Similar Projects
Chiller Replacement - Release on or about April 9, 2021.
Design
$250,000 to $500,000 est. value
Beltsville, MD

Remove and Replace a Trane Rooftop Unit
Term Contract
Bidding
Beltsville, MD 20705

NMIC-1 Replace 4 Chillers and Controls/Install Chiller Catwalks Project, National Maritime Intelligence Center, Suitland, Maryland
Post-Bid
$10,000,000 to $25,000,000 est. value
Suitland, MD

RGH Air Condition Unit Replacement
Post-Bid
Laurel, MD 20707

J.E. Proctor Building Chiller Replacement
Results
Bowie, MD 20715

Croom High School HVAC Modernization
Results
Less than $1,700,000 est. value
Cheltenham, MD 20623

HVAC Preventative Maintenance and Service
Post-Bid

Thurgood Marshall Library Cooling Tower Replacement
Results
Bowie, MD 20715

Dust Collection Unit
Post-Bid
Andrews Air Force Base, MD 20762

Recommissioning (ReCx) Repairs Building: BARC 052 Controls
Results
$25,000 to $100,000 est. value
Beltsville, MD 20705

BARC MCquay Range #2 Chiller
Post-Bid
Beltsville, MD 20705

BARC - Overhaul Building 010A Chiller #2
Results
Beltsville, MD 20705

HVAC System Replacement for the 6000- Series
Post-Bid
Greenbelt, MD 20770

Dust Collection Unit
Results
MD 20762

Water Treatment Service Contract
Post-Bid
College Park, MD 20742

Reported 05/28/2021 12:00 AM
Project Title

Replace the Existing Steam Fired Hot Water Generator, at Bldg. #B006

Physical Address View project details and contacts
City, State (County) Beltsville, MD 20705   (Prince Georges County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value $25,000 to $100,000
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Remove and replace the existing Domestic Water Heater, piping and other accessories. Procure and install a new Steam to Hot Water Heater which shall include: hot water heating supply piping, re-circulated hot water heating piping and associated fittings. This shall include supplying and installing schedule 40 black steel pipe, fittings, shut off valves/isolation valves elbows, thermostat, insulating the pipes with pipe insulation. The Contractor shall restore damaged floors, walls and ceiling system to their original condition affected by the Description of Work and cleanup job site. The existing Steam Heat Exchanger system shall remain and reused.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents