Similar Projects
Reported | 05/13/2021 12:00 AM |
Project Title | Quantity Purchase Award (QPA) Agreement for Guardrail Materials |
Physical Address | View project details and contacts |
City, State (County) | IN (Marion County) |
Category(s) | Heavy and Highway |
Sub-Category(s) | Highway Signs/Guardrails/Barriers |
Contracting Method | Competitive Bids. |
Project Status | Bidding |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | State Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | 1 1 Each WBGA 6’-3” W-Beam guardrail panels punched 1’-6-3/4" 2 1 Each WBGA 6’-3” W-Beam guardrail panels punched 3’-1-1/2" 3 1 Each WBGA 6'-3" W-Beam guardrail panels punched 6’-3” 4 1 Each WBGA 12’-6” W-Beam guardrail panels punched 1’-6-3/4” 5 77229 Each WBGA 12'-6" W-Beam guardrail panels punched 3'- 1-1/2" 6 100 Each WBGA 12'-6" W-Beam guardrail panels punched 6'-3" 7 1 Each WBGA 25'-0" W-Beam guardrail panelspunched 6'-3" 8 1 Each MGSA 12’-6” W-Beam guardrail panels punched 1’-6-3/4” 9 1 Each MGSA 12'-6" W-Beam guardrail panels punched 3'- 1-1/2" 10 1 Each MGSA 12'-6" W-Beam guardrail panels punched 6'-3" 11 1 Each MGSA 25'-0" W-Beam guardrail panels punched 6'-3" 12 23 Each TBGC 6’-3” Asymmetrical W-Beam to Thrie-Beam Transition 10 Gage 13 1 Each TWGT 6’-3” Asymmetrical W-Beam to Thrie-Beam Transition 14 1 Each TBGC 6’-3” Symmetrical W-Beam to Thrie-Beam Transition 15 1 Each TBGC 6’-3” Thrie-Beam guardrail panels punched 1’-6-3/4” 16 75 Each TBGC 12'-6" Thrie-Beam guardrail panels punched 1'-6-3/4" 17 3 Each WBGC W-Beam terminal connector 12 Gage 18 1 Each TBGC Thrie-Beam terminal connector 12 Gage 19 1 Each WBGC W-Beam backup plate 12 Gage 20 1 Each MTGR Thrie-Beam backup plate 12 Gage 21 1954 Each WBGC W-Beam curved terminal end 12 Gage 22 3 Each GCTA Flared W-Beam end section 12 Gage 23 1 Each GRET 1'-0" x 4'-0" 10 Gage steel plate for Guardrail End Treatment Type I 24 11 Each GRET Splice plate fabricated from WBeam section 10 Gage for Guardrail End Treatment Type I 25 102 Each CWGS 6" x 8" x 6'-0" CRT treated timber guardrail post 26 1 Each CWGS 5-1/2” x 7-1/2" x 3'-6-11/16" breakaway treated timber guardrail post 27 1 Each GCTA 5-1/2” x 7-1/2" x 3'-6-1/2" BCT treated timber guardrail post 28 1 Each GSA 6" x 8" x 6'-0" W-Beam treated timber guardrail post 29 1 Each MGSA W6 x 9 x 6’-0” W-Beam steel guardrail post 30 1 Each MGSA W6 x 9 x 7’-0” Guardrail Transition steel guardrail post, posts 1 thru 6 31 1 Each MGSA W6 x 9 x 6’-0” Guardrail transition steel guardrail post, posts 7 thru 12 32 1 Each MGSA W6 x 9 x 6’-0” Guardrail transition steel guardrail post, posts 13-17 33 6 Each Guardrail Post, Wood Type W5 34 1 Each TTGP 10” x 10” x 6’-0” W1 treated timber guardrail post 35 1 Each TTGP 8” x 8” x 6’-0” W2 treated timber guardrail post 36 1 Each TTGP 8” x 8” x 6’-0” W3 treated timber guardrail post 37 2 Each TTGP 8” x 8” x 6’-0” W4 treated timber guardrail post 38 1 Each WBGC W6 x 9 x 7’-0” steel guardrail po st 39 1 Each TTGB W6 x 9 x 7’-0” steel guardrail post, posts 1 thru 7 40 1 Each TTGB W6 x 9 x 7’-0” steel guardrail post, posts 8 thru 10 41 1 Each CWGS 6" x 8" x 1’-2" treated timber block 42 1 Each MGSA 6" x 8" x 1’-2" W-Beam treated timber blockout for steel guardrail post 43 1 Each MGSA 6" x 8" x 1’-2" W-Beam treated timber blockout for timber guardrail post 44 1 Each MGSA 6" x 1’-0" x 1’-7" Thrie-Beam treated timber blockout 45 1 Each MGSA 6" x 1’-0" x 1’-7" Guardrail Transition treated timber blockout, posts 1 thur 12 46 1 Each MGSA 6" x 1’-0" x 1’-2" Guardrail Transition treated timber blockout, posts 13 thru 17 47 1 Each MGSA 6" x 1’-0" x 1’-2" Thrie-Beam treated timber blockout for timber guardrail post 48 3238 Each WBGC 6" x 8" x 1’-2-1/4" treated timber blockout Type A 49 1 Each WBGC 4" x 7-3/4" x 1’-2" treated timber blockout Type B 50 1 Each MGSA 6" x 8" x 1’-2" W- Beam composite blockout for steel guardrail post 51 57 Each MTGR W14 x 22 x 1’-5” thrie beam, blockout, steel 52 1 Each TTGB TS7 x 4 x 3/16“ thrie beam blockout, steel, posts 1 thru 7 53 1 Each TTGB TS7 x 4 x 3/16“ thrie beam blockout, steel, post 8 54 57 Each TTGB TS7 x 4 x 3/16“ thrie beam blockout, steel, posts 9 and 10 55 20 Each TTGP 6” x 8” x 1’-10-1/2“ treated timber block B1 56 1 Each TTGP 6” x 8” x 1’-10-1/2“ treated timber block B2 57 22 Each TTGP 6” x 8” x 1’- 2“ treated timber block B3 58 1 Each MGSA 5/8" x 10" button head bolt 4” min. thread length 59 1 Each MGSA 5/8" x 1’-6" button head bolt 4” min. thread length 60 2000 Each WBGC 5/8" x 1-1/4" button head bolt full length thread 61 10 Each WBGC 5/8" x 2" button head bolt 1-1/2” min. thread length 62 1 Each WBGC 5/8" x 8-1/2" button head bolt 1- 3/4” min. thread length 63 1 Each WBGC 5/8" x 1’-6" button head bolt 2-1/2” min. thread length 64 1 Each WBGC 5/8" x 2’-1" button head bolt 2” min. thread length 65 6000 Each MGSA 5/8" heavy hex nut with 1” dia. x 1/16” recess both sides 66 1 Each WBGC 1-3/4" dia.flat steel washers for 5/8” bolt 67 1 Each WBGC 3/16" x 1 3/4" x 3" rectangular plate washer with 11/16" x 1" slot 68 7 Each Guardrail, Transition, Type TGB 69 324 Each Guardrail post, bracket, galvanized 14” |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |