yellow, Solid,8"Gm 0.250 0711- 17- Thermoplastic, Remove Existing Thermoplastic PavementMarkings: Non-Conflicting OnlySf 1,000.000 Section 0003 Signalization 0630- 2- 11 Conduit, Furnish & Install, Open Trench Lf 1,000.000 0630- 2- 12 Conduit, Furnish & Install, Directional Bore Lf 1,000.000 0630- 2- 14 Conduit, Furnish & Install, Aboveground Lf 1,000.000 0632- 7- 1 Signal Cable- New Or Reconstructed Intersection,Furnish & InstallPi 5.000 0632- 7- 2 Signal Cable- Repair/Replace/Other, Furnish & Install Lf 1,000.000 0632- 7- 4 Signal Cable, Adjust Pi 5.000 0632- 7- 6 Signal Cable, Remove- Intersection Pi 5.000 0632- 7- 7 Signal Cable, Remove- Outside Of Intersection Lf 1,000.000 0633- 1-111 Fiber Optic Cable, f&i, Overhead,2-12 Fibers Lf 1,000.000 0633- 1-112 Fiber Optic Cable, f&i, Overhead,13-48 Fibers Lf 1,000.000 0633- 1-113 Fiber Optic Cable, f&i, Overhead,49-96 Fibers Lf 1,000.000 0633- 1-114 Fiber Optic Cable, f&i, Overhead,97-144 Fibers Lf 1,000.000 0633- 1-121 Fiber Optic Cable, f&i, Underground,2-12 Fibers Lf 1,000.000 0633- 1-122 Fiber Optic Cable, f&i, Underground,13-48 Fibers Lf 1,000.000 0633- 1-123 Fiber Optic Cable, f&i, Underground,49-96 Fibers Lf 1,000.000 0633- 1-124 Fiber Optic Cable, f&i, Underground, 97 - 144 Fibers Lf 1,000.000 0633- 1-310 Fiber Optic Cable, Install, Overhead Lf 1,000.000 0633- 1-320 Fiber Optic Cable, Install, Underground Lf 1,000.000 0633- 1-410 Fiber Optic Cable, Relocate, Overhead Lf 1,000.000 0633- 1-420 Fiber Optic Cable, Relocate, Underground Lf 1,000.000 0633- 1-610 Fiber Optic Cable, Remove, Overhead Lf 1,000.000 0633- 1-620 Fiber Optic Cable, Remove, Underground Lf 1,000.000 0633- 2- 31 Fiber Optic Connection, Install, Splice Ea 10.000 0633- 2- 32 Fiber Optic Connection, Install, Termination Ea 10.000 0633- 3- 11 Fiber Optic Connection Hardware, f&i, Splice Enclosure Ea 4.000 0633- 3- 12 Fiber Optic Connection Hardware, f&i, Splice Tray Ea 4.000 0633- 3- 13 Fiber Optic Connection Hardware, f&i, PreterminatedConnector AssemblyEa 4.000 0633- 3- 15 Fiber Optic Connection Hardware, f&i, PreterminatedPatch PanelEa 4.000 0633- 3- 16 Fiber Optic Connection Hardware, f&i, Patch Panel- FieldTerminatedEa 4.000 0633- 3- 17 Fiber Optic Connection Hardware, f&i, Connector Panel Ea 4.000 0633- 3- 51 Fiber Optic Connection Hardware, Adjust/Modify SpliceEnclosureEa 4.000 0633- 8- 1 Multi-Conductor Communication Cable, Furnish & Install Lf 1,000.000 0633- 8- 4 Multi-Conductor Communication Cable, Relocate Lf 1,000.000 0634- 4-152 Span Wire Assembly, f&i, Two Point, Diagonal Pi 10.000 0634- 4-153 Span Wire Assembly, f&i, Two Point, Box Or Drop Box Pi 10.000 0634- 4-600 Span Wire Assembly, Remove- Poles Remain Pi 10.000 0634- 5- 1 Fiberglass Insulator, Furnish & Install Lf 1,000.000 0634- 6- 1 Messenger Wire, Furnish & Install- Replace Existing Lf 1,000.000 0635- 2- 11 Pull & Splice Box, f&i, 13" x 24" Cover Size Ea 10.000 0635- 2- 12 Pull & Splice Box, f&i, 24" x 36" Cover Size Ea 10.000 0635- 2- 13 Pull & Splice Box, f&i, 30" x 60" Rectangular Or 36" RoundCover SizeEa 10.000 0635- 3- 11 Junction Box, Furnish & Install, Aerial Ea 10.000 0639- 1-112 Electrical Power Service, f&i, Overhead MeterPurchased By Contractor From Power CompanyAs 10.000 0639- 1-122 Electrical Power Service, f&i, Underground, MeterPurchased By ContractorAs 10.000 0639- 2- 1 Electrical Service Wire, Furnish & Install Lf 1,000.000 0639- 3- 11 Electrical Service Disconnect, f&i, Pole Mount Ea 4.000 0639- 3- 60 Electrical Service Disconnect, Remove- Pole Or CabinetTo RemainEa 4.000 0641- 1- 1 Guying Existing Concrete Strain Pole Ea 5.000 0641- 2- 12 Prestressed Concrete Pole, f&i, Type p-Ii Service Pole Ea 4.000 0641- 2- 13 Prestressed Concrete Pole, f&i, Type p-Iii Ea 4.000 0641- 2- 14 Prestressed Concrete Pole, f&i, Type p-Iv Ea 4.000 0641- 2- 15 Prestressed Concrete Pole, f&i, Type p-v Ea 4.000 0641- 2- 16 Prestressed Concrete Pole, f&i, Type p-Vi Ea 4.000 0641- 2- 17 Prestressed Concrete Pole, f&i, Type p-Vii Ea 4.000 0641- 2- 18 Prestressed Concrete Pole, f&i, Type p-Viii Ea 4.000 0641- 2- 60 Prestressed Concrete Pole, Complete Pole Removalpedestal/Service PoleEa 4.000 0641- 2- 70 Prestressed Concrete Pole, Shallow Pole Removal- Pole30` And GreaterEa 4.000 0641- 2- 80 Prestressed Concrete Pole, Complete Pole Removalpole30` And GreaterEa 4.000 0646- 1- 11 Aluminum Signals Pole, Pedestal Ea 20.000 0646- 1- 60 Aluminum Signals Pole, Remove Ea 20.000 0649- 26- 1 Steel Mast Arm Assembly, Remove, Pole Only- EntireFoundation RemainsEa 1.000 0649- 26- 3 Steel Mast Arm Assembly, Remove, Shallow FoundationboltOn AttachmentEa 1.000 0649- 26- 5 Steel Mast Arm Assembly, Remove, Deep Foundation- BoltOn AttachmentEa 1.000 0649- 26- 7 Steel Mast Arm Assembly, Remove, Remove Arm AndAttachments; Pole RemainsEa 1.000 0650- 1- 11 Vehicular Traffic Signal, Furnish & Install Aluminum, 1Section, 1 WayAs 15.000 0650- 1- 12 Vehicular Traffic Signal, Furnish & Install Aluminum, 1Section, 2-4 WayAs 15.000 0650- 1- 14 Vehicular Traffic Signal, Furnish & Install Aluminum, 3Section, 1 WayAs 15.000 0650- 1- 15 Vehicular Traffic Signal, Furnish & Install Aluminum, 3Section, 2-4 WaysAs 15.000 0650- 1- 16 Vehicular Traffic Signal, Furnish & Install Aluminum, 4Section, 1 WayAs 15.000 0650- 1- 17 Vehicular Traffic Signal, Furnish & Install Aluminum, 4Section, 2-4 WaysAs 15.000 0650- 1- 24 Vehicular Traffic Signal, Furnish & Install Polycarbonatew/Alum Top, 3 Section, 1 WayAs 15.000 0650- 1- 25 Vehicular Traffic Signal, Furnish & InstallPolycarbonate With Aluminum Top Section, 3 Section, 2-4 wAs 15.000 0650- 1- 26 Vehicular Traffic Signal, Furnish & Install Polycarbonatew/Alum Top, 4 Section, 1 WayAs 15.000 0650- 1- 29 Vehicular Traffic Signal, Furnish & Install Polycarbonatew Alumin, 5 Section Cluster, 1 WayAs 15.000 0650- 1- 34 Vehicular Traffic Signal, Furnish & InstallPolycarbonate, 3 Section, 1 WayAs 15.000 0650- 1- 35 Vehicular Traffic Signal, Furnish & InstallPolycarbonate, 3 Section, 2-4 WaysAs 15.000 0650- 1- 36 Vehicular Traffic Signal, Furnish & InstallPolycarbonate, 4 Section, 1 WayAs 15.000 0650- 1- 39 Vehicular Traffic Signal, Furnish & InstallPolycarbonate, 5 Section Cluster, 1 WayAs 15.000 0650- 1- 50 Vehicular Traffic Signal, Install As 15.000 0650- 1- 60 Vehicular Traffic Signal, Remove- Poles To Remain As 15.000 0650- 1- 70 Vehicular Traffic Signal, Relocate- Includes Removal AndReinstallationAs 15.000 0650- 2-102 Vehicular Signal Auxiliaries, Repair/Replace/Retrofitfurnish& Install, Backplate- Black With Reflect BorderEa 15.000 0653- 1- 11 Pedestrian Signal, Furnish & Install Led Countdown, 1WayAs 15.000 0653- 1- 12 Pedestrian Signal, Furnish & Install Led Countdown, 2WaysAs 15.000 0653- 1- 60 Pedestrian Signal, Remove Ped Signal- Pole/Pedestal ToRemainAs 15.000 0654- 1- 10 In Roadway Light Assembly, Furnish & Install- Ac Powered,Complete CrossingAs 2.000 0654- 1- 20 In Roadway Light Assembly, Furnish & Install- SolarPowered, Complete CrossingAs 2.000 0654- 2- 11 Rectangular Rapid Flashing Beacon, Furnish & Install- AcPowered, Complete Sign Assembly- Single DirectionAs 10.000 0654- 2- 12 Rectangular Rapid Flashing Beacon, Furnish & Install- AcPowered, Complete Sign Assembly- Back To BackAs 10.000 0654- 2- 21 Rectangular Rapid Flashing Beacon, Furnish & InstallsolarPowered, Complete Sign Assembly- Single DirectionAs 10.000 0654- 2- 22 Rectangular Rapid Flashing Beacon, Furnish & InstallsolarPowered, Complete Sign Assembly- Back To BackAs 10.000 0654- 2- 30 Rectangular Rapid Flashing Beacon, Install CompleteSign AssemblyAs 10.000 0654- 2- 40 Rectangular Rapid Flashing Beacon, Relocate CompleteSign AssemblyAs 10.000 0654- 2- 50 Rectangular Rapid Flashing Beacon, Adjust/Modify As 10.000 0654- 2- 60 Rectangular Rapid Flashing Beacon, Remove CompleteSign AssemblyAs 10.000 0654- 3- 10 Pedestrian Hybrid Beacon Assembly, Furnish & InstallComplete AssemblyAs 10.000 0654- 3- 60 Pedestrian Hybrid Beacon Assembly, Remove As 10.000 0660- 1-109 Loop Detector Inductive, f&i, Type 9 Ea 20.000 0660- 1-110 Loop Detector Inductive, f&i, Type 10 Ea 20.000 0660- 2-102 Loop Assembly, f&i, Type b As 20.000 0660- 2-106 Loop Assembly, f&i, Type f As 20.000 0660- 3- 11 Vehicle Detection System- Microwave, Furnish & InstallCabinet EquipmentEa 5.000 0660- 3- 12 Vehicle Detection System- Microwave, Furnish & Install,Above Ground EquipmentEa 5.000 0660- 3- 31 Vehicle Detection System- Microwave, Install- FdotFurnished Cabinet EquipmentEa 5.000 0660- 3- 32 Vehicle Detection System- Microwave, Install- FdotFurnished, Above Ground EquipmentEa 5.000 0660- 4- 11 Vehicle Detection System- Video, Furnish & Install CabinetEquipmentEa 5.000 0660- 4- 12 Vehicle Detection System- Video, Furnish & Install AboveGround EquipmentEa 5.000 0663- 1-111 Signal Priority And Preemption System, f&i, Optical,Cabinet ElectronicsEa 5.000 0663- 1-112 Signal Priority And Preemption System, f&i, Optical,DetectorEa 5.000 0663- 1-121 Signal Priority And Preemption System, Furnish AndInstall, Gps, Replace Cabinet ElectronicsEa 5.000 0663- 1-122 Signal Priority And Preemption System, Furnish AndInstall, Gps, DetectorEa 5.000 0665- 1- 11 Pedestrian Detector, Furnish & Install, Standard Ea 30.000 0665- 1- 12 Pedestrian Detector, Furnish & Install, Accessible Ea 30.000 0665- 1- 60 Pedestrian Detector, Remove- Pole/Pedestal To Remain Ea 15.000 0670- 4- 1 Intersection Control Beacon Controller Assembly,Furnish & InstallAs 5.000 0670- 5-110 Traffic Controller Assembly, f&i, Nema As 2.000 0670- 5-111 Traffic Controller Assembly, f&i, Nema, 1 Preemption As 2.000 0670- 5-112 Traffic Controller Assembly, f&i, Nema, 2 Preemption As 2.000 0670- 5-140 Traffic Controller Assembly, Furnish & Install Model 2070 As 5.000 0670- 5-141 Traffic Controller Assembly, Furnish & Install, Model2070, 1 PreemptionAs 5.000 0670- 5-142 Traffic Controller Assembly, Furnish & Install, Model2070, 2 PreemptionAs 5.000 0670- 5-300 Traffic Controller Assembly, Install As 2.000 0670- 5-400 Traffic Controller Assembly, Modify As 2.000 0670- 5-500 Traffic Controller Assembly, Relocate Controller WithCabinetAs 2.000 0670- 5-600 Traffic Controller Assembly, Remove Controller WithCabinetAs 10.000 0670- 5-700 Traffic Controller Assembly, Restore- Minor Repairs As 2.000 0678- 1-107 Controller Accessories, Replace Existing- Furnish AndInstall, Type 1 Time SwitchEa 5.000 0682- 1-133 Its Cctv Camera, f&i, Dome Enclosure - Non-Pressurized,Ip, High DefinitionEa 5.000 0684- 1- 1 Managed Field Ethernet Switch, Furnish & Install Ea 2.000 0685- 1- 11 Uninterruptible Power Supply, Furnish And Install, LineInteractiveEa 5.000 0695- 1- 1 Traffic Monitoring Site Vehicle Sensor-Non-Weight,Furnish & InstallEa 2.000 0695- 6- 12 Traffic Monitoring Site Inductive Loop Assembly, Furnish& Install, 2 LoopsEa 2.000 0695- 7-132 Traffic Monitoring Site Cabinet, Furnish & Install, Type 3,Pedestal MountEa 2.000 0695- 7-162 Traffic Monitoring Site Cabinet, f&i, Type 3, 2 Pane Back,Pedestal MountEa 2.000 0695- 7-600 Traffic Monitoring Site Cabinet, Remove Existing Cabinet Ea 2.000 0695- 8- 11 Traffic Monitoring Site Communications Modem Furnish &InstallEa 2.000
Details
Division 34 - Transportation, Transportation Signaling and Control Equipment, Roadway Signaling and Control Equipment, Traffic Signals, Traffic Control Equipment.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents