Similar Projects
Automatic Doors Maintenance
Term Contract
Bidding
Wayne, MI

Overhead Door Replacement Project
Post-Bid
Detroit, MI 48211

Pedestrian Doors Service, Inspections,Parts, Repairs, Preventive Corrective Maintanance
Term Contract
Post-Bid
Detroit, MI

Lap Pool Tile Baseboard and Windowsill Replacement
Results
Livonia, MI 48154

Protective Glass for 2nd Floor at Wyandotte City Hall
Results
Wyandotte, MI 48192

Doors, Frames and Hardware
Post-Bid
Detroit, MI 48226

Overhead Door Assessment, Repair and Replacement Services
Results
Detroit, MI 48226

Window Blinds for Highland Park City Hall
Post-Bid
Highland Park, MI

Taylor Sportsplex Exterior Door
Results
Taylor, MI 48180

Glass Repair and Replacement
Term Contract
Post-Bid
Detroit, MI 48226

Window Glass Replacement
Results
Taylor, MI 48180

Door Replacement at the Henry Ford Centennial Library
Post-Bid
Dearborn, MI 48126

Window Leak Repair
Results
Detroit, MI

Fire House Bay Doors and Opener-Fire/C.E .Raines
Post-Bid
Riverview, MI 48193

Summit Door Replacement
Results
Canton, MI 48188

Reported 12/01/2021 12:00 AM
Project Title

WCCCD Curtis L. Ivery Downtown Campus Interior/Exterior Door Replacement Project

Physical Address View project details and contacts
City, State (County) Detroit, MI   (Wayne County)
Category(s) Single Trades
Sub-Category(s) Windows/Doors
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

1. Base bid to include removal, proper disposal, supply and installation of the new Interior/Exterior Door, frames and hardware. 2. Replace all denoted Existing Exterior Doors, Frames, Hardware and Accessories Complete. 3. The new exterior and interior doors and frames shall be products of one of the listed manufactures (Ceco, Mesker, Steelcraft, Pioneer-Detroit). Door Hardware to be by Von Duprin. 4. The new interior steel frames shall be 18 gauge and exterior frames to be 16 gage. 5. Refer to drawings for the location of door and frames to be replaced, contractor to field verify all final dimensions to adhere to existing opening. 6. Contractor is responsible for providing and install all new glazing specified. 7. Contractor is responsible for providing new key and locks to newly install cylinders. 8. Electrical Power to the Automatic ADA Door Openers shall be provided by WCCCD. All installations and final electrical connections are the responsibility of the Contractor. 9. A Mortise Cylinder Lock is to be provided on all entrance doors and specified doors. 10. All work must be performed in strict accordance with applicable codes and ordinances. It is the responsibility of the contractor to familiarize themselves with the code requirements and perform all work accordingly. 11. All existing door, frames and related materials to be removed and disposed of legally. 12. Remove and reinstall existing ADA Door Opener to be fully operational. 13. Contractor is to provide their own dumpster, location for dumpster will be provided by the owner. 14. Shop Drawing and Project Manager approval of shop drawings are required for all finished materials prior to commencing work.

Details

Division 08 - Openings, Doors and Frames, Windows.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents