Similar Projects
Walk-In Cooler/Freezer Combo
Alteration
Bidding
San Antonio, TX

Boiler Replacement at Metzger Middle School
Alteration
Bidding
San Antonio, TX 78244

Lighting, Mechanical and Fire Alarm Upgrades at Various Campuses
Post-Bid
Less than $397,000 est. value
San Antonio, TX 78250

ADC Domestic Pumps and Water Softener Tower A, B and C Project
Infrastructure, Alteration
Post-Bid
San Antonio, TX 78207

Water Softener Repair Services
Results
San Antonio, TX 78229

Annual Contract for Maintenance and Inspection of Boilers
Term Contract
Results
San Antonio, TX 78212

Lighting, Mechanical and Sound System Upgrades at Coke R. Stevenson and Katherine Stinson Middle School
Alteration
Post-Bid
San Antonio, TX 78254

Bubble Flow Meter System
Results
Less than $58,568 est. value
San Antonio, TX 78249

B7429 Boiler Replacement
Term Contract
Post-Bid
San Antonio, TX 78236

SASH/SSLC Boiler Inspections
Term Contract
Results
Less than $300,000 est. value
San Antonio, TX 78223

Esser Mechanical Upgrades at Katherine Stinson Middle School
Alteration
Post-Bid
$6,900,000 est. value
San Antonio, TX 78249

Boiler Replacement for Neal Elementary School
Results
San Antonio, TX 78201

Annual Contract for Boiler Inspections, Maintenance, and Repair Services for Other Locations - BESD
Term Contract
Results
$325,000 est. value
San Antonio, TX

Madonna Apartments Natural Gas Systems, Boiler Room & Parking Lot Improvements
Alteration
Results
San Antonio, TX 78216

J046--New - STX Water Softener Re-Bedding
Term Contract
Results

Last Updated 03/28/2022 09:03 AM
Project Title

Public Works Building Boiler Replacement

Physical Address View project details and contacts
City, State (County) San Antonio, TX 78214   (Bexar County)
Category(s) Single Trades
Sub-Category(s) Mechanical
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $57,020
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Demo existing (2) Lochinvar boilers Input Rating 285,000 BTU Housekeeping pad needs to be measured by vendor Condensing boilers have PVC Stacks and can be reconnected Install new (2) Raypak condensing boilers Modify house keeping pad as required Reconnect intake and exhaust flue to existing Replace flow switch Provide all permitting and inspections as required Disconnect and reconnect electrical as required Modify and connect gas and heating water piping required Reinsulate heating water as required

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Heating Boilers.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents