Similar Projects
Fire Sprinkler and Fire Suppression Services
Term Contract
Bidding
Salt Lake City, UT

Southwest Technical College Student Services Remodel
Renovation, Term Contract
Bidding
Cedar City, UT 84720

La Verkin Elementary School Fire Sprinklers
Post-Bid
La Verkin, UT 84745

Fire Alarm Replacement
Post-Bid
Nephi, UT 84648

DFCM Construction - State Hospital Rampton 2 and Forensics Fire Alarm Upgrades
Results
$300,000 est. value
Provo, UT 84606

Bountiful High School Fire Alarm Upgrade
Results
$250,000 to $450,000 est. value
Bountiful, UT 84010

Replace Fire Suppression System at Fish Springs National Wildlife Refuge, UT
Post-Bid
$25,000 to $100,000 est. value
Ibapah, UT

SLCC TRC TB Corridor Ceiling and Fire Sprinkler Upgrade
Results
$990,000 est. value
Salt Lake City, UT 84123

Pioneer Museum Fire Alarm Upgrade
Post-Bid
Salt Lake City, UT

DFCM Construction-UNG Camp Williams Deluge System
Results
$207,000 est. value
Bluffdale, UT 84065

GTI Annex, Fire Sprinkler Project
Post-Bid
Salt Lake City, UT 84115

Construction: Westbrook Elementary, Fire Alarm Upgrade
Results
Less than $100,000 est. value
Taylorsville, UT 84129

Fire Alarm System Inspections
Post-Bid
Huntington, UT

Westpointe SSB Fire Suppression System Installation
Results
Less than $250,000 est. value
Salt Lake City, UT 84116

Gamewell Fire Alarm System
Term Contract
Results
West Jordan, UT

Last Updated 06/23/2021 09:41 AM
Project Title

North Park Elementary CO Detection and Fire Alarm Upgrade

Physical Address View project details and contacts
City, State (County) North Logan, UT 84341   (Cache County)
Category(s) Single Trades
Sub-Category(s) Fire Protection
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Addition of new CO detectors; relays for shutdown of AHU’s, swamp coolers and furnaces; power supplies; blue strobe notification device and fire alarm system devices in the North Park Elementary School. The existing fire alarm control panel is a Notifier 3030 panel and will communicate with the existing and new proposed CO detection and fire alarm devices. The CO detectors to be added will have a local sounder alarm for the space where CO is detected and the blue strobe in the office area will activate to notify personnel that CO has been detected. New 24v power circuits are to be ran in conduit from the added power supplies to each new CO detector base. New SLC (initiating) circuits are to be ran in conduit to the new CO detectors, smoke/heat detectors, monitor modules and control modules. New notification circuits are to be ran in conduit for the new blue strobe in the main office area and for added fire alarm horn strobes/strobes. Fire alarm relays will be programmed for shutting down the respective AHU’s or furnaces when CO is detected via the thermostat for each unit. Removal of select devices throughout the school is required per the design.

Details

Division 21 - Fire Suppression.
Division 28 - Electronic Safety and Security, Fire Detection and Alarm.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents