Similar Projects
Last Updated | 11/10/2020 04:10 PM |
Project Title | 35-X165541 Model 8812 Equipment Shelter |
Physical Address | View project details and contacts |
City, State (County) | PA (Dauphin County) |
Category(s) | Commercial |
Sub-Category(s) | Warehouse/Storage |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Mobile 8’x12 Air Monitoring Instrument Shelter with Workbench Shelter components as follows: 1. Model 8812 Equipment shelter; Int. dimensions 94 ½” (92”)H x 92”W x 141”LG; Clear alum. exterior floor & roof, light tan alum. exterior walls; Slightly sloped roof; Light tan alum. interior ceiling & walls and industrial floor tiles; Insulation R12 (2”); Qty: 4 lift/tie down rings; Qty: 2 alum. skids w/ tie-down shoes; Qty: 1 – 36”W x 80”H entrance door with cam type door lock, hydraulic door closer; Unit prewired and temperature controlled w/ 12,000 Btu window type air conditioner, 120V, 60Hz & 3000W, 240V base board heat, automatic switch-over thermostat, interior outlets & lights; 100A, 240/120V, 1?, 60Hz power panel, 20 circuit capacity PTIONS AND ACCESSORIES: 2. Adjustable leveling tie down pads (8”sq.) on each shelter bottom corner, total max. adjustment: 2 1/2” (set of 4) 3. Large jack corner pockets only (to move shelter with EKTO trailer)(set of 4) 4. OSHA-type roof guard rails w/ kick plates & roof access ladder 5. Safety / anti-climb gate over roof access ladder 6. Bulkhead, dish type w/ Qty: 1 – 1” PVC elbow & Qty: 6 Swagelok fittings 7. Exterior outlets, GFI, 20A, 120V (set of 2) 8. Fire extinguisher, 5#, type ABC 9. 100A, 240/208V shunt main breaker and thermostat (attic – high temp) 10. Lightning surge arrestor (GE Tranquell), 650V 11. Workbench, 30”D x 141”W overall 12. Grommet feed-throughs in workbench (set of 5) 13. 10 Meter alum. tower, commercial crank-up type, 70 MPH rating with special roof storage configuration & pivot “ears” on roof edge (per spec) 14. Anti-climb plates over exposed tower sides 15. Glass sampling train and manifold (as specified |
||||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||
Project Documents |
![]() Engineered Spec Sheet ![]() Architectural Plans ![]() Other Documents |