Similar Projects
Boiler Plant Upgrades
Renovation, Alteration
Design
$100,000 to $250,000 est. value
Bath, NY 14810

Rehabilitate Elevators, Buildings 4 and 5 - HVAC
Infrastructure
Bidding
$50,000 to $100,000 est. value
New York, NY 10033

Fire Suppression Systems
Term Contract, Alteration
Bidding
Manhattan, NY

HVAC Removal and Replacement
Post-Bid
Corning, NY 14830

Installation and Integration of Needlepoint Bipolar Ionization in All HVAC Systems
Post-Bid
Chappaqua, NY 10514

Re-Pipe Condensate Line at B-35
Results
$25,000 to $100,000 est. value
Watervliet, NY 12189

Z--HOFR 217048/227558 Rehabilitation of the Roosevelt
Results
$1,000,000 to $5,000,000 est. value
Hyde Park, NY

Packaged Terminal Air Conditioner (PTAC) Units
Term Contract, Alteration
Bidding
Stony Brook, NY

HVAC Services
Post-Bid
Cortlandt Manor, NY 10567

Repair Make-Up Air Units, Bldg 115
Results
$25,000 to $100,000 est. value
Watervliet, NY

UH Lobby Air Curtain Replacement
Alteration
Bidding
Syracuse, NY 13210

Purchase of Heat Pumps
Term Contract
Post-Bid
Canandaigua, NY 14424

Merritt Pool AHU Replacement
Results
Geneseo, NY 14454

Renovate Sports Arena Ice Rink Refrigeration System at Buffalo State College
Alteration
Bidding
Buffalo, NY 14222

Albany Community Partnership Heating Systems
Post-Bid
Albany, NY 12206

Reported 11/23/2021 12:00 AM
Project Title

CUNY Brooklyn College West Quad HVAC Upgrade (Energy Performance)

Physical Address View project details and contacts
City, State (County) Brooklyn, NY 11210   (Kings County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Accepting Qualifications
Bids Due View project details and contacts
Estimated Value $1,500,000 to $2,000,000
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Outside air (OA), return air (RA), and spill air (SA) for air handling units (AHUs) 4-1 through 4-8 will be replaced with leak-proof opposed-blade air dampers. Re adjust and re-configure actuators on chilled water and steam valves (for AHU-4-1 through AHU-4-8) to seat properly. Replace steam valve on AHU-4-3. Replace variable frequency drive (VFD) on return fan RF-4-5a serving AHU-4-5. Replace bearings on return fan RF-4-5b and replace the fan VFD. Replace bearings on the return fan RF-4-6. Provide access panels in ductwork as indicated on drawings. Replace VAV-4-9. Replace actuators, recalibrate pick-up gains for air flow, and restore VAV’s 1-3 and 1-4 to full operating condition. Repair the leak in the supply air ductwork from AHU-4-4 as indicated on drawings. Provide VFDs for AHU-4-1 supply and return fans. Provide VFDs for AHU-4-4 supply and return fans. Provide VFDs for AHU-4-8 supply and return fans. Service-Disabled Veteran-Owned Business Contracting Goal: 6%

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents