Similar Projects
On-Call Small Electrical Contractor Projects
Term Contract
Results
Less than $200,000 est. value
College Park, MD

Switch Gear Preventative Maintenance
Results
Cheverly, MD 20785

On-Call Repair, Critical Electrical and Mechanical Services for Water and Wastewater Treatment Systems
Results
Bowie, MD 20716

Theatrical Lighting, Theatrical Sound and Theatrical Riggings, Installation, Repairs, Parts and Associated Services for Pre-Qualified Vendors Under BCPS
Results
Greenbelt, MD 20770

Switchgear and Boiler Room Panelboard Replacements
Results
Brandywine, Chillum, Clinton, Fort Washington, Suitland, Upper Marlboro, MD 20744

Design, Installation and Maintenance-Solar Photovoltaic System at DPW Landscaping Garage Roof
Post-Bid
College Park, MD 20740

Rays on the Roof
Pending Verification
$350,000 est. value
Greenbelt, MD 20770

LED Line Lights
Post-Bid
Beltsville, MD

Retrofit Environmental Growth Chambers in Buildings 010B, Replacing HID & Fluorescent Lights with LED Lights
Results
Beltsville, MD 20705

Uninterruptible Power Supply (UPS) Batteries and Installation
Results
Adelphi, MD 20783

Generator Preventive and Corrective Services
Term Contract
Post-Bid
Laurel, MD 20707

MD 355 Crossing - Communication and Electrical Switches and Installation
Post-Bid
Less than $250,000 est. value
Glenn Dale, MD 20769

Electrical Maintenance, New Installation and Repair
Term Contract
Post-Bid
Less than $50,000 est. value
Greenbelt, MD

Turnkey Solar Power System
Bidding
Hyattsville, MD

Electrical Maintenance Marlboro Maintenance Facility
Bidding
$50,000 est. value
Upper Marlboro, MD

Last Updated 01/03/2020 03:12 PM
Project Title

Reconnect/Install/Disconnect a Generator

Physical Address View project details and contacts
City, State (County) Beltsville, MD 20705   (Prince Georges County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Statement of Work - for the following Electrical Contracting Services - Reconnection of a 500kw generator at bldg. 310a in Beltsville, Maryland 20705 - and a - disconnection of a temporary - aksa marathon generator - that's trailor generated. The contractor shall provide all labor, material, equipment, and service required to complete the installation of a government owned 500 KW Cummins Power Generation generator - model # DFED-5568669 serial# J02042060 spec. G) located at the United States Department of Agricultural 10300 Baltimore Avenue Beltsville Maryland 20705 building 310 East campus. The contractor shall install/re-strap the Cummins Power Generation generator which will supply building 310 with an output voltage of 277/480 volts for emergency power. The contractor shall replace the existing 1200 amp circuit breaker with new 600 amp circuit breaker located in the main electrical panel in building 310. The contractor shall modify and or extend the existing conduits and pad to make all re-connections for the Cummins Power Generations generator to building 310. The contractor shall disconnect the AKSA Marathon AP-EPAP512 trailer mounted temporary generator from building 310. Once all of the connection have been properly disconnected the contractor will move the AKSA Marathon generator form building 310 to storage area located behind building 426A about 1/4 mile away. The contractor will be responsible for testing and startup of the government owned Cummins Power Generation generator emergency system to ensure proper operations with the generator as well as the switch gear while the government Contracting Officer Reprehensive (COR) is present.

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents