Similar Projects
Lighthouse Park Maintenance Building
Alteration
Bidding
New Haven, CT 06510

Toquam Magnet Elementary School Partial Roof Replacement Phase II
Alteration
Bidding
$2,000,000 est. value
Stamford, CT 06907

East Litchfield Roof Replacement
Post-Bid
Litchfield, CT 06759

Tasker Admissions Building Roof Restoration
Post-Bid
$424,440 est. value
Mansfield, Storrs, CT 06269

Roof Replacement at East School
Results
New Canaan, CT 06840

Chemistry Building Roof Snow Guards
Results
Tolland, CT 06269

Stowe Village Roof Replacement Phase II
Alteration
Bidding
Hartford, CT 06120

Roofing
Post-Bid
Glastonbury, CT 06033

South Windsor High School Annex Roof Replacement
Results
South Windsor, CT 06074

White Building Roof Replacement
Alteration
Bidding
$600,000 est. value
Storrs, CT

Roofing Repair and Maintenance
Post-Bid

Partial Roof Replacement for South Windsor High School
Results
South Windsor, CT 06074

Voluntown Public Library - Remove and Replace Roof and Gutters
Alteration
Bidding
$400,000 est. value
Voluntown, CT 06384

Roof Replacement - New Canaan High School
Post-Bid
New Canaan, CT 06840

Western Hills Golf Course Roof Repair Project
Results
Waterbury, CT 06708

Last Updated 04/20/2022 10:23 AM
Project Title

Alumni Residence Halls Roof Replacement

Physical Address View project details and contacts
City, State (County) Mansfield, Storrs, CT 06268   (Tolland County)
Category(s) Single Trades
Sub-Category(s) Roofing
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value Greater than $500,000
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Alumni Res Halls work includes Remove existing gravel-surfaced built-up roofing systems down to concrete/gypsum roof decks. Prepare and repair roof deck to receive new roofing system. Replace the roof with new vapor barrier, tapered insulation (where applicable), coverboard, and EPDM roof membrane. Increased insulation thickness is expected to meet current energy code requirements. Raise existing vent pipes and penetrations to accommodate increased roofing thicknesses. Provide additional blocking at all parapets to maintain existing height relative to increased roof thicknesses. Remove and replace parapet caps in all locations sloped toward the roof surface. Remove and replace roof overflow scuppers. Raise penetration curb heights to maintain eight (8)-inch minimum flashing height over new roofing. Remove and replace roof hatches. Remove and reinstall exhaust vents, and other associated equipment as required. Provide guardrails for serviceable equipment located near the roof edge. Remove and replace existing drain bowls and strainers. Connect to existing drain leaders. Remove and replace gutters and downspouts. Connect applicable downspouts to existing drain leaders. Remove and replace five (5) courses of brick at each penthouse level to access and remove the existing stainless-steel drip edges. Replace existing drip edges with stainless steel pan flashings including rear leg, end dams, and new through-wall membrane cavity flashing. Provide new termination assembly for the roof membrane. Coordinate new through-wall flashing height relative to new roofing. • Remove and replace roof access ladders. Coordinate height and installation with new roofing height and masonry restoration. Remove and replace roof access and mechanical penthouse doors. Raise threshold height to coordinate with new roofing height.

Details

Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents