Reported | 08/15/2020 12:00 AM |
Project Title | Fire Extinguisher Inspection, Maintenance and Replacement Services |
Physical Address | View project details and contacts |
City, State (County) | Washington, DC 20002 (District of Columbia County) |
Category(s) | Single Trades |
Sub-Category(s) | Fire Protection |
Contracting Method | Competitive Bids. |
Project Status | Bidding |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | State Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The Contractor shall perform tasks that include, but are not limited to, the following: 1. Check that unit is properly hung with the proper manufacturer's hanger. 2. Remove the extinguisher from its hanger. 3. Check the gauge pressure. 4. Check the condition of the gauge and its compatibility with the extinguisher. 5. Check the weight of the extinguisher. 6. Check that the last hydro-test test date is within code requirements and if not, perform hydro-static testing. 7. Check the last 6-year maintenance inspection for compliance, if applicable. 8. Check the last 12-year maintenance inspection for compliance, if applicable. 9. Check the valve and shell for damage or corrosion. 10. Remove the hose and inspect it for cracks or splits. 11. Check the hose threads for signs of wear 12. Perform conductivity test on hose, per NFPA 10 13. Check the condition of the discharge horn. 14. Check for obstructions that interfere with accessibility of the extinguisher. 15. Break the extinguisher seal and remove the locking pin. 16. Check the upper and lower handles. 17. Replace safety disk, if necessary. 18. Verification of service collar, replace if necessary. 19. Replace O-ring, if necessary. 20. Replace the locking pin and reseal the extinguisher. 21. Check the valve opening for powder or any foreign matter. 22. Refill extinguishers, if needed. 23. Empty & recharge all stored pressure-loaded stream fire extinguishers. 24. For dry extinguishers, fluff the powder by turning the unit. 25. Clean the extinguisher shell with spray cleaner. 26. Return the hose to its proper position. 27. Check the condition of the hose/horn retention band at the side of the extinguisher. 28. Check that the unit's classification is properly identified with the appropriate decal. 29. Check that the operating instructions are clean and legible. 30. Tag the extinguisher properly. 31. Survey the hazard area to verify that the unit classification corresponds with the hazard. 32. Check that the unit is properly located within the normal path of travel, at a conspicuous height. 33. Check that the unit is visible and unobstructed. 34. Insure HMIS label is in place and legible. 35. Replace the extinguisher on its hanger 36. Compile a detailed report of the inspection and provide a legible written copy to the Program Manager. |
||||
Details |
|
||||
Bidder's List | View project details and contacts | ||||
Prospective Bidders | View project details and contacts | ||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |