Similar Projects
Rocky Creek WWTP Upgrades
Post-Bid
$650,000 est. value
McCormick, SC

Waste Water Treatment Plant
Post-Bid
Charleston, SC 29404

Lower Berkeley WWTP Aeration System Improvements
Renovation, Demolition
Results
Goose Creek, SC 29445

Water and Wastewater Statewide Maintenance - Tyger River Aerator Replacement
Results
$90,000 to $125,000 est. value
Enoree, SC 29335

Sewage Works Building Upfit
Construction
Greenville, SC 29607

Wastewater Treatment Plant Sludge Dewatering And Clarifier Upgrades
Post-Bid
$1,800,000 est. value
Bishopville, SC

Broad River WWTP Process Systems Upgrade Project
Results
Columbia, SC 29204

Schwartz Wwtp Digester Blower Motor #1
New Construction, Alteration
Post-Bid
Myrtle Beach, SC 29575

Brunson WWTP Upgrade
Results
Hampton, SC 29924

Final Settling Tanks - Drive Improvements Project
Renovation
Post-Bid
Charleston, SC 29412

Waccamaw Neck WTP Filter Media Replacement
Results
Less than $241,085 est. value
Pawley's Island, SC 29585

2020 West Alexander and Wilson Creek WWTP Improvements for the Headworks, Intermediate Pump Station, and Screw Pump Station
New Construction
Post-Bid
Greenwood, SC

Wastewater Treatment SVCS-Hunting Island
Results
Saint Helena Island, SC 29920

Brooks Street Wastewater Treatment Plant Lime Feed System and Other Improvements
Renovation
Post-Bid
Edgefield, SC 29824

Perforated Plate Filter Screen and Screen Wash Press
Results
North Augusta, SC 29842

Reported 01/08/2022 12:00 AM
Project Title

Conway Wastewater Treatment Plant Screen

Physical Address View project details and contacts
City, State (County) Conway, SC 29527   (Horry County)
Category(s) Sewer and Water
Sub-Category(s) Sewage Treatment Plant
Contracting Method Competitive Bids.
Project Status Request for Proposals (RFPs)
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Scope: The Project includes to purchase and delivery of one (1) screen for its Conway WWTP. The Conway screen average daily flow design is 4 MGD but must be able to handle 2.5 flow peaking factor equaling 10 MGD. Max head loss at 25% binding factor for the Conway Screen is 8.5 inches. Providers shall verify max head loss. The screening channel measures 24 inches wide and 51 inches deep. The screen shall be installed in the existing channel, without significant modifications or using the bypass channel. The screen will be used as a primary screen and must be able to handle all screenings. Screen must be at least ASTM A380 passivated 304 SS with the price option of upgrading to ASTM A380 passivated 316 SS, if available.

Details

Division 46 - Water and Wastewater Equipment, Screening Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents